Jiali Xing

Dr. Jiali Xing


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2022 in Food Additives & Contaminants: Part A
Verified
Journal Article
Closed access
JXJiali Xing
Jiali Xing
YLYang Li
Yang Li
RZRuihang Zheng
Ruihang Zheng
HSHao Shen
Hao Shen
XXXiaorong Xu
Xiaorong Xu
WYWeirong Yao
Weirong Yao
Phenolic compounds can cause health problems in humans through the food chain. Considering that fish play an important role in human diets, we established a rapid, simple and high-throughput method for the determination of 18 phenolic compounds in fish based on a modified QuEChERS sample preparation method combined with GC-MS. The average recovery of the 18 phenolic compounds was 81.3–116% at 3 spiked levels, and the relative standard deviations, RSDr and RSDwR, were in the range of 1.1–11.3% and 1.5–12.2%, respectively. The limit of detection was 2.0–10.1 μg/kg. Satisfactory linear relationships (R2 > 0.998) were observed for the phenolic compounds in their corresponding concentration ranges. Moreover, the established method exhibited a high sensitivity, good stability, and reliability. The development of this method has an important theoretical and practical significance for establishing standards and to control the residue levels of phenolic compounds in fish.

17 February 2023 in Foods
Verified
Journal Article
Open access
PDF file
JXJiali Xing
Jiali Xing
XWXi Wu
Xi Wu
XXXiaorong Xu
Xiaorong Xu
HCHai Cheng
Hai Cheng
JSJian Shen
Jian Shen
YLYu Liu
Yu Liu
Robust and sensitive ultrahigh-performance liquid chromatography–tandem mass spectrometry (UPLC–MS/MS) combined with the quick, easy, cheap, effective, rugged, and safe (QuEChERS) method was applied for the detection of seven Alternaria toxins (ATs) in tuberous crops. The influence of tuber conditions (fresh, germinated, and moldy) during storage on the concentration of the seven ATs is also investigated. ATs were extracted with acetonitrile under acidic conditions and purified with a C18 adsorbent. ATs were scanned with electrospray ionization (positive/negative ion) dynamic switching and detected in MRM mode. Calibration curve analysis results reveal good linear relationships in all toxin concentration ranges (R2 > 0.99). The limit of detection and limit of quantification were 0.25–0.70 and 0.83–2.31 μg/kg, respectively. The average recoveries of the seven ATs were 83.2–104% with intra-/inter-day precision at 3.52–6.55% and 4.02–7.26%, respectively. The developed method provided adequate selectivity, sensitivity, and precision in detecting the seven ATs at trace levels, and dispensed with standard addition or matrix-matched calibration to compensate for matrix effects. ATs in the fresh, germinated, and moldy samples of tuberous crops in storage (taro, potato, sweet potato, yam, cassava) were analyzed with this method, and the concentrations were 2.01–14.51 μg/kg and significantly increased with storage duration. ALS was detected in most samples, whereas no quantities of ALT and ATX-I were detected. AME was often detected in combination with AOH in sweet potatoes. TeA and Ten were mostly detected in taro, potato, and yam. The established method could be used for the simultaneous detection and quantification of multicomponent toxins in elaborate matrices.

