Achieving reliable electrical performance with stretchability and conformability is a key issue for wearable electronics. In this letter, we demonstrate an intrinsically stretchable temperature sensor element based on organic thin-film transistors (OTFTs). The OTFTs were characterized with respect to their temperature and strain dependence, and subsequently evaluated using differential readout circuit schemes. We considered two circuit variants to accommodate OTFTs with nominally positive or negative threshold voltages. Due to the strain suppression afforded by the differential readout, the intrinsically stretchable temperature sensor element achieves an inaccuracy within 1 °C with uniaxial strains from 0-30 %.
Organic solar cells based on poly[2,6-(4,4-bis-(2-ethylhexyl)-4H-cyclopenta[2,1-b;3,4-b′]dithiophene)-alt-4,7-(2,1,3-benzothiadiazole)] (PCPDTBT) and [6,6]-phenyl C71 butyric acid methyl ester (PC71BM) were fabricated by emulsion-based, resonant infrared matrix-assisted pulsed laser evaporation (RIR-MAPLE). Two different deposition modes, namely simultaneous deposition and sequential deposition, were investigated for fabricating bulk-heterojunction organic solar cells. This work demonstrates that the RIR-MAPLE sequential deposition mode provides precise ratio control for the fabrication of bulk-heterojunction organic solar cells.
In this work, an approach for enabling miniaturized, low-voltage hardware for active structural health monitoring (SHM) based on ultrasonic guided waves is investigated. The proposed technique relies on S-parameter measurements instead of time-domain pulsing and thereby trades off longer measurement times with lower actuation voltages for improved compatibility with dense complementary metal-oxide-semiconductor (CMOS) chip integration. To demonstrate the feasibility of this method, we present results showing the successful localization of defects in aluminum and carbon-fiber-reinforced polymer (CFRP) test structures using S-parameter measurements. The S-parameter measurements were made on benchtop vector network analyzers that actuate the piezoelectric transducers at output voltage amplitudes as low as 1.264 Vpp.
This paper investigates miniaturized hardware for active SHM based on ultrasonic guided-waves. The proposed approach relies on frequency-domain S-parameter measurements instead of time-domain pulsing and thereby trades off longer measurement times with lower actuation voltages for improved compatibility with dense CMOS chip integration. To demonstrate the feasibility of this approach, we show defect localization measurements for an aluminum plate using a benchtop vector network analyzer using 0 dBm (0.632 V ) actuation signals. The challenge of designing directional couplers in the 10 kHz – 10 MHz target frequency range of the system is discussed and ongoing work to address this challenge is presented.