Luca Lonini

Dr. Luca Lonini


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 January 2022 in Digital Biomarkers
Verified
Journal Article
Open access
PDF file
LLLuca Lonini
Luca Lonini
YMYaejin Moon
Yaejin Moon
KEKyle Embry
Kyle Embry
RCRonald James Cotton
Ronald James Cotton
Kelly MckenzieKelly Mckenzie
Kelly Mckenzie
AJArun Jayaraman
Arun Jayaraman
Recent advancements in deep learning have produced significant progress in markerless human pose estimation, making it possible to estimate human kinematics from single camera videos without the need for reflective markers and specialized labs equipped with motion capture systems. Such algorithms have the potential to enable the quantification of clinical metrics from videos recorded with a handheld camera. Here we used DeepLabCut, an open-source framework for markerless pose estimation, to fine-tune a deep network to track 5 body keypoints (hip, knee, ankle, heel, and toe) in 82 below-waist videos of 8 patients with stroke performing overground walking during clinical assessments. We trained the pose estimation model by labeling the keypoints in 2 frames per video and then trained a convolutional neural network to estimate 5 clinically relevant gait parameters (cadence, double support time, swing time, stance time, and walking speed) from the trajectory of these keypoints. These results were then compared to those obtained from a clinical system for gait analysis (GAITRite®, CIR Systems). Absolute accuracy (mean error) and precision (standard deviation of error) for swing, stance, and double support time were within 0.04 ± 0.11 s; Pearson’s correlation with the reference system was moderate for swing times (r = 0.4–0.66), but stronger for stance and double support time (r = 0.93–0.95). Cadence mean error was −0.25 steps/min ± 3.9 steps/min (r = 0.97), while walking speed mean error was −0.02 ± 0.11 m/s (r = 0.92). These preliminary results suggest that single camera videos and pose estimation models based on deep networks could be used to quantify clinically relevant gait metrics in individuals poststroke, even while using assistive devices in uncontrolled environments. Such development opens the door to applications for gait analysis both inside and outside of clinical settings, without the need of sophisticated equipment.

11 February 2021 in IEEE Journal of Translational Engineering in Health and Medicine
Verified
Journal Article
Open access
LLLuca Lonini
Luca Lonini
NSNicholas Shawen
Nicholas Shawen
OBOlivia Botonis
Olivia Botonis
MFMichael Fanton
Michael Fanton
CJChandrasekaran Jayaraman
Chandrasekaran Jayaraman
AJArun Jayaraman
Arun Jayaraman
Objective: Controlling the spread of the COVID-19 pandemic largely depends on scaling up the testing infrastructure for identifying infected individuals. Consumer-grade wearables may present a solution to detect the presence of infections in the population, but the current paradigm requires collecting physiological data continuously and for long periods of time on each individual, which poses limitations in the context of rapid screening. Technology: Here, we propose a novel paradigm based on recording the physiological responses elicited by a short (~2 minutes) sequence of activities (i.e. “snapshot”), to detect symptoms associated with COVID-19. We employed a novel body-conforming soft wearable sensor placed on the suprasternal notch to capture data on physical activity, cardio-respiratory function, and cough sounds. Results: We performed a pilot study in a cohort of individuals (n=14) who tested positive for COVID-19 and detected altered heart rate, respiration rate and heart rate variability, relative to a group of healthy individuals (n=14) with no known exposure. Logistic regression classifiers were trained on individual and combined sets of physiological features (heartbeat and respiration dynamics, walking cadence, and cough frequency spectrum) at discriminating COVID-positive participants from the healthy group. Combining features yielded an AUC of 0.94 (95% CI=[0.92, 0.96]) using a leave-one-subject-out cross validation scheme. Conclusions and Clinical Impact: These results, although preliminary, suggest that a sensor-based snapshot paradigm may be a promising approach for non-invasive and repeatable testing to alert individuals that need further screening.

1 January 2013 in Frontiers in Neurorobotics
Verified
Journal Article
Open access
LLLuca Lonini
Luca Lonini
SFSébastien Forestier
Sébastien Forestier
CTCéline Teulière
Céline Teulière
YZYu Zhao
Yu Zhao
BSBertram E. Shi
Bertram E. Shi
JTJochen Triesch
Jochen Triesch
The efficient coding hypothesis posits that sensory systems of animals strive to encode sensory signals efficiently by taking into account the redundancies in them. This principle has been very successful in explaining response properties of visual sensory neurons as adaptations to the statistics of natural images. Recently, we have begun to extend the efficient coding hypothesis to active perception through a form of intrinsically motivated learning: a sensory model learns an efficient code for the sensory signals while a reinforcement learner generates movements of the sense organs to improve the encoding of the signals. To this end, it receives an intrinsically generated reinforcement signal indicating how well the sensory model encodes the data. This approach has been tested in the context of binocular vison, leading to the autonomous development of disparity tuning and vergence control. Here we systematically investigate the robustness of the new approach in the context of a binocular vision system implemented on a robot. Robustness is an important aspect that reflects the ability of the system to deal with unmodeled disturbances or events, such as insults to the system that displace the stereo cameras. To demonstrate the robustness of our method and its ability to self-calibrate, we introduce various perturbations and test if and how the system recovers from them. We find that (1) the system can fully recover from a perturbation that can be compensated through the system's motor degrees of freedom, (2) performance degrades gracefully if the system cannot use its motor degrees of freedom to compensate for the perturbation, and (3) recovery from a perturbation is improved if both the sensory encoding and the behavior policy can adapt to the perturbation. Overall, this work demonstrates that our intrinsically motivated learning approach for efficient coding in active perception gives rise to a self-calibrating perceptual system of high robustness.

