Generation and transmission of voltage signals in a kinetic inductance detector made of a superconducting nanowire stripline is investigated on the basis of superconducting electromagnetism. We show that electric signals traveling along the stripline in this detector can be regarded as a Swihart mode. An equation which can describe the generation and transmission of voltage pulses in this detector is derived. A pair of voltage pulses with opposite polarities are created when a spatiotemporal variation in the density of the superconducting condensate occurs in a small region of this superconducting nanowire. The voltage pulses propagate along the stripline in the directions opposite to each other with the Swihart velocity. The characteristic of the radiation detector named current-biased kinetic inductance detector (CB-KID) is well described by our model.
9 September 2021 in IEEE Transactions on Applied Superconductivity
Neutron imaging is one of the most powerful tools for nondestructive inspection owing to the unique characteristics of neutron beams, such as high permeability for many heavy metals, high sensitivity for certain light elements, and isotope selectivity owing to a specific nuclear reaction between an isotope and neutrons. In this study, we employed a superconducting detector, current-biased kinetic-inductance detector (CB-KID) for neutron imaging using a pulsed neutron source. We employed the delay-line method, and high spatial resolution imaging with only four reading channels was achieved. We also performed wavelength-resolved neutron imaging by the time-of-flight method for the pulsed neutron source. We obtained the neutron transmission images of a Gd–Al alloy sample, inside which single crystals of GdAl $_3$ were grown, using the delay-line CB-KID. Single crystals were well imaged, in both shapes and distributions, throughout the Al–Gd alloy. We identified Gd nuclei via neutron transmissions that exhibited characteristic suppression above the neutron wavelength of 0.03 nm. In addition, the $^{155}$ Gd resonance dip, a dip structure of the transmission caused by the nuclear reaction between an isotope and neutrons, was observed even when the number of events was summed over a limited area of 15 $\mu$ m × 12 $\mu$ m. Gd selective imaging was performed using the resonance dip of $^{155}$ Gd, and it showed clear Gd distribution even with a limited neutron wavelength range of 1 pm.
1 September 2019 in Journal of Physics: Conference Series
Transmission of voltage pulses generated by local heating in a kinetic inductance detector made of a superconducting stripline is theoretically investigated on the basis of the TDGL equation. The effect of thermal diffusion is also incorporated into the electrodynamics of this system. We derive an equation that can describe the generation and transmission of voltage pulses in this detector. A pair of voltage pulses with opposite polarities are created when a spatiotemporal variation in the superconducting order parameter occurs in a small region of this superconducting stripline. We clarify the characteristic feature in the shape of the voltage pulse.
14 July 2023 in Journal of Applied Crystallography