Dakun Lai

Prof. Dakun Lai

School of Electronic Science and Engineering, University of Electronic Science and Technology of China, Chengdu 610054, China
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 June 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
Md Belal Bin HeyatMd Belal Bin Heyat
Md Belal Bin Heyat
FAFaijan Akhtar
Faijan Akhtar
SASyed Jafar Abbas
Syed Jafar Abbas
Mohammed Al-SaremMohammed Al-Sarem
Mohammed Al-Sarem
AAAbdulrahman Al-Qarafi
Abdulrahman Al-Qarafi
KWKaishun Wu
Kaishun Wu
In the modern world, wearable smart devices are continuously used to monitor people’s health. This study aims to develop an automatic mental stress detection system for researchers based on Electrocardiogram (ECG) signals from smart T-shirts using machine learning classifiers. We used 20 subjects, including 10 from mental stress (after twelve hours of continuous work in the laboratory) and 10 from normal (after completing the sleep or without any work). We also applied three scoring techniques: Chalder Fatigue Scale (CFS), Specific Fatigue Scale (SFS), Depression, Anxiety, and Stress Scale (DASS), to confirm the mental stress. The total duration of ECG recording was 1800 min, including 1200 min during mental stress and 600 min during normal. We calculated two types of features, such as demographic and extracted by ECG signal. In addition, we used Decision Tree (DT), Naive Bayes (NB), Random Forest (RF), and Logistic Regression (LR) to classify the intra-subject (mental stress and normal) and inter-subject classification. The DT leave-one-out model has better performance in terms of recall (93.30%), specificity (96.70%), precision (94.40%), accuracy (93.30%), and F1 (93.50%) in the intra-subject classification. Additionally, The classification accuracy of the system in classifying inter-subjects is 94.10% when using a DT classifier. However, our findings suggest that the wearable smart T-shirt based on the DT classifier may be used in big data applications and health monitoring. Mental stress can lead to mitochondrial dysfunction, oxidative stress, blood pressure, cardiovascular disease, and various health problems. Therefore, real-time ECG signals help assess cardiovascular and related risk factors in the initial stage based on machine learning techniques.

11 August 2022 in Biosensors
Verified
Journal Article
Open access
PDF file
HUHadaate Ullah
Hadaate Ullah
MMMahdi H. Miraz
Mahdi H. Miraz
Geoffrey WillGeoffrey Will
Geoffrey Will
Mohammad Rezaul KarimMohammad Rezaul Karim
Mohammad Rezaul Karim
TPTaisong Pan
Taisong Pan
YLYuan Lin
Yuan Lin
Over the past several years, wearable electrophysiological sensors with stretchability have received significant research attention because of their capability to continuously monitor electrophysiological signals from the human body with minimal body motion artifacts, long-term tracking, and comfort for real-time health monitoring. Among the four different sensors, i.e., piezoresistive, piezoelectric, iontronic, and capacitive, capacitive sensors are the most advantageous owing to their reusability, high durability, device sterilization ability, and minimum leakage currents between the electrode and the body to reduce the health risk arising from any short circuit. This review focuses on the development of wearable, flexible capacitive sensors for monitoring electrophysiological conditions, including the electrode materials and configuration, the sensing mechanisms, and the fabrication strategies. In addition, several design strategies of flexible/stretchable electrodes, body-to-electrode signal transduction, and measurements have been critically evaluated. We have also highlighted the gaps and opportunities needed for enhancing the suitability and practical applicability of wearable capacitive sensors. Finally, the potential applications, research challenges, and future research directions on stretchable and wearable capacitive sensors are outlined in this review.

1 July 2019 in IEEE Access
Verified
Journal Article
Open access
Dakun LaiDakun Lai
Dakun Lai
YZYifei Zhang
Yifei Zhang
XZXinshu Zhang
Xinshu Zhang
YSYe Su
Ye Su
Md Belal Bin HeyatMd Belal Bin Heyat
Md Belal Bin Heyat
Early risk identification of an unexpected sudden cardiac death (SCD) in a person who is suffering malignant ventricular arrhythmias is highly significant for timely intervention and increasing the survival rate. For this purpose, we have presented an automated strategy for prediction of SCD with a high-level accuracy by using measurable arrhythmic markers in this paper. The set of arrhythmic parameters includes three repolarization interval ratios, such as T p T e /QT, JT p /JT e , and T p T e /JT p and two conduction-repolarization markers, such as T p T e /QRS and T p T e /(QT×QRS). Each of them is calculated directly from the detected QRS complex waves and T-wave of electrocradiogram (ECG) signals. Then, all calculated markers are used for the automatical classification of normal and SCD risk groups by employing machine learning classifiers, such as k-nearest neighbor (KNN), decision tree (DT), Naive Bayes (NB), support vector machine (SVM), and random forest (RF). The effectiveness and usefulness of the proposed method is evaluated using a database of measured ECG data acquired from 28 SCD and 18 normal patients. For the automated strategy, the set of five arrhythmic risk markers can predict SCD in less than one second with an average accuracy of 98.91% (KNN), 98.70% (SVM), 98.99% (DT), 97.46% (NB), and 99.49% (RF) for 30 minutes before the occurrence of SCD. Moreover, a practical and straightforward SCD index (SCDI) through a judicious integration of these markers is also proposed by using the Student's t-test. The obtained SCDIs are 1.2058 ± 0.0795 and 1.7619 ± 0.1902 for normal and SCD patients, respectively, which provide a sufficient discrimination degree with a p-value of 6.5061e-35. The present results show that both the automated classifier and the integrated SCDI can predict the SCD up to 30 minutes earlier, and that these predictions could be more practical and efficient if applied in portable smart devices with real-time requirements in hospital settings or at home.

