Miroslaw Swiercz

Prof. Miroslaw Swiercz

Bialustok University of Technology, Faculty of Electrical Engineering
orcid

Research Focus & Metrics

Academic Career Length

32Years (1995-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2009 in Critical Care Medicine
Verified
Journal Article
Closed access
MSMaciej Swiat
Maciej Swiat
JWJohn Weigele
John Weigele
RHRobert W. Hurst
Robert W. Hurst
SKScott E. Kasner
Scott E. Kasner
MPMikolaj Pawlak
Mikolaj Pawlak
JKJaroslaw Krejza
Jaroslaw Krejza
To prospectively compare accuracies of transcranial color-coded duplex sonography (TCCS) and transcranial Doppler sonography (TCD) in the diagnosis of middle cerebral artery (MCA) vasospasm. Prospective blinded head-to-head comparison TCD and TCCS methods using digital subtraction angiography (DSA) as the reference standard. Department of Radiology in a tertiary university health center in a metropolitan area. Eighty-one consecutive patients (mean age, 53.9 +/- 13.9 years; 48 women). The indication for DSA was subarachnoid hemorrhage in 71 patients (87.6%), stroke or transient ischemic attack in five patients (6.2%), and other reasons in five patients (6.2%). The MCA was graded as normal, narrowed 50% using DSA. The accuracy of ultrasound methods was estimated by total area (Az) under receiver operator characteristic curve. To compare sensitivities of ultrasound methods, McNemar's test was used with mean velocity thresholds of 120 cm/sec for the detection of less advanced, and 200 cm/sec for the more advanced MCA narrowing. Angiographic MCA narrowing 50% in 10 of 135 arteries. Accuracy of TCCS was insignificantly higher than that of TCD in the detection of 50% narrowing, total Az for mean velocity being 0.83 +/- 0.05, 0.77 +/- 0.05, and 0.95 +/- 0.02, 0.86 +/- 0.08, respectively. Sensitivity of TCCS at commonly used threshold of 120 cm/sec for less advanced MCA spasm was significantly better than that of TCD at similar specificity, 55% vs. 39%, p = 0.038, whereas at a threshold of 200 cm/sec used for more advanced spasm, sensitivities and specificities of both methods were not different. The accuracy of TCCS and TCD is similar, but TCCS is more sensitive than TCD in the detection of MCA spasm. Sensitivity of both techniques in the detection of mild and more advanced spasm using 120 cm/sec and 200 cm/sec thresholds, respectively, is poor; however, a larger sample is required to increase precision of our sensitivity estimates.

12 April 2000 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
Miroslaw SwierczMiroslaw Swiercz
Miroslaw Swiercz
ZMZenon Mariak
Zenon Mariak
JKJ. Krejza
J. Krejza
JLJ. Lewko
J. Lewko
PSP. Szydlik
P. Szydlik

1 February 2002 in Journal of Neurosurgery
Verified
Journal Article
Closed access
ZMZenon Mariak
Zenon Mariak
JKJaroslaw Krejza
Jaroslaw Krejza
Miroslaw SwierczMiroslaw Swiercz
Miroslaw Swiercz
KKKazimierz Kordecki
Kazimierz Kordecki
JLJanusz Lewko
Janusz Lewko
The value of transcranial Doppler ultrasonography for the detection of middle cerebral artery (MCA) spasm has been asserted. None of the published studies, however, has adequately scrutinized the overall diagnostic accuracy of this procedure. There are only sporadic reports concerning the utility of transcranial color Doppler (TCCD) ultrasonography, although this method has been proved to be more precise. In this study the authors attempted to estimate the performance of TCCD ultrasonography in detecting MCA narrowing by using receiver operating characteristic (ROC) curve analysis, based on TCCD studies obtained in a relatively large, randomly selected population of patients.Transcranial color Doppler ultrasonography studies were obtained in 100 consecutive patients (54 men and 46 women ages 18-74 years, median age 50 years) routinely referred by neurosurgeons for intraarterial angiography. The M1 segment of the MCA was insonated using a 2.5-MHz probe via a temporal acoustic window, and angle-corrected flow velocities were obtained. Angiographically depicted vasospasm was graded as none, mild (< or = 25% vessel caliber reduction), and moderate to severe (> 25% vessel caliber reduction). The effectiveness of TCCD ultrasonography in diagnosing MCA spasm was evaluated by calculating the areas under the ROC curves (Az). Of the 200 MCAs examined, 173 were successfully visualized with the aid of TCCD ultrasonography. Mild vasospasm was angiographically diagnosed in 15 arteries and moderate-to-severe vasospasm in 28. The best-performing TCCD parameter for the detection of MCA narrowing was revealed to be peak systolic velocity. The Az value for moderate-to-severe vasospasm only was 0.93 and that for all vasospasms was 0.8. The best efficiency, that is, the optimal tradeoff between sensitivity and specificity in diagnosing vasospasms, was associated with a peak systolic velocity of 182 cm/second.The performance of TCCD ultrasonography in the diagnosis of advanced MCA narrowing is very good, and is acceptable for all vasospasms. The best-performing parameter was peak systolic velocity.

11 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
Miroslaw SwierczMiroslaw Swiercz
Miroslaw Swiercz
HMHalina Mroczkowska
Halina Mroczkowska
In the paper the usability of the Multiway PCA (MPCA) method for early detection of leakages in the pipeline system of a steam boiler in a thermal-electrical power plant is presented. A long segment of measurements of selected process variables was divided into a series of “batches” (representing daily recordings of normal behavior of the plant) and used to create the MPCA model of a “healthy” system in a reduced space of three principal components (PC). The periodically updated MPCA model was used to establish the confidence ellipsoid for the “healthy” system in the PC coordinates. The staff’s decision of the probable leak detection is supported by comparison of the current location of the operating point (on the “fault trajectory”) with the boundaries of the confidence ellipsoid. It must be emphasized that due to daily and seasonal changes of heat/electricity demands, the process variables have substantially greater variability than in the examples of batch processes studied in literature. Despite those real challenges for the MPCA method, numerical examples confirmed that the presented approach was able to foresee the leaks earlier than the operator, typically 3–5 days before the boiler shutdown. The presented methodology may be useful in implementation of an on-line system, developed to improve safety and maintenance of boilers in a thermal-electrical power plant.

12 April 2000 in Acta Neurochirurgica
Verified
Journal Article
Closed access
PDF file
ZMZenon Mariak
Zenon Mariak
Miroslaw SwierczMiroslaw Swiercz
Miroslaw Swiercz
JKJ. Krejza
J. Krejza
JLJ. Lewko
J. Lewko
TLT. Lyson
T. Lyson

1 January 2010 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
Miroslaw SwierczMiroslaw Swiercz
Miroslaw Swiercz
MSMaciej Swiat
Maciej Swiat
MPMikolaj Pawlak
Mikolaj Pawlak
JWJohn Weigele
John Weigele
RTRoman Tarasewicz
Roman Tarasewicz
JKJaroslaw Krejza
Jaroslaw Krejza