Early detection of arrhythmia and effective treatment can prevent deaths caused by cardiovascular disease (CVD). In clinical practice, the diagnosis is made by checking the electrocardiogram (ECG) beat-by-beat, but this is usually time-consuming and laborious. In the paper, we propose an automatic ECG classification method based on Continuous Wavelet Transform (CWT) and Convolutional Neural Network (CNN). CWT is used to decompose ECG signals to obtain different time-frequency components, and CNN is used to extract features from the 2D-scalogram composed of the above time-frequency components. Considering the surrounding R peak interval (also called RR interval) is also useful for the diagnosis of arrhythmia, four RR interval features are extracted and combined with the CNN features to input into a fully connected layer for ECG classification. By testing in the MIT-BIH arrhythmia database, our method achieves an overall performance of 70.75%, 67.47%, 68.76%, and 98.74% for positive predictive value, sensitivity, F1-score, and accuracy, respectively. Compared with existing methods, the overall F1-score of our method is increased by 4.75~16.85%. Because our method is simple and highly accurate, it can potentially be used as a clinical auxiliary diagnostic tool.
Background: Heart arrhythmia, as one of the most important cardiovascular diseases (CVDs), has gained wide attention in the past two decades. The article proposes a hybrid method for heartbeat classification via convolutional neural networks, multilayer perceptrons and focal loss. Methods: In the method, a convolution neural network is used to extract the morphological features. The reason behind this is that the morphological characteristics of patients have inter-patient variations, which makes it difficult to accurately describe using traditional hand-craft ways. Then the extracted morphological features are combined with the RR intervals features and input into the multilayer perceptron for heartbeat classification. The RR intervals features contain the dynamic information of the heartbeat. Furthermore, considering that the heartbeat classes are imbalanced and would lead to the poor performance of minority classes, a focal loss is introduced to resolve the problem in the article. Results: Tested using the MIT-BIH arrhythmia database, our method achieves an overall positive predictive value of 64.68%, sensitivity of 68.55%, f1-score of 66.09%, and accuracy of 96.27%. Compared with existing works, our method significantly improves the performance of heartbeat classification. Conclusions: Our method is simple yet effective, which is potentially used for personal automatic heartbeat classification in remote medical monitoring. The source code is provided on https://github.com/JackAndCole/Deep-Neural-Network-For-Heartbeat-Classification.
Fourier-transform infrared (FTIR) spectroscopy is a rapid and nondestructive technology for monitoring atmospheric quality. The identification of each component from the FTIR spectra is a prerequisite for the accurate quantitative analysis of gaseous pollutants. Due to the overlap of different gas absorption peaks and the interference of water vapor in the actual measurement, the existing identification methods of gas spectra have drawbacks of low identification rate and the inability to carry out real-time online analysis in atmospheric quality monitoring. In this work, independent component analysis (ICA) is applied to the spectral separation of heavily overlapped spectra of gaseous pollutants. The proposed method is validated by the analysis of mixture spectra obtained in laboratory and actual atmospheric spectra collected from stationary source. The average time consumption of separation process is less than 0.2 seconds, and the identification rate of experimental gases is up to 100%, as shown by the results of peak searching and the analysis of the correction coefficient between the separated spectra and the standard spectra database. The identification results of actual atmospheric spectra demonstrated that the proposed method can effectively identify the gaseous pollutants whose concentration changes in the measured spectra, and it is a promising qualitative spectral analysis tool that can shorten the identification time, as well as increase the identification rate. Therefore, this method can be a useful alternative to traditional qualitative identification methods for real-time online atmospheric pollutant detection.
Human key-point detection is a challenging research field in computer vision. Convolutional neural models limit the number of parameters and mine the local structure, and have made great progress in significant target detection and key-point detection. However, the features extracted by shallow layers mainly contain a lack of semantic information, while the features extracted by deep layers contain rich semantic information but a lack of spatial information that results in information imbalance and feature extraction imbalance. With the complexity of the network structure and the increasing amount of computation, the balance between the time of communication and the time of calculation highlights the importance. Based on the improvement of hardware equipment, network operation time is greatly improved by optimizing the network structure and data operation methods. However, as the network structure becomes deeper and deeper, the communication consumption between networks also increases, and network computing capacity is optimized. In addition, communication overhead is also the focus of recent attention. We propose a novel network structure PGNet, which contains three parts: pipeline guidance strategy (PGS); Cross-Distance-IoU Loss (CIoU); and Cascaded Fusion Feature Model (CFFM).
4 August 2022 in Biomedical Engineering / Biomedizinische Technik
Sleep apnea is a sleep disorder caused by weakened or suspended breathing during sleep, which seriously affects the work and health of patients. The traditional polysomnography (PSG) detection process is complicated and expensive, which has attracted researchers to explore a rapid detection method based on single-lead ECG signals. However, existing ECG-based sleep apnea detection methods have certain limitations and complexities, mainly relying on human-crafted features. To solve the problem, the paper develops a sleep apnea detection method based on a residual attention mechanism network. The method uses the RR interval signal and the R-peak signal derived from the ECG signal as input, realizes feature extraction through the residual network (ResNet), and adds the SENet attention mechanism to deepen the mining of channel features. Experimental results show that the per-segment accuracy of the proposed method can reach 86.2%. Compared with existing works, its accuracy has increased by 1.1–8.1%. These results show that the proposed residual attention network can effectively use ECG signals to quickly detect sleep apnea. Meanwhile, compared with existing works, the proposed method overcomes the limitations and complexity of human-crafted features in sleep apnea detection research.