A uric acid (UA) electrochemical biosensor was constructed using ferrocene (Fc) decorated cuprous oxide (Cu2O) enhanced electro-active characteristics and covalently immobilized with uricase (UOx) on glassy carbon electrode (GCE). The electrochemical characteristics of the fabricated electrode was analysed by cyclic voltammetry, electrochemical impedance spectroscopy and differential pulse voltammetry (DPV). DPV studies revealed rapid response of fabricated electrode UOx/Fc/Cu2O/GCE towards UA in a wide concentration range of 0.1–1,000 μM with a sensitivity of 1.900 μA mM−1 cm−2and very low detection limit of 0.0596 μM. A very low magnitude Michaelis–Menten constant (Km) value was evaluated as 34.7351 μM which indicated the chemical attraction of the enzyme towards the UA was much higher. The developed biosensor was successfully applied to detect UA in human urine samples. Moreover, reproducibility and stability studies demonstrated the fabricated UOx/Fc/Cu2O/GCE biosensor had high reproducibility with a RSD of 2.8% and good reusability with a RSD of 3.2%. Specificity studies results showed the fabricated biosensor had strong anti-interference ability. The improved sensor performance was attributed to the synergistic electronic properties of Cu2O and Fc that provided enhances delectrocatalytic activity and electron transfer. The present biosensor can be extended for use in clinical settings.
1 September 2013 in Journal of the Chilean Chemical Society
<![CDATA[High performance liquid chromatography coupled with diode array detection (HPLC-DAD) was developed for the simultaneous determination of three bioactive components - chlorogenic acid, baicalin and forsythin - in traditional Chinese medicinal Shuanghuanglian preparations. The analytes were extracted successfully using 80% aqueous methanol for 15 min in an ultrasonic bath. The optical chromatographic separation conditions were performed on a Finnigan Surveyor HPLC system with an Agilent Zorbax ODS C18 (4.6x150 mm, particle size 5 ìçé ) at 30 ºC using a gradient elution program with a mixture of acetonitrile and 0.2% phosphoric acid (v/v) as mobile phase within 25 min. Method validation results were obtained through the generation of calibration curves with the mixed standard solutions and a standard addition method, regression equations revealed linear relationships (correlation coefficients 0.9965-0.9985) between the peak area and concentration of the three analytes. The average recoveries were 90-106% (n= 6) with standard deviation below 3.37%. The developed HPLC assay was specific and could be readily utilized for comprehensive evaluation of Shuanghuanglian preparations.]]>
Objective. To establish a method for analysis of microelements in five kinds of traditional Chinese medicine in high blood pressure medicinal food, mainly including manganese, cobalt, selenium, iron, magnesium, and other 15 elements. Methods. The samples were digested using a microwave digestion instrument through NHO3-H2O2 solution, and then, the elements were synthesized by inductively coupled plasma atomic emission spectrometry (ICP-AES). Results. The content of cobalt, manganese, zinc, copper, and nickel in the high blood pressure diet foods is higher, the RSD is between 0.005% and 4.82%, and the recovery rate ranges from 93.40% to 106.5%. The precision and recovery of the detection method are higher. Conclusion. The experiment result is better. Medicinal foods curing high blood pressure contain a number of micronutrients that are beneficial to the human body. This experiment provides some meaningful basis for the prevention and treatment of cardiovascular diseases such as hypertension.