Eugene D. Skouras

Prof. Dr. Eugene D. Skouras

Department of Mechanical Engineering, University of the Peloponnese, Patras, Greece
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in European Journal of Mechanics - B/Fluids
Verified
Journal Article
Closed access
GBGeorgios Bourantas
Georgios Bourantas
ESEugene D. Skouras
Eugene D. Skouras
VLV.C. Loukopoulos
V.C. Loukopoulos
VBV.N. Burganos
V.N. Burganos

31 March 2010 in Microfluidics and Nanofluidics
Verified
Journal Article
Closed access
PDF file
VMVasileios Michalis
Vasileios Michalis
AKAlexandros Kalarakis
Alexandros Kalarakis
ESEugene D. Skouras
Eugene D. Skouras
VBVasilis N Burganos
Vasilis N Burganos

1 November 2009 in Journal of Computational Physics
Verified
Journal Article
Open access
GBGeorgios Bourantas
Georgios Bourantas
ESEugene D. Skouras
Eugene D. Skouras
VLV.C. Loukopoulos
V.C. Loukopoulos
GNG.C. Nikiforidis
G.C. Nikiforidis

21 August 2007 in Medical Engineering & Physics
Verified
Journal Article
Open access
GKGeorge C. Kagadis
George C. Kagadis
ESEugene D. Skouras
Eugene D. Skouras
GBGeorgios Bourantas
Georgios Bourantas
CPChristakis A. Paraskeva
Christakis A. Paraskeva
KKKonstantinos Katsanos
Konstantinos Katsanos
GNGeorge C. Nikiforidis
George C. Nikiforidis
The present study reports on computational fluid dynamics in the case of severe renal artery stenosis (RAS). An anatomically realistic model of a renal artery was reconstructed from CT scans, and used to conduct CFD simulations of blood flow across RAS. The recently developed shear stress transport (SST) turbulence model was pivotally applied in the simulation of blood flow in the region of interest. Blood flow was studied in vivo under the presence of RAS and subsequently in simulated cases before the development of RAS, and after endovascular stent implantation. The pressure gradients in the RAS case were many orders of magnitude larger than in the healthy case. The presence of RAS increased flow resistance, which led to considerably lower blood flow rates. A simulated stent in place of the RAS decreased the flow resistance at levels proportional to, and even lower than, the simulated healthy case without the RAS. The wall shear stresses, differential pressure profiles, and net forces exerted on the surface of the atherosclerotic plaque at peak pulse were shown to be of relevant high distinctiveness, so as to be considered potential indicators of hemodynamically significant RAS.

1 June 2005 in Journal of Hydrology
Verified
Journal Article
Closed access
PGPetros Gaganis
Petros Gaganis
ESEugene D. Skouras
Eugene D. Skouras
MTM.A. Theodoropoulou
M.A. Theodoropoulou
CTChristos Tsakiroglou
Christos Tsakiroglou
VBV.N. Burganos
V.N. Burganos

3 May 2012 in Transport in Porous Media
Verified
Journal Article
Closed access
PDF file
AKAlexandros Kalarakis
Alexandros Kalarakis
VMVasileios Michalis
Vasileios Michalis
ESEugene D. Skouras
Eugene D. Skouras
VBVasilis N Burganos
Vasilis N Burganos