Boris Igor Palella

Prof. Boris Igor Palella

Department of Industrial engineering, University of Naples Federico II, Naples, Campania, Italy
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 October 2014 in Energy and Buildings
Verified
Journal Article
Closed access
Francesca Romana D'ambrosio AlfanoFrancesca Romana D'ambrosio Alfano
Francesca Romana D'ambrosio Alfano
BOBjarne W. Olesen
Bjarne W. Olesen
Boris Igor PalellaBoris Igor Palella
Boris Igor Palella
Giuseppe RiccioGiuseppe Riccio
Giuseppe Riccio

1 September 2013 in Building and Environment
Verified
Journal Article
Closed access
Francesca Romana D'ambrosio AlfanoFrancesca Romana D'ambrosio Alfano
Francesca Romana D'ambrosio Alfano
EIElvira Ianniello
Elvira Ianniello
Boris Igor PalellaBoris Igor Palella
Boris Igor Palella

1 July 2011 in Building and Environment
Verified
Journal Article
Closed access
Francesca Romana D'ambrosio AlfanoFrancesca Romana D'ambrosio Alfano
Francesca Romana D'ambrosio Alfano
Boris Igor PalellaBoris Igor Palella
Boris Igor Palella
Giuseppe RiccioGiuseppe Riccio
Giuseppe Riccio

1 January 2011 in Industrial Health
Verified
Journal Article
Closed access
Francesca Romana D'ambrosio AlfanoFrancesca Romana D'ambrosio Alfano
Francesca Romana D'ambrosio Alfano
Boris Igor PalellaBoris Igor Palella
Boris Igor Palella
Giuseppe RiccioGiuseppe Riccio
Giuseppe Riccio
A reliable assessment of the thermal environment should take into account the whole of the six parameters affecting the thermal sensation (air temperature, air velocity, humidity, mean radiant temperature, metabolic rate and thermo-physical properties of clothing). Anyway, the need of a quick evaluation based on few measurements and calculations has leaded to like best temperature-humidity indices instead of rational methods based on the heat balance on the human body. Among these, Canadian Humidex, preliminarily used only for weather forecasts, is becoming more and more widespread for a generalized assessment of both outdoor and indoor thermal environments. This custom arouses great controversies since using an index validated in outdoor conditions does not assure its indoor reliability. Moreover is it really possible to carry out the thermal environment assessment ignoring some of variables involved in the physiological response of the human body? Aiming to give a clear answer to these questions, this paper deals with a comparison between the assessment carried out according to the rational methods suggested by International Standards in force and the Humidex index. This combined analysis under hot stress situations (indoor and outdoor) has been preliminarily carried out; in a second phase the study deals with the indoor comfort prediction. Obtained results show that Humidex index very often leads to the underestimation of the workplace dangerousness and a poor reliability of comfort prediction when it is used in indoor situations.

1 January 2021 in Energy and Buildings
Verified
Journal Article
Closed access
LBLaura Bellia
Laura Bellia
FAFrancesca Romana D'Ambrosio Alfano
Francesca Romana D'Ambrosio Alfano
Francesca FragliassoFrancesca Fragliasso
Francesca Fragliasso
Boris Igor PalellaBoris Igor Palella
Boris Igor Palella
GRGiuseppe Riccio
Giuseppe Riccio

1 May 2013 in Building and Environment
Verified
Journal Article
Closed access
Francesca Romana D'ambrosio AlfanoFrancesca Romana D'ambrosio Alfano
Francesca Romana D'ambrosio Alfano
Marco Dell'IsolaMarco Dell'Isola
Marco Dell'Isola
Boris Igor PalellaBoris Igor Palella
Boris Igor Palella
Giuseppe RiccioGiuseppe Riccio
Giuseppe Riccio
ARAldo Russi
Aldo Russi