Seok Hyun Kim

Seok Hyun Kim


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 February 2015 in Energies
Verified
Journal Article
Open access
PDF file
SKSeok Hyun Kim
Seok Hyun Kim
KSKyungju Shin
Kyungju Shin
BCBo-Eun Choi
Bo-Eun Choi
JJJae Hun Jo
Jae Hun Jo
SCSoo Cho
Soo Cho
Young-Hum ChoYoung-Hum Cho
Young-Hum Cho
The construction industry has made considerable energy-saving efforts in buildings, and studies of energy-savings are ongoing. Shading is used to control the solar radiation transferred through windows. Many studies have examined the position and type of shading in different countries, but few have investigated the effects of shading installation in Korea. In this study, the case of the shading installation according to the standard of Korea, and variations of the heating and cooling load in the unit area on the performance of the windows were examined. This study compared the variations of the heating and cooling load in the case of horizontal shading and the changing position of venetian blinds. This study confirmed that horizontal shading longer than the standard length in Korea saved a maximum of 13% energy consumption. This study confirmed the point of change of energy consumption by the Solar Heat Gain Coefficient (SHGC) variations. The exterior venetian blinds and those between glazing were unaffected by the SHGC. On the other hand, in the case of a south façade, the interior venetian blinds resulted in 24% higher energy consumption than the installation of horizontal shading in case of Window to Wall Ratio (WWR): 80%, U-value: 2.1 and SHGC: 0.4.

2 June 2017 in Sustainability
Verified
Journal Article
Open access
PDF file
SCSoo Cho
Soo Cho
SKSeok Hyun Kim
Seok Hyun Kim
Window performance in buildings is very important for energy saving. Many efforts have been made towards saving energy in buildings, and research has focused attention on enhancing the thermal performance of windows. Vacuum glazing has attracted much interest as a means of enhancing the thermal performance of windows by strengthening insulation performance. However, the performance of vacuum glazing differs based on various component combinations, therefore, further study on vacuum glazing is needed. In this paper, through simulations, the authors confirmed the heat transfer value (U-value) of the vacuum glazing composed of various combinations (glass type, number of layers, interval of pillar, etc.). A physical test of vacuum glazing was also performed using standard test methods of windows and the U-value of the vacuum glazing by various intervals of the pillar position was confirmed. The simulation revealed a U-value for vacuum glazing of 0.682–1.466 W/m2·K as per the interval of the pillar position, the performance of solar heat gain, and visible light transmission. The U-value of the double vacuum glazing was calculated as 0.607–1.154 W/m2·K and was similar regardless of the interval of pillar position, the performance of solar heat gain, and visible light transmission. Based on the results of the energy simulation, in the case of a used low U-value of vacuum glazing, the heating and cooling energy consumption in buildings decreased by 2.46%, than when low-e glass and argon gas filled layers were used in windows. Furthermore, in double vacuum glazing, the heating and cooling energy consumption in buildings decreased by 3.91%.

7 November 2019 in Sustainability
Verified
Journal Article
Open access
PDF file
SUSung Ukjoo
Sung Ukjoo
SKSeok Hyun Kim
Seok Hyun Kim
A double-skin facade makes it possible to gain irradiance through the glass on the outer side in summer, and to increase the temperature of air flowing in the cavity so as to induce the flow of air current. Therefore, a double-skin facade is able to reduce the load of the outer skin, which is delivered from the outside to the inside in summer, and to serve as a buffer space for the internal and external environments in winter, and thereby prevent heat loss from the building envelope. Theoretical analysis was conducted to review the heat effects of a double-skin facade and to evaluate the performance of a plan for indoor load reduction. This study carried out a field measurement of a building with a double-skin facade and then analyzed the thermal phenomenon occurring in between the outer skin of the outside and the skin of the inside facing the building surface, according to the effects of irradiance going into the double-skin facade cavity. In order to propose an indoor air conditioning energy reduction plan using preheated air through the double-skin facade, this study utilized a building simulation to be implemented on the target building and then analyzed the effects of the improvement plan for the double-skin facade. A simulation model was suggested that implemented the aforementioned airflow network and analyzed the ventilation performance and energy performance according to the application of alternative plans and thermal effect. To find the actual state of operation of the double-skin facade in winter, this study measured the target building. A solar chimney-based double-skin facade was analyzed in winter. As a result, with the application of a solar chimney and a rise in its height, the available capacity of relatively larger solar heat increased, and therefore the proposed plan had excellent performance in terms of heating energy saving. When the thermal effect was applied to the solar chimney, the heating energy use effect of the solar irradiance of the double-skin facade was larger. When thermal effect was applied to a three-floor solar chimney, the heating energy use increased to about 7.6 times higher than that of the original performance of the double-skin facade.

10 October 2019 in Energies
Verified
Journal Article
Open access
PDF file
SKSeok Hyun Kim
Seok Hyun Kim
Hakgeun JeongHakgeun Jeong
Hakgeun Jeong
SCSoo Cho
Soo Cho
The interest in zero energy buildings is increasing in South Korea. Zero energy buildings need to save energy by using passive technology. The window performance is important to the thermal insulation of the building. Also, the government regulates the window performance through regulation and standards. However, it is difficult to predict window performance because the components of the window have become complicated due to the various materials used in the glass and frame. Based on window performance standards and regulations, the quality of window performance was managed. In this research, to consider thermal performance in proper window design in South Korea, we confirmed the impact on the thermal performance of the window through various kinds of materials and shapes. The authors also propose a window shape classification and frame calculation method based on actual test results. The authors analyzed the thermal performance data of the windows provided by the Korea Energy Agency and confirmed the change in the thermal performance of the windows by year and by frame material. The average U-value of the window decreased from 2012 to 2015 and maintained similar values until 2017. In 2018, this value was decreased to comply. Also, the authors confirmed the U-value of the windows through actual physical experiments and confirmed the change in thermal performance by the construction of the windows based on the results. The results show, in the case of aluminum windows, the U-value corresponding to Grade 3 (1.4–2.1 W/m2·K) was as high as about 60%. Regarding the analyzed results of the U-values of PVC windows, Grade 3 (U-value of 1.4–2.1 W/m2·K) accounted for about 35%, and Grade 2 (U-value of 1.0–1.4 W/m2·K) for about 29%. This paper also confirmed that the frame U-value of the PVC windows is lower than the frame U-value of the aluminum windows. Therefore, the authors proposed the performance index of the glazing part in PVC and aluminum window design. The results of this research can be used as basic data to identify problems in the method of determining the performance of windows in Korea.

5 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
SUSung Ukjoo
Sung Ukjoo
SKSeok Hyun Kim
Seok Hyun Kim
There is much research on zero energy buildings. In this paper, technologies and policies to improve the building energy efficiency of zero energy buildings are presented. The zero energy building certification system in Korea is introduced, and the evaluation is carried out based on the energy self-reliance rate that enables zero energy buildings. Zero energy buildings are able to minimize energy consumption due to the application of highly efficient building materials and equipment technology. In this research, to increase the prevalence of zero energy buildings in Korea, the authors propose a zero energy building technology package. Using a passive and active technology package, we confirmed the necessity and detailed requirements of each technology parameter. We analyze and classify Korean building material testing methods and performance standards, and propose passive and active technology packages, modules, material performance testing methods and minimum requirement performance standards. Finally, this study proposed a table presenting the test methods, standard and minimum value of performance. By these results, the authors confirmed the effectiveness and availability of passive and active technical packages.