The direct measurement of flexoelectric coefficients in epitaxial thin films is an unresolved problem, due to the clamping effect of substrates which induces a net strain (and hence parasitic piezoelectricity) in addition to strain gradients and flexoelectricity. Herein, we propose and demonstrate the use of van der Waals epitaxy as a successful strategy for measuring the intrinsic (clamping-free = flexoelectric coefficients of epitaxial thin films. We have made, measured, and compared and thin film capacitor heterostructures grown both by conventional oxide-on-oxide epitaxy and by van der Waals oxide-on-mica epitaxy, and found that, whereas the former is dominated by parasitic piezoelectricity, the response of the latter is truly flexoelectric. The results are backed by theoretical calculations of the film-substrate mechanical interaction, as well as by direct measurements that confirm the strain-free state of the films. van der Waals epitaxy thus emerges as powerful new tool in the study of flexoelectricity and, in particular, they finally allow exploring flexoelectric phenomena at the nanoscale (where strain gradients are highest) with direct experimental knowledge of the actual flexoelectric coefficients of thin films.
22 February 2022 in IEEE Transactions on Industrial Informatics
The high proliferation of electric vehicles has intensified the interdependency between traffic networks (TNs) and power distribution networks (PDNs). Accordingly, this article proposes a decentralized optimization framework for the multiarea optimal traffic-power flow (OTPF) problem, in which the models of PDNs and TNs are established separately in a distributed manner. A multistage distributionally robust optimization (MDRO) model is formulated for PDNs to address wind power uncertainty, with the introduction of a traffic assignment problem to describe the distribution of traffic flows in TNs. Furthermore, an improved alternative direction method of multipliers (I-ADMM) algorithm is developed to solve the multiarea OTPF problem. Numerical results from a three-area traffic-power coupled system demonstrate that the proposed MDRO model bears a cost $89.50 lower than that of the multistage robust optimization model, while the I-ADMM algorithm yields a solving time only one-third that of the traditional ADMM.
12 April 2023 in International Journal of Electrical Power & Energy Systems
Due to a lack of high and stable power supplies for large-scale online monitoring devices, the intelligent development of high voltage transmission lines has always been restricted. This paper presents a method for capacitive power tapping from an insulated shield wire of overhead high voltage transmission lines with tuning. A general equivalent model, which considers the influence of line sag and landform on the equivalent circuit parameters, is established. The calculated equivalent circuit parameters show good agreement with the field measured data obtained by a 220 kV single-circuit transmission line. In order to maximize the tap-off power, a nonlinear tuning method is proposed since linear tuning can cause an overvoltage problem, and a tuned reactor is developed. Based on the measured equivalent circuit parameters, an experiment platform is built in the laboratory to measure the tap-off power under different resistive loads. The experimental results indicate that the maximum power is about 900 W, which represents an improvement of 80% compared with the maximum power without tuning. Additionally, the tuned reactor shows good robustness to the perturbation of equivalent circuit parameters, which validates the effectiveness of the proposed power tapping method.
Donor doping can increase the dielectric constant of a material by several orders of magnitude due to induced space charge causing interfacial polarization. Giant dielectric properties and interface polarization are also both expected to greatly enhance the flexoelectric behavior of a material. In this work, a typical flexoelectric ceramic material, BaTiO3, was selected and donor doped using elemental Nb. Compared with the nominal BaTiO3 ceramic, the dielectric constant and flexoelectric coefficient of the Nb-doped BaTiO3 ceramics were significantly improved. The transverse flexoelectric coefficient of 0.3 mol. % Nb-BaTiO3 was found to increase to nearly 40 times the nominal value, reaching 387 μC/m. The results indicate that the giant dielectric response, and therefore the giant flexoelectric response, is the result of the combined effects of internal barrier-layer capacitance and surface barrier-layer capacitance. This study not only deepens the understanding of the semiconductor macro-dielectric effect and the flexoelectric mechanism caused by doping, but it also provides a feasible strategy for the design of giant dielectric/flexoelectric response materials and related devices with high dielectric constants and flexoelectric coefficients.
4 May 2022 in IEEE Transactions on Components, Packaging and Manufacturing Technology
Corona discharge occasionally occurs to the contact box of switchgear due to condensation under high humidity and pollution conditions, which may result in a switchgear insulation fault. In this article, we develop an experimental platform for the condensation of contact boxes in switchgear. A metallographic microscope is used to measure the size and distribution characteristics of dewdrops on the surface of the contact box under various temperature, humidity, and pollution conditions. A simulation model for the distribution of dewdrops is established using fractal theory, and the simulation results match the measured results well. The corona onset voltage is predicted and verified by the UV imager’s measurements by substituting the electric field distribution around the contact box with different dewdrops into the streamer inception criterion. The research results indicate that higher humidity and temperature differences result in a larger dewdrop and a shorter condensation formation time, resulting in a lower corona onset voltage. The effect law is similar under high pollution conditions, but the dewdrop is larger, the condensation formation time is longer, and the corona onset voltage is significantly lower than under clean conditions. As a result, high humidity and pollution conditions must be avoided during the operation of switchgear.