4 July 2022 in Chinese Journal of Chromatography
Verified
Journal Article
Open access
YMYinghua Mu
Yinghua Mu
JXJiali Xing
Jiali Xing
JSJian Shen
Jian Shen
LYLu Ying
Lu Ying
LMLingyan Mao
Lingyan Mao
XWXi Wu
Xi Wu
With the increasing use of chlorine-containing pesticides, hypochlorous acid disinfection water as well as aquatic product insecticides and fungicides are widely used in the cultivation of fish. This has led to the contamination of fish by chlorophenol compounds. However, currently, there is no standard method for the simultaneous determination of 19 chlorophenol compounds in fish. In this study, the optimum chromatography and mass spectrometry conditions were determined by investigating the instrument parameters. The 19 chlorophenol compounds were well separated using the DB-5MS capillary chromatographic column (30 m x 0. 25 mm x 0. 25 mu m) with a carrier gas flow rate of 1 mL/min. Under this condition, the chromatographic peak was sharp and symmetric. An analytical method was developed for the simultaneous determination of the 19 chlorophenol compounds in fish using gas chromatography-mass spectrometry coupled with QuEChERS pretreatment. The improved QuEChERS method was used in sample preparation. The 19 chlorophenol compounds were extracted with organic solvents and purified with purifying agents. During the experiment, the effect of the kinds and volumes of the extraction solvent, as well as the types and dosages of the purifying agent, on the recoveries of the 19 chlorophenol compounds were investigated. Moreover, the temperature and time of derivatization, as well as the dosage of the derivatization agent, were optimized. All aforementioned analyses were conducted with the aim of determining the optimal pretreatment method. Finally, the optimized gas chromatography-mass spectrometry conditions were employed for the quantitative determination of 19 chlorophenol compounds in fish samples. Based on the experimental results, the best extraction method was determined to be the one where the extraction agent (10 mL ethyl acetate) was added to 3 g sodium chloride and 5 g anhydrous magnesium sulfate in the test tube, followed by ultrasonication for 15 min. The sample was centrifuged at 4 500 r/min for 5 min, and 500 mg C-18 was selected as the purifying agent to purify the supernatant. The purified supernatant was blown with nitrogen to less than 1 mL at 45 degrees C, and then redissolved with ethyl acetate to 1 mL. Subsequently, the sample solution was passed through a 0. 22 mu m organic filter membrane, following which 50 mu L bis (trimethylsilyl) trifluoroacetamide was added for derivatization at 45 degrees C for 30 min. Lastly, the 19 chlorophenol compounds were determined by gas chromatography-mass spectrometry with an electrospray ionization source and selecting ion monitoring mode. The 19 chlorophenol compounds were then quantitatively analyzed by the external standard method. The compounds showed good linearity in the concentration range of 0. 4-10 mu g/L, with correlation coefficients (R-2) greater than 0. 998. The limits of detection and limits of quantification were 0. 01-0. 05 mu g/kg and 0. 04-0. 16 mu g/kg, respectively. Moreover, the average recoveries of the 19 chlorophenol compounds were in the range of 70. 6%-115. 0% at three spiked levels, and the relative standard deviations were in the range of 2. 6%-10. 5%. The established method in this study was applied to detect and analyze chlorophenol compounds in actual samples. The experimental results showed that various levels of chlorophenol compounds could be detected in different fishes. Among them, the total amount of chlorophenol compounds detected in the Corvina was 8. 74 mu g/kg, followed by the Crucian carp at 7. 59 mu g/kg, and the minimum detected amount in rice fish (1. 59 mu g/kg). With its simple operation, high sensitivity, and good repeatability, the established method simplifies the pre-treatment of fish samples. It can also meet the requirements for the high-throughput detection of 19 chlorophenol compounds in fish, thereby significantly improving the detection efficiency of chlorophenols. Moreover, the method provides crucial technical support and a theoretical basis for the establishment of feasible detection standards for chlorophenols in China, as well as for the control of residue levels of chlorophenol compounds in fish. The findings have important practical significance to implement management measures during fish breeding and transportation.

24 June 2025 in International Journal of Food Microbiology
Verified
Journal Article
Closed access
SYShuang Yu
Shuang Yu
QCQin Chen
Qin Chen
SMSivakumar Manickam
Sivakumar Manickam
YLYuxun Li
Yuxun Li
MZMengyao Zhang
Mengyao Zhang
YLYanan Liu
Yanan Liu

11 January 2024 in Journal of Chromatography B
Verified
Journal Article
Closed access
YLYu Liu
Yu Liu
JXJiali Xing
Jiali Xing
XBXiaoli Bi
Xiaoli Bi
JSJian Shen
Jian Shen
SZShufen Zhang
Shufen Zhang
YMYinghua Mu
Yinghua Mu

29 July 2025 in Journal of Food Composition and Analysis
Verified
Journal Article
Closed access
QWQingde Wen
Qingde Wen
JXJiali Xing
Jiali Xing
XLXiaohu Luo
Xiaohu Luo
XXXiaorong Xu
Xiaorong Xu
JSJian Shen
Jian Shen
LMLingyan Mao
Lingyan Mao