Kinda Khalaf

Prof. Kinda Khalaf


Research Focus & Metrics

Academic Career Length

30Years (1997-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 December 2022 in Frontiers in Medical Technology
Verified
Journal Article
Open access
AHAbdul Aziz Hulleck
Abdul Aziz Hulleck
DMDhanya Menoth Mohan
Dhanya Menoth Mohan
NANada Abdallah
Nada Abdallah
MRMarwan El Rich
Marwan El Rich
KKKinda Khalaf
Kinda Khalaf
Background: Despite being available for more than three decades, quantitative gait analysis remains largely associated with research institutions and not well leveraged in clinical settings. This is mostly due to the high cost/cumbersome equipment and complex protocols and data management/analysis associated with traditional gait labs, as well as the diverse training/experience and preference of clinical teams. Observational gait and qualitative scales continue to be predominantly used in clinics despite evidence of less efficacy of quantifying gait.Research objective: This study provides a scoping review of the status of clinical gait assessment, including shedding light on common gait pathologies, clinical parameters, indices, and scales. We also highlight novel state-of-the-art gait characterization and analysis approaches and the integration of commercially available wearable tools and technology and AI-driven computational platforms.Methods: A comprehensive literature search was conducted within PubMed, Web of Science, Medline, and ScienceDirect for all articles published until December 2021 using a set of keywords, including normal and pathological gait, gait parameters, gait assessment, gait analysis, wearable systems, inertial measurement units, accelerometer, gyroscope, magnetometer, insole sensors, electromyography sensors. Original articles that met the selection criteria were included.Results and significance: Clinical gait analysis remains highly observational and is hence subjective and largely influenced by the observer's background and experience. Quantitative Instrumented gait analysis (IGA) has the capability of providing clinicians with accurate and reliable gait data for diagnosis and monitoring but is limited in clinical applicability mainly due to logistics. Rapidly emerging smart wearable technology, multi-modality, and sensor fusion approaches, as well as AI-driven computational platforms are increasingly commanding greater attention in gait assessment. These tools promise a paradigm shift in the quantification of gait in the clinic and beyond. On the other hand, standardization of clinical protocols and ensuring their feasibility to map the complex features of human gait and represent them meaningfully remain critical challenges.

8 June 2021 in Frontiers in Neurology
Verified
Journal Article
Open access
DMDhanya Menoth Mohan
Dhanya Menoth Mohan
AKAhsan Habib Khandoker
Ahsan Habib Khandoker
SWSabahat Asim Wasti
Sabahat Asim Wasti
SASarah Ismail Ibrahim Ismail Alali
Sarah Ismail Ibrahim Ismail Alali
HJHerbert F. Jelinek
Herbert F. Jelinek
KKKinda Khalaf
Kinda Khalaf
Background: Gait dysfunction or impairment is considered one of the most common and devastating physiological consequences of stroke, and achieving optimal gait is a key goal for stroke victims with gait disability along with their clinical teams. Many researchers have explored post stroke gait, including assessment tools and techniques, key gait parameters and significance on functional recovery, as well as data mining, modeling and analyses methods.Research Question: This study aimed to review and summarize research efforts applicable to quantification and analyses of post-stroke gait with focus on recent technology-driven gait characterization and analysis approaches, including the integration of smart low cost wearables and Artificial Intelligence (AI), as well as feasibility and potential value in clinical settings.Methods: A comprehensive literature search was conducted within Google Scholar, PubMed, and ScienceDirect using a set of keywords, including lower extremity, walking, post-stroke, and kinematics. Original articles that met the selection criteria were included.Results and Significance: This scoping review aimed to shed light on tools and technologies employed in post stroke gait assessment toward bridging the existing gap between the research and clinical communities. Conventional qualitative gait analysis, typically used in clinics is mainly based on observational gait and is hence subjective and largely impacted by the observer's experience. Quantitative gait analysis, however, provides measured parameters, with good accuracy and repeatability for the diagnosis and comparative assessment throughout rehabilitation. Rapidly emerging smart wearable technology and AI, including Machine Learning, Support Vector Machine, and Neural Network approaches, are increasingly commanding greater attention in gait research. Although their use in clinical settings are not yet well leveraged, these tools promise a paradigm shift in stroke gait quantification, as they provide means for acquiring, storing and analyzing multifactorial complex gait data, while capturing its non-linear dynamic variability and offering the invaluable benefits of predictive analytics.

