Elisabeth Elje

Ms. Elisabeth Elje

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 March 2020 in Nanomaterials
Verified
Journal Article
Open access
PDF file
EEElisabeth Elje
Elisabeth Elje
EMEspen Mariussen
Espen Mariussen
OMOscar H. Moriones
Oscar H. Moriones
Neus G. BastúsNeus G. Bastús
Neus G. Bastús
VPVictor Puntes
Victor Puntes
Elise Rundén-PranElise Rundén-Pran
Elise Rundén-Pran
(1) In compliance with the 3Rs policy to reduce, refine and replace animal experiments, the development of advanced in vitro models is needed for nanotoxicity assessment. Cells cultivated in 3D resemble organ structures better than 2D cultures. This study aims to compare cytotoxic and genotoxic responses induced by titanium dioxide (TiO2), silver (Ag) and zinc oxide (ZnO) nanoparticles (NPs) in 2D monolayer and 3D spheroid cultures of HepG2 human liver cells. (2) NPs were characterized by electron microscopy, dynamic light scattering, laser Doppler anemometry, UV-vis spectroscopy and mass spectrometry. Cytotoxicity was investigated by the alamarBlue assay and confocal microscopy in HepG2 monolayer and spheroid cultures after 24 h of NP exposure. DNA damage (strand breaks and oxidized base lesions) was measured by the comet assay. (3) Ag-NPs were aggregated at 24 h, and a substantial part of the ZnO-NPs was dissolved in culture medium. Ag-NPs induced stronger cytotoxicity in 2D cultures (EC50 3.8 µg/cm2) than in 3D cultures (EC50 > 30 µg/cm2), and ZnO-NPs induced cytotoxicity to a similar extent in both models (EC50 10.1–16.2 µg/cm2). Ag- and ZnO-NPs showed a concentration-dependent genotoxic effect, but the effect was not statistically significant. TiO2-NPs showed no toxicity (EC50 > 75 µg/cm2). (4) This study shows that the HepG2 spheroid model is a promising advanced in vitro model for toxicity assessment of NPs.

29 July 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
LCLaura Maria Azzurra Azzurra Camassa
Laura Maria Azzurra Azzurra Camassa
EEElisabeth Elje
Elisabeth Elje
EMEspen Mariussen
Espen Mariussen
ELEleonora Marta Longhin
Eleonora Marta Longhin
Maria DusinskaMaria Dusinska
Maria Dusinska
Elise Rundén-PranElise Rundén-Pran
Elise Rundén-Pran
Advanced in vitro models are needed to support next-generation risk assessment (NGRA), moving from hazard assessment based mainly on animal studies to the application of new alternative methods (NAMs). Advanced models must be tested for hazard assessment of nanomaterials (NMs). The aim of this study was to perform an interlaboratory trial across two laboratories to test the robustness of and optimize a 3D lung model of human epithelial A549 cells cultivated at the air–liquid interface (ALI). Potential change in sensitivity in hazard identification when adding complexity, going from monocultures to co- and tricultures, was tested by including human endothelial cells EA.hy926 and differentiated monocytes dTHP-1. All models were exposed to NM-300K in an aerosol exposure system (VITROCELL® cloud-chamber). Cyto- and genotoxicity were measured by AlamarBlue and comet assay. Cellular uptake was investigated with transmission electron microscopy. The models were characterized by confocal microscopy and barrier function tested. We demonstrated that this advanced lung model is applicable for hazard assessment of NMs. The results point to a change in sensitivity of the model by adding complexity and to the importance of detailed protocols for robustness and reproducibility of advanced in vitro models.

