Amar Basu

Prof. Amar Basu

Wayne State University, Detroit, MI 48202, USA
orcid

Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2017 in SLAS Technology
Verified
Journal Article
Open access
ABAmar Basu
Amar Basu
A digital assay is one in which the sample is partitioned into many small containers such that each partition contains a discrete number of biological entities (0, 1, 2, 3, …). A powerful technique in the biologist’s toolkit, digital assays bring a new level of precision in quantifying nucleic acids, measuring proteins and their enzymatic activity, and probing single-cell genotypes and phenotypes. Part I of this review begins with the benefits and Poisson statistics of partitioning, including sources of error. The remainder focuses on digital PCR (dPCR) for quantification of nucleic acids. We discuss five commercial instruments that partition samples into physically isolated chambers (cdPCR) or droplet emulsions (ddPCR). We compare the strengths of dPCR (absolute quantitation, precision, and ability to detect rare or mutant targets) with those of its predecessor, quantitative real-time PCR (dynamic range, larger sample volumes, and throughput). Lastly, we describe several promising applications of dPCR, including copy number variation, quantitation of circulating tumor DNA and viral load, RNA/miRNA quantitation with reverse transcription dPCR, and library preparation for next-generation sequencing. This review is intended to give a broad perspective to scientists interested in adopting digital assays into their workflows. Part II focuses on digital protein and cell assays.

8 March 2013 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
ABAmar Basu
Amar Basu
Emerging assays in droplet microfluidics require the measurement of parameters such as drop size, velocity, trajectory, shape deformation, fluorescence intensity, and others. While micro particle image velocimetry (μPIV) and related techniques are suitable for measuring flow using tracer particles, no tool exists for tracking droplets at the granularity of a single entity. This paper presents droplet morphometry and velocimetry (DMV), a digital video processing software for time-resolved droplet analysis. Droplets are identified through a series of image processing steps which operate on transparent, translucent, fluorescent, or opaque droplets. The steps include background image generation, background subtraction, edge detection, small object removal, morphological close and fill, and shape discrimination. A frame correlation step then links droplets spanning multiple frames via a nearest neighbor search with user-defined matching criteria. Each step can be individually tuned for maximum compatibility. For each droplet found, DMV provides a time-history of 20 different parameters, including trajectory, velocity, area, dimensions, shape deformation, orientation, nearest neighbour spacing, and pixel statistics. The data can be reported via scatter plots, histograms, and tables at the granularity of individual droplets or by statistics accrued over the population. We present several case studies from industry and academic labs, including the measurement of 1) size distributions and flow perturbations in a drop generator, 2) size distributions and mixing rates in drop splitting/merging devices, 3) efficiency of single cell encapsulation devices, 4) position tracking in electrowetting operations, 5) chemical concentrations in a serial drop dilutor, 6) drop sorting efficiency of a tensiophoresis device, 7) plug length and orientation of nonspherical plugs in a serpentine channel, and 8) high throughput tracking of >250 drops in a reinjection system. Performance metrics show that highest accuracy and precision is obtained when the video resolution is >300 pixels per drop. Analysis time increases proportionally with video resolution. The current version of the software provides throughputs of 2–30 fps, suggesting the potential for real time analysis.

18 August 2010 in Lab on a Chip
Verified
Journal Article
Closed access
PDF file
VTVarun Trivedi
Varun Trivedi
ADAnkur Doshi
Ankur Doshi
GKG. K. Kurup
G. K. Kurup
EEE. Ereifej
E. Ereifej
PVP. J. Vandevord
P. J. Vandevord
ABAmar Basu
Amar Basu
The desire to make microfluidic technology more accessible to the biological research community has led to the notion of “modular microfluidics”, where users can build a fluidic system using a toolkit of building blocks. This paper applies a modular approach for performing droplet-based screening, including the four integral steps of library generation, storage, mixing, and optical interrogation. Commercially available cross-junctions are used for drop generation, flexible capillary tubing for storage, and tee-junctions for serial mixing. Optical interrogation of the drops is achieved using fiber-optic detection modules which can be incorporated inline at one or more points in the system. Modularity enables the user to hand-assemble systems for functional assays or applications. Three examples are shown: (1) a “mix and read” assay commonly used in high throughput screening (HTS); (2) generation of chemically distinct droplets using microfractionation in droplets (µFD); and (3) in situ encapsulation and culture of eukaryotes. Using components with IDs ranging from 150 µm to 1.5 mm, this approach can accommodate drop assays with volumes ranging from 2 nL to 2 µL, and storage densities ranging from 300 to 3000 drops per metre tubing. Generation rates are up to 200 drops per second and merging rates are up to 10 drops per second. The impact of length scale, carrier fluid viscosity, and flow rates on system performance is considered theoretically and illustratively using 2D CFD simulations. Due to its flexibility, the widespread availability of components, and some favorable material properties compared to PDMS, this approach can be a useful part of a researcher's toolkit for prototyping droplet-based assays.

