We report hertz level relative linewidth distributed feedback diode lasers with external optical feedback from a high finesse F-P cavity, and demonstrate the efficient phase noise suppression and laser linewidth reduction of the optical feedback technique. The laser phase noise is dramatically suppressed throughout the measurement frequency range. Especially at the Fourier frequency of 17 kHz, approximately the linewidth of the F-P reference cavity, the laser phase noise is significantly suppressed by more than 92 dB. Above this Fourier frequency, the noise maintains a white phase noise plateau as low as . The laser’s FWHM linewidth is reduced from 7 MHz to 4.4 Hz, and its instantaneous linewidth is 220 mHz in the Lorentzian fitting.
Carbohydrate antigen 199 (CA199) is a serum biomarker which has certain value and significance in the diagnosis, prognosis, treatment, and postoperative monitoring of cancer. In this study, a lateral flow immunoassay based on europium (III) polystyrene time-resolved fluorescence microspheres (TRFM-based LFIA), integrated with a portable fluorescence reader, has been successfully establish for rapid and quantitative analysis of CA199 in human serum. Briefly, time-resolved fluorescence microspheres (TRFMs) were conjugated with antibody I (Ab1) against CA199 as detection probes, and antibody II (Ab2) was coated as capture element, and a “TRFMs-Ab1-CA199-Ab2” sandwich format would form when CA199 was detected by the TRFM-based LFIA. Under the optimal parameters, the detection limit of the TRFM-based LFIA for visible quantitation with the help of an ultraviolet light was 4.125 U/mL, which was four times lower than that of LFIA based on gold nanoparticles. Additionally, the fluorescence ratio is well linearly correlated with the CA199 concentration (0.00–66.0 U/mL) and logarithmic concentration (66.0–264.0 U/mL) for quantitative detection. Serum samples from 10 healthy people and 10 liver cancer patients were tested to confirm the performances of the point-of-care application of the TRFM-based LFIA, 20.0 U/mL of CA199 in human serum was defined as the threshold for distinguishing healthy people from liver cancer patients with an accuracy of about 60%. The establishment of TRFM-based LFIA will provide a sensitive, convenient, and efficient technical support for rapid screening of CA199 in cancer diagnosis and prognosis.
We present a extended-cavity diode laser (ECDL) with kilohertz linewidth by optical feedback from a monolithic folded Fabry–Perot cavity (MFC). In our experiments, an MFC replaces the retroreflecting mirror in the traditional ECDL configuration. Beat-note measurements between this MFC-ECDL and a narrow-linewidth reference laser are performed and demonstrate that the linewidth of this MFC-ECDL is about . Phase locking of this MFC-ECDL to the reference laser is achieved with a unity gain as small as .
Many efforts have been taken in recent years to push atomic gravimeters toward practical applications. We demonstrate an atomic gravimeter named NIM-AGRb2 that is transportable and suitable for high-precision gravity measurements. Constraint-structured active vibration isolation (CS-AVI) is used to reduce the ground vibration noise. The constraint structure in CS-AVI ensures that the isolation platform only has vertical translation, with all other degrees of freedom (DoFs) being constrained. Therefore, the stability of active vibration isolation is enhanced. With the implementation of CS-AVI, the sensitivity of NIM-AGRb2 reached as low as 20.5 μGal/Hz1/2. The short-term sensitivity could be further reduced to 10.8 μGal/Hz1/2 in a seismologic observation station. Moreover, we evaluated the system noise of the gravimeter, and the results were consistent with our observations.
The paper describes a Raman-laser system with high performance for an absolute gravimeter that was based on 87Rb atom interferometer. As our gravimeter is a part of the standard acceleration of gravity of China, the Raman lasers’ characteristics should be considered. This laser system includes two diode lasers. The master laser is frequency locked through the frequency-modulation (FM) spectroscopy technology. Its maximum frequency drift is better than 50 kHz in 11 h, which is measured by home-made optical frequency comb. The slave laser is phase locked to the master laser with a frequency difference of 6.8346 GHz while using an optical phase lock loop (OPLL). The phase noise is lower than −105 dBc/Hz at the Fourier frequency from 200 Hz to 42 kHz. It is limited by the measurement sensitivity of the signal source analyzer in low Fourier frequency. Furthermore, the power fluctuation of Raman lasers’ pulses is also suppressed by a fast power servo system. While using this servo system, Raman lasers’ pulses could be fast re-locked while its fast turning on again in the pulse sequence. The peak value fluctuation of the laser power pulses is decreased from 25% to 0.7%, which is improved over 35 times. This Raman-laser system can stably operate over 500 h, which is suited for long-term highly precise and accurate gravity measurements.
Phase-modulator-generated Raman laser is widely used in atom gravimeters to simplify system and improve robustness. However, the induced additional sidebands (ASBs) lead to systematic errors in gravity measurement. This work presents a novel method to generate optical single-sideband (OSSB) Raman laser based on Faraday anomalous dispersion atomic filter (FADOF). The experimental result indicates that it can reduce the additional sidebands to lower than -50 dB, and the phase shift caused by ASBs is demonstrated to be effectively suppressed from 358.8 mrad to 2.2 mrad. Furthermore, this system has already applied on atom gravimeter to achieve primary gravity measurement. It shows that FADOF-based Raman laser is a new scheme for a compact atom absolute gravimeter.