HYEONGGEUN JO

Mr. HYEONGGEUN JO

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 August 2021 in Sensors
Verified
Journal Article
Open access
PDF file
HJHYEONGGEUN JO
HYEONGGEUN JO
BPBeom Hoon Park
Beom Hoon Park
DJDo Yeong Joung
Do Yeong Joung
JJJung Ki Jo
Jung Ki Jo
JHJeong-Kyu Hoh
Jeong-Kyu Hoh
KPKwan Kyu Park
Kwan Kyu Park
Accurate measurement of bladder volume is an important tool for evaluating bladder function. In this study, we propose a wearable bladder scanner system that can continuously measure bladder volume in daily life for urinary patients who need urodynamic studies. The system consisted of a 2-D array, which included integrated forward-looking piezoelectric transducers with thin substrates. This study aims to estimate the volume of the bladder using a small number of piezoelectric transducers. A least-squares method was implemented to optimize an ellipsoid in a quadratic surface equation for bladder volume estimation. Ex-vivo experiments of a pig bladder were conducted to validate the proposed system. This work presents the potential of the approach for wearable bladder monitoring, which has similar measurement accuracy compared to the commercial bladder imaging system. The wearable bladder scanner can be improved further as electronic voiding diaries by adding a few more features to the current function.

9 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
WCWon Young Choi
Won Young Choi
HJHYEONGGEUN JO
HYEONGGEUN JO
SKSoo Won Kwon
Soo Won Kwon
YKYoung Hun Kim
Young Hun Kim
JPJoo Young Pyun
Joo Young Pyun
KPKwan Kyu Park
Kwan Kyu Park
With the development of wearable devices, strain sensors have attracted large interest for the detection of human motion, movement, and breathing. Various strain sensors consisting of stretchable conductive materials have been investigated based on resistance and capacitance differences according to the strain. However, this method requires multiple electrodes for multipoint detection. We propose a strain sensor capable of multipoint detection with a single electrode, based on the ultrasound pulse–echo method. It consists of several transmitters of carbon nanotubes (CNTs) and a single polyvinylidene fluoride receiver. The strain sensor was fabricated using CNTs embedded in stretchable polydimethylsiloxane. The received data are characterized by the different times of transmission from the CNTs of each point depending on the strain, i.e., the sensor can detect the positions of the CNTs. This study demonstrates the application of the multipoint strain sensor with a single electrode for measurements up to a strain of 30% (interval of 1%). We considered the optical and acoustic energy losses in the sensor design. In addition, to evaluate the utility of the sensor, finger bending with three-point CNTs and flexible phantom bending with six-point CNTs for the identification of an S-curve having mixed expansion and compression components were carried out.

18 August 2025 in NDT & E International
Verified
Journal Article
Closed access
HJHYEONGGEUN JO
HYEONGGEUN JO
HKHyun Su Kim
Hyun Su Kim
SGSejong Ghang
Sejong Ghang
MKMin Seok Kim
Min Seok Kim
MKMin Ho Kim
Min Ho Kim
KPKwan Kyu Park
Kwan Kyu Park

26 February 2019 in Sensors
Verified
Journal Article
Open access
PDF file
WCWon Young Choi
Won Young Choi
YKYoung Hun Kim
Young Hun Kim
HJHYEONGGEUN JO
HYEONGGEUN JO
JPJoo Young Pyun
Joo Young Pyun
SKSoo Won Kwon
Soo Won Kwon
KPKwan Kyu Park
Kwan Kyu Park
Intensive research on photoacoustics (PA) for imaging of the living human body, including the skin, vessels, and tumors, has recently been conducted. We propose a PA measurement system based on a capacitive micromachined ultrasonic transducer (CMUT) with waterless coupling, short measurement time (<1 s), backward light irradiation, and a low-profile ultrasonic receiver unit (<1 cm). We fabricate a 64-element CMUT ring array with 6.2 mm diameter and 10.4 MHz center frequency in air, and 100% yield and uniform element response. To validate the PA tissue characterization, we employ pencil lead and red ink as solid and liquid models, respectively, and a living body to target moles and vessels. The system implements a near-field imaging system consisting of a 6 mm polydimethylsiloxane (PDMS) matching layer between the object and CMUT, which has a 3.7 MHz center frequency in PDMS. Experiments were performed in a waterless contact on the PDMS and the laser was irradiated with a 1 cm diameter. The experimental results show the feasibility of this near-field PA imaging system for position and depth detection of skin, mole, vessel cells, etc. Therefore, a system applicable to a low-profile compact biomedical device is presented.

29 March 2022 in Micromachines
Verified
Journal Article
Open access
PDF file
CLChang Hoon Lee
Chang Hoon Lee
BPBeom Hoon Park
Beom Hoon Park
YKYoung Hun Kim
Young Hun Kim
HJHYEONGGEUN JO
HYEONGGEUN JO
KPKwan Kyu Park
Kwan Kyu Park
Ultrasonic particle manipulation is a noncontact method for controlling microscale objects, such as cells or microparticles, using an acoustic field. In this study, a 2D array of capacitive micromachined ultrasonic transducers (CMUTs), placed horizontally in immersion, generated ultrasonic waves in the vertical direction, and the oil’s surface increased due to the radiation force of the ultrasonic waves. In addition, the radiation force directly exerted a force on a floating particle. By measuring the movement of the reflected laser light by the moving oil surface, the height of the oil’s surface deformed by the acoustic radiation force (ARF) was measured. The ARF made a floating particle, as well as the oil’s surface, move. The particle moved radially away from the surface position above the transducer, and its velocity was determined by its position on the fluid’s surface. When a single channel was operated, it moved 0.4 mm at an average speed of 90 μm/s, and when two adjacent channels were operated, it moved 1.2 mm at a speed of 272 μm/s. The particles moved in any direction on the surface of the oil by controlling the actuation channel using an electrical switch.

1 April 2020 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
SKSoo Won Kwon
Soo Won Kwon
WCWon Young Choi
Won Young Choi
HJHYEONGGEUN JO
HYEONGGEUN JO
KPKwan Kyu Park
Kwan Kyu Park
An ultrasound transducer was fabricated by dropping a multi-walled carbon nanotube solution containing a mixture of carbon nanotubes and ethoxyethanol directly on the surface of polyethylene microspheres. The frequency modulation depended on the diameter of the polyethylene microspheres. To investigate this relationship, three types of polyethylene microspheres with different diameters were used in simulations and experiments. These specimens were attached to polydimethylsiloxane and glass plates. A comparison revealed that the 50 μm diameter polyethylene spheres coated with carbon nanotubes had the highest ultrasound frequency. This work showed that smaller polyethylene microspheres generate higher ultrasound frequencies.