Roger Birchmore

Mr. Roger Birchmore


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 October 2016 in Building Research & Information
Verified
Journal Article
Closed access
RBRoger Birchmore
Roger Birchmore
KDKathryn Davies
Kathryn Davies
PEPhillip Etherington
Phillip Etherington
RTRobert Tait
Robert Tait
APAndy Pivac
Andy Pivac
New Zealand dwellings have thermal conditions managed with relatively light regulation. No minimum airtightness standards exist and historical increases in required insulation levels aimed to reduce winter heating energy consumption. A consequence of this policy is an increased potential for overheating in summer. There has been a steady increase in the use of heat pumps, risking heating energy savings being outweighed by cooling energy increases. Internal temperatures and humidity were monitored in the living spaces of three unoccupied, transportable houses over all four seasons of the Auckland climate. The houses are located on the same site and are of identical construction, apart from selected interventions which were tested to explore their potential to mitigate overheating. Results indicate that overheating can be extreme and long lasting. High internal temperatures are very closely connected with solar gains. Internal temperatures reached 32°C in autumn. Roof space temperatures reached 51°C in summertime. Interventions resulted in modest improvements and an airtight construction provided a small thermal benefit. A thermal model for the houses was developed using EnergyPlus and compared with actual measurements and the interventions. Early results point to the further need to reduce solar gain, increase roof-space ventilation and increase mass, where feasible.

11 February 2015 in Buildings
Verified
Journal Article
Open access
PDF file
RBRoger Birchmore
Roger Birchmore
APAndy Pivac
Andy Pivac
RTRobert Tait
Robert Tait
New Zealand houses are known for producing sub-optimal internal thermal conditions and unacceptably high internal moisture levels. These contribute to poor levels of health, mould and can coincide with the decay of structural timber frames. A proposed solution is to provide an alternative structure utilising plywood, a vapour check on the internal face of the timber frame and an additional air gap, followed by the internal lining. The internal vapour check is designed to prevent moisture vapour diffusion from inside into the frame and to permit moisture diffusion from outside through the structure to the internal environment. Two full scale houses had temperatures, dew points and humidity levels monitored in passive, unoccupied conditions. The test case house incorporated the innovative construction solution. The control house was of identical design and location, using standard construction practice. The calculated internal moisture content profile appeared to be unrelated to the external moisture content as expected, instead following the profile of the changing internal temperature. Whilst the innovative construction appeared to prevent moisture diffusion into the structure in winter and permit it inside in summer, this resulted in a generally higher internal relative humidity than the control house.

16 May 2022 in International Journal of Building Pathology and Adaptation
Verified
Journal Article
Closed access
RBRoger Birchmore
Roger Birchmore
TBTerri-Ann Berry
Terri-Ann Berry
SWShannon L. Wallis
Shannon L. Wallis
STSteve Tsai
Steve Tsai
GHGerman Hernandez
German Hernandez
Purpose: New Zealand’s historical housing stock comprises largely single-storey detached houses, characterised by poor winter comfort with high air infiltration. Challenges with affordability and land use are shifting New Zealand’s housing stock towards double-storey, conjoined medium-density housing (MDH). Reduced external surfaces in this typology should reduce winter heat loss and infiltration, improving winter comfort and health. New concerns arise, however, regarding summertime overheating and poor indoor air quality.Design/methodology/approach: A field study was undertaken where temperature, humidity, airtightness, particulate matter (PM) and total volatile organic compounds (TVOC) were measured in two unoccupied, newly built double-storey, conjoined houses, for several weeks over summer.Findings: The reduced surface area of this typology did not reduce infiltration and demonstrated significant periods of overheating. Internal PM concentrations generally exceeded outdoor concentrations but did not exceed annual average outdoor PM10 guidelines of 20 µg m-3. Infiltration factors (Finf) were closer to more traditional houses. TVOC readings varied widely, but frequently exceeded international guidelines.Research limitations/implications: The small sample limits the applications of conclusions more widely. Recommendations to investigate a wider sample in different locations with more detailed VOC analysis over all seasons are made.Practical implications: Improvements to internal environments cannot be guaranteed by housing typology changes alone and must still involve thoughtful environmental design.Social implications: Housing typology changes may not improve internal living environments.Originality/value: A move to the new MDH typology may not achieve expectations of airtightness and thermal improvement. New challenges arise from significant overheating and high TVOC levels, which may lead to new negative health effects.