Shyy Woei Chang

Dr. Shyy Woei Chang


Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2008 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
SCShyy Woei Chang
Shyy Woei Chang
TLTong-Minn Liou
Tong-Minn Liou
SCShyr Fuu Chiou
Shyr Fuu Chiou
SCShuen Fei Chang
Shuen Fei Chang

21 January 2010 in Journal of Turbomachinery
Verified
Journal Article
Closed access
PDF file
SCShyy Woei Chang
Shyy Woei Chang
TLTong-Miin Liou
Tong-Miin Liou
TYTsun Lirng Yang
Tsun Lirng Yang
GHGuo Fang Hong
Guo Fang Hong

2 May 2006 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
SCShyy Woei Chang
Shyy Woei Chang
TLTong-Minn Liou
Tong-Minn Liou
JHJui-Hung Hung
Jui-Hung Hung
WYWen-Hsien Yeh
Wen-Hsien Yeh

30 June 2005 in International Journal of Heat and Mass Transfer
Verified
Journal Article
Closed access
SCShyy Woei Chang
Shyy Woei Chang
TLTong-Miin Liou
Tong-Miin Liou
WJWei-Chen Juan
Wei-Chen Juan

10 January 2017 in Journal of Heat Transfer
Verified
Journal Article
Closed access
PDF file
TLT. M. Liou
T. M. Liou
SCShyy Woei Chang
Shyy Woei Chang
YLY. A. Lan
Y. A. Lan
SCS. P. Chan
S. P. Chan
YLY. S. Liu
Y. S. Liu

1 December 2006 in Heat Transfer Engineering
Verified
Journal Article
Closed access
SCShyy Woei Chang
Shyy Woei Chang
TYTsun Lirng Yang
Tsun Lirng Yang
WWWei Jen Wang
Wei Jen Wang
An experimental study of heat transfer in a radially rotating twin-pass trapezoidal-sectioned duct with two opposite walls roughened by 45° staggered ribs was performed. Two channel orientations of 0° and 45° from the direction of rotation were tested. At each Reynolds number of 5000, 7500, 10000, 12500, and 15000, local Nusselt numbers along the centerlines of two rib-roughened surfaces with five different heating levels were acquired at rotating numbers of 0, 0.1, 0.3, 0.5, 0.7, and 1. A selection of experimental results illustrates the isolated and interactive influences of convective inertial, Coriolis, and rotating buoyancy forces on local and centerline-averaged heat transfers. The isolated Coriolis force-effect improves heat transfer over two unstable surfaces of the rotating twin-pass channel. The rotating buoyancy effect undermines local heat transfer, but its influence is alleviated when the rotating number increases. At rotating number of 0.7 and 1, the rotating buoyancy force acting with counter-flow manner considerably impairs local heat transfer in the end-region of the first passage with radially outward flow. With the rotating numbers in the range of 0.1 to 1, the heat transfer differences between the two channels with orientations of 0° and 45° are in the range of 5–26%. As a strategic aim of the present study, heat transfer correlations are derived to evaluate the centerline-averaged Nusselt numbers over two rib-roughened surfaces that permit the individual and interactive influences of convective inertia, Coriolis force, and rotating buoyancy to be quantified. As the full-field spatial heat transfer variations in the present rotating channel are not measured, the local heat transfer results generated by the present study are limited to the locations measured.