8 August 2017 in BMJ Open Diabetes Research & Care
Verified
Journal Article
Open access
PDF file
HJHerbert Jelinek
Herbert Jelinek
WOWael M Osman
Wael M Osman
AKAhsan Khandoker
Ahsan Khandoker
KKKinda Khalaf
Kinda Khalaf
SLSungmun Lee
Sungmun Lee
HAHabiba Alsafar
Habiba Alsafar
Objective To assess clinical profiles of patients with type 2 diabetes in the United Arab Emirates (UAE), including patterns, frequencies, and risk factors of microvascular and macrovascular complications. Research design and methods Four hundred and ninety patients with type 2 diabetes were enrolled from two major hospitals in Abu Dhabi. The presence of microvascular and macrovascular complications was assessed using logistic regression, and demographic, clinical and laboratory data were collected. Significance was set at p<0.05. Results Hypertension (83.40%), obesity (90.49%) and dyslipidemia (93.43%) were common type 2 diabetes comorbidities. Most of the patients had relatively poor glycemic control and presented with multiple complications (83.47% of patients had one or more complication), with frequent renal involvement. The most frequent complication was retinopathy (13.26%). However, the pattern of complications varied based on age, where in patients 65 years old. Low estimated glomerular filtration rate in combination with disease duration was the most significant risk factor in the development of a diabetic-associated complication especially for coronary artery disease, whereas age, lipid values and waist circumference were significantly associated with the development of diabetic retinopathy. Conclusions Patients with type 2 diabetes mellitus in the UAE frequently present with comorbidities and complications. Renal disease was found to be the most common comorbidity, while retinopathy was noted as the most common diabetic complication. This emphasizes the need for screening and prevention program toward early, asymptomatic identification of comorbidities and commence treatment, especially for longer disease duration.

1 June 2015 in Clinical Biochemistry
Verified
Journal Article
Open access
LML. Maschirow
L. Maschirow
KKKinda Khalaf
Kinda Khalaf
Hayder Al-AubaidyHayder Al-Aubaidy
Hayder Al-Aubaidy
HJHerbert Jelinek
Herbert Jelinek
This study aims to increase understanding of the connection between oxidative stress and inflammation in diabetes disease progression to provide a basis for investigating improved diagnostic possibilities, treatment and prevention of prediabetes. Differences in the level of biochemical markers of oxidative stress (erythrocyte GSH/GSSG and urinary 8-isoprostane), inflammation (CRP, IL-6), endothelial dysfunction (plasma homocysteine, urinary 8-hydroxy-2-deoxy-guanosine) and coagulation/fibrinolysis (C5a, D-Dimer) were determined in prediabetes and control subjects. While no difference was found in the 8-isoprostane levels between the two groups, the erythrocyte GSH/GSSG ratio was significantly reduced in the prediabetes group compared to control, indicating increased oxidative stress in the prediabetic state. Both urinary 8-OHdG and surprisingly also plasma homocysteine were significantly elevated in the prediabetes group, indicating endothelial dysfunction. The inflammation markers were slightly elevated in the prediabetic subjects and the same trend was found for the coagulation/fibrinolysis markers C5a and D-Dimer. These results were however not significant. The small elevation of blood glucose levels in the prediabetic state may have a detectable influence on endothelial function as indicated by changes to 8-OHdG, indicating an increased DNA-damage and homocysteine release from endothelial cells. Increased oxidative stress as indicated by the reduced GSH/GSSG ratio is likely to be the link between the moderate hyperglycaemia in prediabetes and pathological changes in endothelial function, which in the long-term may promote atherogenesis and result in the development of cardiovascular disease. Early detection of prediabetes is essential to avoid diabetes development and the associated complications like cardiovascular disease. The GSH/GSSG ratio and biomarkers like urinary 8-OHdG and plasma homocysteine offer a possible tool for the assessment of prediabetes in prevention screenings.

1 August 2015 in Clinical Biomechanics
Verified
Journal Article
Closed access
MAMorteza Asgari
Morteza Asgari
MSMohammad Ali Sanjari
Mohammad Ali Sanjari
HMHamid Reza Mokhtarinia
Hamid Reza Mokhtarinia
SSSamaneh Moeini Sedeh
Samaneh Moeini Sedeh
KKKinda Khalaf
Kinda Khalaf
MPMohamad Parnianpour
Mohamad Parnianpour

26 June 2020 in Sensors
Verified
Journal Article
Open access
PDF file
MAMasoud Abdollahi
Masoud Abdollahi
SASajad Ashouri
Sajad Ashouri
MAMohsen Abedi
Mohsen Abedi
NANasibeh Azadeh-Fard
Nasibeh Azadeh-Fard
MPMohamad Parnianpour
Mohamad Parnianpour
EREhsan Rashedi
Ehsan Rashedi
Nonspecific low back pain (NSLBP) constitutes a critical health challenge that impacts millions of people worldwide with devastating health and socioeconomic consequences. In today’s clinical settings, practitioners continue to follow conventional guidelines to categorize NSLBP patients based on subjective approaches, such as the STarT Back Screening Tool (SBST). This study aimed to develop a sensor-based machine learning model to classify NSLBP patients into different subgroups according to quantitative kinematic data, i.e., trunk motion and balance-related measures, in conjunction with STarT output. Specifically, inertial measurement units (IMU) were attached to the trunks of ninety-four patients while they performed repetitive trunk flexion/extension movements on a balance board at self-selected pace. Machine learning algorithms (support vector machine (SVM) and multi-layer perceptron (MLP)) were implemented for model development, and SBST results were used as ground truth. The results demonstrated that kinematic data could successfully be used to categorize patients into two main groups: high vs. low-medium risk. Accuracy levels of ~75% and 60% were achieved for SVM and MLP, respectively. Additionally, among a range of variables detailed herein, time-scaled IMU signals yielded the highest accuracy levels (i.e., ~75%). Our findings support the improvement and use of wearable systems in developing diagnostic and prognostic tools for various healthcare applications. This can facilitate development of an improved, cost-effective quantitative NSLBP assessment tool in clinical and home settings towards effective personalized rehabilitation.