19 January 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
EEElisabeth Elje
Elisabeth Elje
EMEspen Mariussen
Espen Mariussen
EMErin McFadden
Erin McFadden
Maria DusinskaMaria Dusinska
Maria Dusinska
Elise Rundén-PranElise Rundén-Pran
Elise Rundén-Pran
For the next-generation risk assessment (NGRA) of chemicals and nanomaterials, new approach methodologies (NAMs) are needed for hazard assessment in compliance with the 3R’s to reduce, replace and refine animal experiments. This study aimed to establish and characterize an advanced respiratory model consisting of human epithelial bronchial BEAS-2B cells cultivated at the air–liquid interface (ALI), both as monocultures and in cocultures with human endothelial EA.hy926 cells. The performance of the bronchial models was compared to a commonly used alveolar model consisting of A549 in monoculture and in coculture with EA.hy926 cells. The cells were exposed at the ALI to nanosilver (NM-300K) in the VITROCELL® Cloud. After 24 h, cellular viability (alamarBlue assay), inflammatory response (enzyme-linked immunosorbent assay), DNA damage (enzyme-modified comet assay), and chromosomal damage (cytokinesis-block micronucleus assay) were measured. Cytotoxicity and genotoxicity induced by NM-300K were dependent on both the cell types and model, where BEAS-2B in monocultures had the highest sensitivity in terms of cell viability and DNA strand breaks. This study indicates that the four ALI lung models have different sensitivities to NM-300K exposure and brings important knowledge for the further development of advanced 3D respiratory in vitro models for the most reliable human hazard assessment based on NAMs.

19 May 2023 in Bioelectrochemistry
Verified
Journal Article
Open access
YKYvonne Kohl
Yvonne Kohl
NWNicola William
Nicola William
EEElisabeth Elje
Elisabeth Elje
NBNadine Backes
Nadine Backes
MRMario Rothbauer
Mario Rothbauer
andrew nelsonandrew nelson
andrew nelson
This study compares the performance and output of an electrochemical phospholipid membrane platform against respective in vitro cell-based toxicity testing methods using three toxicants of different biological action (chlorpromazine (CPZ), colchicine (COL) and methyl methanesulphonate (MMS)). Human cell lines from seven different tissues (lung, liver, kidney, placenta, intestine, immune system) were used to validate this physicochemical testing system. For the cell-based systems, the effective concentration at 50 % cell death (EC50) values are calculated. For the membrane sensor, a limit of detection (LoD) value was extracted as a quantitative parameter describing the minimum concentration of toxicant which significantly affects the structure of the phospholipid sensor membrane layer. LoD values were found to align well with the EC50 values when acute cell viability was used as an end-point and showed a similar toxicity ranking of the tested toxicants. Using the colony forming efficiency (CFE) or DNA damage as end-point, a different order of toxicity ranking was observed. The results of this study showed that the electrochemical membrane sensor generates a parameter relating to biomembrane damage, which is the predominant factor in decreasing cell viability when in vitro models are acutely exposed to toxicants. These results lead the way to using electrochemical membrane-based sensors for rapid relevant preliminary toxicity screens.

24 November 2024 in Nanomaterials
Verified
Journal Article
Open access
PDF file
EEElisabeth Elje
Elisabeth Elje
LCLaura Maria Azzurra Azzurra Camassa
Laura Maria Azzurra Azzurra Camassa
SSSergey Shaposhnikov
Sergey Shaposhnikov
KAKristine Haugen Anmarkrud
Kristine Haugen Anmarkrud
ØSØivind Skare
Øivind Skare
Elise Rundén-PranElise Rundén-Pran
Elise Rundén-Pran
This study represents an attempt toward the standardization of pulmonary NAMs and the development of a novel approach for toxicity testing of nanomaterials. Laboratory comparisons are challenging yet essential for identifying existing limitations and proposing potential solutions. Lung cells cultivated and exposed at the air-liquid interface (ALI) more accurately represent the physiology of human lungs and pulmonary exposure scenarios than submerged cell and exposure models. A triculture cell model system was used, consisting of human A549 lung epithelial cells and differentiated THP-1 macrophages on the apical side, with EA.hy926 endothelial cells on the basolateral side. The cells were exposed to silver nanoparticles NM-300K for 24 h. The model used here showed to be applicable for assessing the hazards of nanomaterials and chemicals, albeit with some limitations. Cellular viability was measured using the alamarBlue assay, DNA damage was assessed with the enzyme-modified comet assay, and the expression of 40 genes related to cell viability, inflammation, and DNA damage response was evaluated through RT2 gene expression profiling. Despite harmonized protocols used in the two independent laboratories, however, some methodological challenges could affect the results, including sensitivity and reproducibility of the model.