The recent trend in electrocardiogram (ECG) device development is towards wireless body sensors applied for patient monitoring. The ultimate goal is to develop a multi-functional body sensor that will provide synchronized vital bio-signs of the monitored user. In this paper, we present an ECG sensor for long-term monitoring, which measures the surface potential difference between proximal electrodes near the heart, called differential ECG lead or differential lead, in short. The sensor has been certified as a class IIa medical device and is available on the market under the trademark Savvy ECG. An improvement from the user’s perspective—immediate access to the measured data—is also implemented into the design. With appropriate placement of the device on the chest, a very clear distinction of all electrocardiographic waves can be achieved, allowing for ECG recording of high quality, sufficient for medical analysis. Experimental results that elucidate the measurements from a differential lead regarding sensors’ position, the impact of artifacts, and potential diagnostic value, are shown. We demonstrate the sensors’ potential by presenting results from its various areas of application: medicine, sports, veterinary, and some new fields of investigation, like hearth rate variability biofeedback assessment and biometric authentication.
In this paper, we present AMS-DEMO, an asynchronous master-slave implementation of DEMO, an evolutionary algorithm for multi-objective optimization. AMS-DEMO was designed for solving time-intensive problems efficiently on both homogeneous and heterogeneous parallel computer architectures. The algorithm is used as a test case for the asynchronous master-slave parallelization of multi-objective optimization that has not yet been thoroughly investigated. Selection lag is identified as the key property of the parallelization method, which explains how its behavior depends on the type of computer architecture and the number of processors. It is arrived at analytically and from the empirical results. AMS-DEMO is tested on a benchmark problem and a time-intensive industrial optimization problem, on homogeneous and heterogeneous parallel setups, providing performance results for the algorithm and an insight into the parallelization method. A comparison is also performed between AMS-DEMO and generational master-slave DEMO to demonstrate how the asynchronous parallelization method enhances the algorithm and what benefits it brings compared to the synchronous method.
Fretting is a phenomenon that occurs at the contacts of surfaces that are subjected to oscillatory relative movement of small amplitudes. Depending on service conditions, fretting may significantly reduce the service life of a component due to fretting fatigue. In this regard, the analysis of stresses at contact is of great importance for predicting the lifetime of components. However, due to the complexity of the fretting phenomenon, analytical solutions are available for very selective situations and finite element (FE) analysis has become an attractive tool to evaluate stresses and to study fretting problems. Recent laboratory studies in fretting fatigue suggested the presence of stress singularities in the stick-slip zone. In this paper, we constructed finite element models, with different element sizes, in order to verify the existence of stress singularity under fretting conditions. Based on our results, we did not find any singularity for the considered loading conditions and coefficients of friction. Since no singularity was found, the present paper also provides some comments regarding the convergence rate. Our analyses showed that the convergence rate in stress components depends on coefficient of friction, implying that this rate also depends on the loading condition. It was also observed that errors can be relatively high for cases with a high coefficient of friction, suggesting the importance of mesh refinement in these situations. Although the accuracy of the FE analysis is very important for satisfactory predictions, most of the studies in the literature rarely provide information regarding the level of error in simulations. Thus, some recommendations of mesh sizes for those who wish to perform FE analysis of fretting problems are provided for different levels of accuracy.
20 June 2012 in Journal of Computational Chemistry
Objective: Several hypotheses for the origin of the U wave in electrocardiograms have been proposed. We have set out to explore and test alternative modes for U‐wave genesis via computer simulations. Methods and Results: A spatial model of a left ventricle has been constructed from 12 layers composed of cubic cells. Each cell is assigned its own time‐dependent action potential with its own contribution to the electrical potential at arbitrary points where ECGs are measured. Simulated ECGs show that U waves can be generated using various combinations of action potentials (APs) across the different layers of the ventricular wall. We demonstrate a new mode of U‐wave genesis, even with small differences in the repolarization. Conclusion: The U wave can be generated in the presence of strong intercellular coupling. Myocardial layers with prolonged action potentials, like M cells, are not necessarily needed for U‐wave genesis.
30 January 2016 in Scalable Computing: Practice and Experience