11 October 2017 in JMIR mHealth and uHealth
Verified
Journal Article
Open access
NSNicholas Shawen
Nicholas Shawen
LLLuca Lonini
Luca Lonini
CMChaithanya Krishna Mummidisetty
Chaithanya Krishna Mummidisetty
ISIlona Shparii
Ilona Shparii
MAMark V. Albert
Mark V. Albert
AJArun Jayaraman
Arun Jayaraman
Automatically detecting falls with mobile phones provides an opportunity for rapid response to injuries and better knowledge of what precipitated the fall and its consequences. This is beneficial for populations that are prone to falling, such as people with lower limb amputations. Prior studies have focused on fall detection in able-bodied individuals using data from a laboratory setting. Such approaches may provide a limited ability to detect falls in amputees and in real-world scenarios. The aim was to develop a classifier that uses data from able-bodied individuals to detect falls in individuals with a lower limb amputation, while they freely carry the mobile phone in different locations and during free-living. We obtained 861 simulated indoor and outdoor falls from 10 young control (non-amputee) individuals and 6 individuals with a lower limb amputation. In addition, we recorded a broad database of activities of daily living, including data from three participants' free-living routines. Sensor readings (accelerometer and gyroscope) from a mobile phone were recorded as participants freely carried it in three common locations-on the waist, in a pocket, and in the hand. A set of 40 features were computed from the sensors data and four classifiers were trained and combined through stacking to detect falls. We compared the performance of two population-specific models, trained and tested on either able-bodied or amputee participants, with that of a model trained on able-bodied participants and tested on amputees. A simple threshold-based classifier was used to benchmark our machine-learning classifier. The accuracy of fall detection in amputees for a model trained on control individuals (sensitivity: mean 0.989, 1.96*standard error of the mean [SEM] 0.017; specificity: mean 0.968, SEM 0.025) was not statistically different (P=.69) from that of a model trained on the amputee population (sensitivity: mean 0.984, SEM 0.016; specificity: mean 0.965, SEM 0.022). Detection of falls in control individuals yielded similar results (sensitivity: mean 0.979, SEM 0.022; specificity: mean 0.991, SEM 0.012). A mean 2.2 (SD 1.7) false alarms per day were obtained when evaluating the model (vs mean 122.1, SD 166.1 based on thresholds) on data recorded as participants carried the phone during their daily routine for two or more days. Machine-learning classifiers outperformed the threshold-based one (P<.001). A mobile phone-based fall detection model can use data from non-amputee individuals to detect falls in individuals walking with a prosthesis. We successfully detected falls when the mobile phone was carried across multiple locations and without a predetermined orientation. Furthermore, the number of false alarms yielded by the model over a longer period of time was reasonably low. This moves the application of mobile phone-based fall detection systems closer to a real-world use case scenario.

31 March 2016 in Journal of NeuroEngineering and Rehabilitation
Verified
Journal Article
Open access
PDF file
LLLuca Lonini
Luca Lonini
NSNicholas Shawen
Nicholas Shawen
KSKathleen Scanlan
Kathleen Scanlan
William Zev RymerWilliam Zev Rymer
William Zev Rymer
KKKonrad P. Kording
Konrad P. Kording
AJArun Jayaraman
Arun Jayaraman
Clinical scores for evaluating walking skills with lower limb exoskeletons are often based on a single variable, such as distance walked or speed, even in cases where a host of features are measured. We investigated how to combine multiple features such that the resulting score has high discriminatory power, in particular with few patients. A new score is introduced that allows quantifying the walking ability of patients with spinal cord injury when using a powered exoskeleton. Four spinal cord injury patients were trained to walk over ground with the ReWalk™ exoskeleton. Body accelerations during use of the device were recorded by a wearable accelerometer and 4 features to evaluate walking skills were computed. The new score is the Gaussian naïve Bayes surprise, which evaluates patients relative to the features’ distribution measured in 7 expert users of the ReWalk™. We compared our score based on all the features with a standard outcome measure, which is based on number of steps only. All 4 patients improved over the course of training, as their scores trended towards the expert users’ scores. The combined score (Gaussian naïve surprise) was considerably more discriminative than the one using only walked distance (steps). At the end of training, 3 out of 4 patients were significantly different from the experts, according to the combined score (p < .001, Wilcoxon Signed-Rank Test). In contrast, all but one patient were scored as experts when number of steps was the only feature. Integrating multiple features could provide a more robust metric to measure patients’ skills while they learn to walk with a robotic exoskeleton. Testing this approach with other features and more subjects remains as future work.

10 August 2017 in JMIR Rehabilitation and Assistive Technologies
Verified
Journal Article
Open access
LLLuca Lonini
Luca Lonini
AGAakash Gupta
Aakash Gupta
SDSusan Deems-Dluhy
Susan Deems-Dluhy
SHShenan Hoppe-Ludwig
Shenan Hoppe-Ludwig
KKKonrad Kording
Konrad Kording
AJArun Jayaraman
Arun Jayaraman
Journal of Medical Internet Research - International Scientific Journal for Medical Research, Information and Communication on the Internet