22 October 2008 in Journal of Micromechanics and Microengineering
Verified
Journal Article
Closed access
ABAmar Basu
Amar Basu
YGYogesh B Gianchandani
Yogesh B Gianchandani

11 April 2012 in Biomicrofluidics
Verified
Journal Article
Open access
PDF file
GKG. K. Kurup
G. K. Kurup
ABAmar Basu
Amar Basu
Particle concentration is a key unit operation in biochemical assays. Although there are many techniques for particle concentration in continuous-phase microfluidics, relatively few are available in multiphase (plug-based) microfluidics. Existing approaches generally require external electric or magnetic fields together with charged or magnetized particles. This paper reports a passive technique for particle concentration in water-in-oil plugs which relies on the interaction between particle sedimentation and the recirculating vortices inherent to plug flow in a cylindrical capillary. This interaction can be quantified using the Shields parameter (θ ), a dimensionless ratio of a particle’s drag force to its gravitational force, which scales with plug velocity. Three regimes of particle behavior are identified. When θ is less than the movement threshold (region I), particles sediment to the bottom of the plug where the internal vortices subsequently concentrate the particles at the rear of the plug. We demonstrate highly efficient concentration (∼100%) of 38 μm glass beads in 500 μm diameter plugs traveling at velocities up to 5 mm/s. As θ is increased beyond the movement threshold (region II), particles are suspended in well-defined circulation zones which begin at the rear of the plug. The length of the zone scales linearly with plug velocity, and at sufficiently large θ , it spans the length of the plug (region III). A second effect, attributed to the co-rotating vortices at the rear cap, causes particle aggregation in the cap, regardless of flow velocity. Region I is useful for concentrating/collecting particles, while the latter two are useful for mixing the beads with the solution. Therefore, the two key steps of a bead-based assay, concentration and resuspension, can be achieved simply by changing the plug velocity. By exploiting an interaction of sedimentation and recirculation unique to multiphase flow, this simple technique achieves particle concentration without on-chip components, and could therefore be applied to a range of heterogeneous screening assays in discrete nl plugs.

1 November 2013 in Journal of Molecular Biology
Verified
Journal Article
Open access
EDEric A. Davidson
Eric A. Davidson
ABAmar Basu
Amar Basu
TBTravis S. Bayer
Travis S. Bayer
Cells transmit and receive information via signalling pathways. A number of studies have revealed that information is encoded in the temporal dynamics of these pathways and has highlighted how pathway architecture can influence the propagation of signals in time and space. The functional properties of pathway architecture can also be exploited by synthetic biologists to enable precise control of cellular physiology. Here, we characterised the response of a bacterial light-responsive, two-component system to oscillating signals of varying frequencies. We found that the system acted as a low-pass filter, able to respond to low-frequency oscillations and unable to respond to high-frequency oscillations. We then demonstrate that the low-pass filtering behavior can be exploited to enable precise control of gene expression using a strategy termed pulse width modulation (PWM). PWM is a common strategy used in electronics for information encoding that converts a series of digital input signals to an analog response. We further show how the PWM strategy extends the utility of bacterial optogenetic control, allowing the fine-tuning of expression levels, programming of temporal dynamics, and control of microbial physiology via manipulation of a metabolic enzyme.