11 July 2019 in IEEE Access
Verified
Journal Article
Open access
Md Belal Bin HeyatMd Belal Bin Heyat
Md Belal Bin Heyat
Dakun LaiDakun Lai
Dakun Lai
Faez Iqbal KhanFaez Iqbal Khan
Faez Iqbal Khan
YZYifei Zhang
Yifei Zhang
Lack of sleep causes many sleep disorders such as nocturnal frontal lobe epilepsy, narcolepsy, bruxism, sleep apnea, insomnia, periodic limb movement disorder, and rapid eye movement behavioral disorder. Out of all, bruxism is a common behavior, which is found in 8-31% of the population. Bruxism is a sleep disorder in which individuals involuntarily grinds and clenches the teeth. The main aim of this work is to detect sleep bruxism by analyzing the electroencephalogram (EEG) spectrum analysis of the change in the domain of different stages of sleep. The present research was performed in different stages such as collection of the data, preprocessing of the EEG signal, analysis of the C4-P4 and C4-A1 channels, comparison between healthy humans and bruxism patients, and classification using decision tree method. In this study, the channels C4-P4 and C4-A1 of the EEG signal were combined for the detection of bruxism by using Welch technique, which mainly focused on two sleep stages such as S1 and rapid eye movement. The total number of EEG channels of healthy humans and bruxism patients analyzed in this work were 15 and 18, respectively. The results showed that the individual accuracy of the C4-P4 and C4-A1 channels was 81.70% and 74.11%, respectively. The combined accuracy of both C4-P4 and C4-A1 channels was 81.25%. The specificity of combined result was higher than individual. In addition, the value of theta activity during detection is consistent throughout the period, and the accuracy of S1 stage is better than rapid eye movement stage. We proposed that the theta activity of S1 could be taken for the detection of bruxism. The proposed approach in the detection of the bruxism is negligible in noise as it is in mathematical form and has taken very less time as compared with the traditional systems. The present research work would provide a fast and effective detection system of the sleep bruxism with high accuracy for medical big data applications.
1

22 October 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Md Belal Bin HeyatMd Belal Bin Heyat
Md Belal Bin Heyat
FAIJAN AKHTARFAIJAN AKHTAR
FAIJAN AKHTAR
DKDr. Asif khan
Dr. Asif khan
Alam NoorAlam Noor
Alam Noor
BBBilel Benjdira
Bilel Benjdira
Dakun LaiDakun Lai
Dakun Lai
Bruxism is a sleep disorder in which the patient clinches and gnashes their teeth. Bruxism detection using traditional methods is time-consuming, cumbersome, and expensive. Therefore, an automatic tool to detect this disorder will alleviate the doctor workload and give valuable help to patients. In this paper, we targeted this goal and designed an automatic method to detect bruxism from the physiological signals using a novel hybrid classifier. We began with data collection. Then, we performed the analysis of the physiological signals and the estimation of the power spectral density. After that, we designed the novel hybrid classifier to enable the detection of bruxism based on these data. The classification of the subjects into “healthy” or “bruxism” from the electroencephalogram channel (C4-A1) obtained a maximum specificity of 92% and an accuracy of 94%. Besides, the classification of the sleep stages such as the wake (w) stage and rapid eye movement (REM) stage from the electrocardiogram channel (ECG1-ECG2) obtained a maximum specificity of 86% and an accuracy of 95%. The combined bruxism classification and the sleep stages classification from the electroencephalogram channel (C4-P4) obtained a maximum specificity of 90% and an accuracy of 97%. The results show that more accurate bruxism detection is achieved by exploiting the electroencephalogram signal (C4-P4). The present work can be applied for home monitoring systems for bruxism detection.

21 June 2019 in IEEE Access
Verified
Journal Article
Open access
Dakun LaiDakun Lai
Dakun Lai
Md Belal Bin HeyatMd Belal Bin Heyat
Md Belal Bin Heyat
Faez Iqbal KhanFaez Iqbal Khan
Faez Iqbal Khan
YZYifei Zhang
Yifei Zhang
Bruxism is a sleep syndrome, in which individual involuntarily grinding and clenching the teeth. If sleep does not complete properly, then it generates many disorders such as bruxism, insomnia, sleep apnea, narcolepsy, rapid eye movement behavioral disorder, and nocturnal frontal lobe epilepsy. The aim of this research is to draw the results in the form of signal spectrum analysis of the changes in the domain of different stages of sleep. The present research completed in three stages such as collection of the data, analysis of the electroencephalogram (EEG) signal, and comparative analysis between bruxism patients and normal subjects. Importantly, the channels EMG1-EMG2 and ECG1-ECG2 of the EEG signal were combined for the prognosis of bruxism by using power spectral density, which mainly focused on two sleep stages such as wake (W) and rapid eye movement (REM). The total number of one-minute EEG recordings from bruxism patients and normal subjects analyzed in this work were 149 and 95, respectively. The obtained results show that the average normalized values of the power spectral density of the EMG1-EMG2 and ECG1-ECG2 channels during REM and W sleep stages are several folds higher in case of the bruxism than those in the normal. Moreover, the proposed power spectral density based method by using the decision tree classifier shows a higher accuracy for prognosis of sleep bruxism in comparison with previous works. Additionally, the proposed approach in the prognosis of the bruxism are noise free and accurate as it is in mathematical form and has taken very less time as compared with the traditional systems. The present research work would provide a fast and effective prognosis system of the human bruxism with high accuracy for medical applications.