W. Matthew Leevy

W. Matthew Leevy


Research Focus & Metrics

Academic Career Length

23Years (2004-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2017 in Sensors
Verified
Journal Article
Open access
PDF file
JCJustin Ceh
Justin Ceh
TYTom Youd
Tom Youd
ZMZach Mastrovich
Zach Mastrovich
CPCody Peterson
Cody Peterson
SKSarah Khan
Sarah Khan
WLW. Matthew Leevy
W. Matthew Leevy
Radiopacity is a critical property of materials that are used for a range of radiological applications, including the development of phantom devices that emulate the radiodensity of native tissues and the production of protective equipment for personnel handling radioactive materials. Three-dimensional (3D) printing is a fabrication platform that is well suited to creating complex anatomical replicas or custom labware to accomplish these radiological purposes. We created and tested multiple ABS (Acrylonitrile butadiene styrene) filaments infused with varied concentrations of bismuth (1.2–2.7 g/cm3), a radiopaque metal that is compatible with plastic infusion, to address the poor gamma radiation attenuation of many mainstream 3D printing materials. X-ray computed tomography (CT) experiments of these filaments indicated that a density of 1.2 g/cm3 of bismuth-infused ABS emulates bone radiopacity during X-ray CT imaging on preclinical and clinical scanners. ABS-bismuth filaments along with ABS were 3D printed to create an embedded human nasocranial anatomical phantom that mimicked radiological properties of native bone and soft tissue. Increasing the bismuth content in the filaments to 2.7 g/cm3 created a stable material that could attenuate 50% of 99mTechnetium gamma emission when printed with a 2.0 mm wall thickness. A shielded test tube rack was printed to attenuate source radiation as a protective measure for lab personnel. We demonstrated the utility of novel filaments to serve multiple radiological purposes, including the creation of anthropomorphic phantoms and safety labware, by tuning the level of radiation attenuation through material customization.

16 February 2011 in Molecular Pharmaceutics
Verified
Journal Article
Closed access
BSBryan A. Smith
Bryan A. Smith
SGSeth Gammon
Seth Gammon
SXShuzhang Xiao
Shuzhang Xiao
WWWei Wang
Wei Wang
SCSarah Chapman
Sarah Chapman
WLW. Matthew Leevy
W. Matthew Leevy

8 October 2014 in Sensors
Verified
Journal Article
Open access
PDF file
MMMatthew N. Metzinger
Matthew N. Metzinger
BMBernadette Miramontes
Bernadette Miramontes
PZPeng Zhou
Peng Zhou
YLYueying Liu
Yueying Liu
SCSarah Chapman
Sarah Chapman
WLW. Matthew Leevy
W. Matthew Leevy
Numerous obesity studies have coupled murine models with non-invasive methods to quantify body composition in longitudinal experiments, including X-ray computed tomography (CT) or quantitative nuclear magnetic resonance (QMR). Both microCT and QMR have been separately validated with invasive techniques of adipose tissue quantification, like post-mortem fat extraction and measurement. Here we report a head-to-head study of both protocols using oil phantoms and mouse populations to determine the parameters that best align CT data with that from QMR. First, an in vitro analysis of oil/water mixtures was used to calibrate and assess the overall accuracy of microCT vs. QMR data. Next, experiments were conducted with two cohorts of living mice (either homogenous or heterogeneous by sex, age and genetic backgrounds) to assess the microCT imaging technique for adipose tissue segmentation and quantification relative to QMR. Adipose mass values were obtained from microCT data with three different resolutions, after which the data were analyzed with different filter and segmentation settings. Strong linearity was noted between the adipose mass values obtained with microCT and QMR, with optimal parameters and scan conditions reported herein. Lean tissue (muscle, internal organs) was also segmented and quantified using the microCT method relative to the analogous QMR values. Overall, the rigorous calibration and validation of the microCT method for murine body composition, relative to QMR, ensures its validity for segmentation, quantification and visualization of both adipose and lean tissues.

4 April 2012 in Journal of Visualized Experiments
Verified
Journal Article
Open access
PDF file
TSTodd A. Sasser
Todd A. Sasser
SCSarah E. Chapman
Sarah E. Chapman
SLShengting Li
Shengting Li
CHCaroline Hudson
Caroline Hudson
SOSean P. Orton
Sean P. Orton
WLW. Matthew Leevy
W. Matthew Leevy
Fat content analysis is routinely conducted in studies utilizing murine obesity models. Emerging methods in small animal CT imaging...

6 December 2004 in New Journal of Chemistry
Verified
Journal Article
Closed access
PDF file
WLW. Matthew Leevy
W. Matthew Leevy
MGMichael R. Gokel
Michael R. Gokel
GHGeorge B. Hughes-Strange
George B. Hughes-Strange
PSPaul H. Schlesinger
Paul H. Schlesinger
George GokelGeorge Gokel
George Gokel
Synthetic hydraphile channels were systematically varied at the side arm position and tested under neutral and acidic conditions against the Gram-negative bacterium E. coli. Side arm structure is a critical determinant of channel activity within the bilayer and greatly influences toxicity. The biological activity data correlate remarkably well with the results of Na+ transport studies conducted using synthetic liposome systems. Experiments to determine minimum inhibitory concentrations (MIC) were conducted under both neutral and acidic conditions. Hydraphile toxicity was diminished at pH = 5.5, compared to that at pH = ∼7, providing an example of a pH-dependent, synthetic, non-peptide ion channel.

28 December 2014 in Journal of Visualized Experiments
Verified
Journal Article
Open access
PDF file
RBRashna D. Balsara
Rashna D. Balsara
SCSarah E. Chapman
Sarah E. Chapman
ISIan M. Sander
Ian M. Sander
DDDeborah L. Donahue
Deborah L. Donahue
LLLucas Liepert
Lucas Liepert
WLW. Matthew Leevy
W. Matthew Leevy
Stroke is the third leading cause of death among Americans 65 years of age or older1. The quality of life for patients who suffer from a stroke fails to return to normal in a large majority of patients2, which is mainly due to current lack of clinical treatment for acute stroke. This necessitates understanding the physiological effects of cerebral ischemia on brain tissue over time and is a major area of active research. Towards this end, experimental progress has been made using rats as a preclinical model for stroke, particularly, using non-invasive methods such as 18F-fluorodeoxyglucose (FDG) coupled with Positron Emission Tomography (PET) imaging3,10,17. Here we present a strategy for inducing cerebral ischemia in rats by middle cerebral artery occlusion (MCAO) that mimics focal cerebral ischemia in humans, and imaging its effects over 24 hr using FDG-PET coupled with X-ray computed tomography (CT) with an Albira PET-CT instrument. A VOI template atlas was subsequently fused to the cerebral rat data to enable a unbiased analysis of the brain and its sub-regions4. In addition, a method for 3D visualization of the FDG-PET-CT time course is presented. In summary, we present a detailed protocol for initiating, quantifying, and visualizing an induced ischemic stroke event in a living Sprague-Dawley rat in three dimensions using FDG-PET.