Alan Wemyss

Dr. Alan Wemyss

International Institute for Nanocomposites Manufacturing, WMG, University of Warwick, Coventry CV4 7AL, UK
orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 May 2020 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
YZYuxin Zhang
Yuxin Zhang
ZZZhen Zhang
Zhen Zhang
Alan WemyssAlan Wemyss
Alan Wemyss
Chaoying WanChaoying Wan
Chaoying Wan
YLYongtao Liu
Yongtao Liu
SWShifeng Wang
Shifeng Wang

2 July 2021 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
PSParesh Kumar Samantaray
Paresh Kumar Samantaray
ALAlastair Little
Alastair Little
Alan WemyssAlan Wemyss
Alan Wemyss
EIEleni Iacovidou
Eleni Iacovidou
Chaoying WanChaoying Wan
Chaoying Wan

7 January 2021 in Angewandte Chemie International Edition
Verified
Journal Article
Open access
PDF file
Alan WemyssAlan Wemyss
Alan Wemyss
CEChristopher Ellingford
Christopher Ellingford
YMYoshihiro Morishita
Yoshihiro Morishita
Chris BowenChris Bowen
Chris Bowen
Chaoying WanChaoying Wan
Chaoying Wan
While the fascinating field of soft machines has grown rapidly over the last two decades, the materials they are constructed from have remained largely unchanged during this time. Parallel activities have led to significant advances in the field of dynamic polymer networks, leading to the design of three‐dimensionally cross‐linked polymeric materials that are able to adapt and transform through stimuli‐induced bond exchange. Recent work has begun to merge these two fields of research by incorporating the stimuli‐responsive properties of dynamic polymer networks into soft machine components. These include dielectric elastomers, stretchable electrodes, nanogenerators, and energy storage devices. In this Minireview, we outline recent progress made in this emerging research area and discuss future directions for the field.

16 January 2020 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
CEChristopher Ellingford
Christopher Ellingford
RZRunan Zhang
Runan Zhang
Alan WemyssAlan Wemyss
Alan Wemyss
YZYan Zhang
Yan Zhang
OBOliver B. Brown
Oliver B. Brown
Chaoying WanChaoying Wan
Chaoying Wan

15 October 2018 in ACS Applied Materials & Interfaces
Verified
Journal Article
Closed access
CEChristopher Ellingford
Christopher Ellingford
RZRunan Zhang
Runan Zhang
Alan WemyssAlan Wemyss
Alan Wemyss
Chris BowenChris Bowen
Chris Bowen
Tony McNallyTony McNally
Tony McNally
Chaoying WanChaoying Wan
Chaoying Wan

26 July 2021 in Polymers
Verified
Journal Article
Open access
PDF file
ALAlastair Little
Alastair Little
Alan WemyssAlan Wemyss
Alan Wemyss
DHDavid M. Haddleton
David M. Haddleton
BTBowen Tan
Bowen Tan
ZSZhaoyang Sun
Zhaoyang Sun
Chaoying WanChaoying Wan
Chaoying Wan
The rise in demand for biodegradable plastic packaging with high barrier properties has spurred interest in poly(lactic acid-co-glycolic acid) (PLGA) copolymers with a relatively high glycolide content. In this work, we examined how reaction conditions affect the synthesis of PLGA25 (L:G 25:75) through the ring-opening polymerisation of d-l-lactide (L) and glycolide (G), using tin 2-ethylhexanoate (Sn(Oct)2) as the catalyst and 1-dodecanol as the initiator. The effects of varying the initiator concentration, catalyst concentration, reaction time, and temperature on the molecular weight, monomer conversion, and thermal properties of PLGA25 were investigated. Increasing the reaction temperature from 130 to 205 °C significantly reduced the time required for high monomer conversions but caused greater polymer discolouration. Whilst increasing the [M]:[C] from 6500:1 to 50,000:1 reduced polymer discolouration, it also resulted in longer reaction times and higher reaction temperatures being required to achieve high conversions. High Mn and Mw values of 136,000 and 399,000 g mol−1 were achieved when polymerisations were performed in the solid state at 150 °C using low initiator concentrations. These copolymers were analysed using high temperature SEC at 80 °C, employing DMSO instead of HFIP as the eluent.