Ane Francyne Costa

Ms. Ane Francyne Costa

orcid

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 December 2020 in Diagnostic Cytopathology
Verified
Journal Article
Closed access
PDF file
ACAne Francyne Costa
Ane Francyne Costa
MRMariana Goveia Melo Ribeiro
Mariana Goveia Melo Ribeiro
AOAlexandre Sherlley Casimiro Onofre
Alexandre Sherlley Casimiro Onofre
FOFabiana Botelho de Miranda Onofre
Fabiana Botelho de Miranda Onofre

20 November 2020 in Cytopathology
Verified
Journal Article
Closed access
PDF file
ACAne Francyne Costa
Ane Francyne Costa
APAdriane Pogere
Adriane Pogere
APAna Paula Beltrame Farina Pasinato
Ana Paula Beltrame Farina Pasinato
EBEdson Jose Monteiro Bello
Edson Jose Monteiro Bello
AOAlexandre Sherlley Casimiro Onofre
Alexandre Sherlley Casimiro Onofre
FOFabiana Botelho de Miranda Onofre
Fabiana Botelho de Miranda Onofre

7 April 2022 in Cytopathology
Verified
Journal Article
Closed access
ACAne Francyne Costa
Ane Francyne Costa
APAdriane Pogere
Adriane Pogere
APAna Paula Beltrame Farina Pasinato
Ana Paula Beltrame Farina Pasinato
AOAlexandre Sherlley Casimiro Onofre
Alexandre Sherlley Casimiro Onofre
FOFabiana Botelho de Miranda Onofre
Fabiana Botelho de Miranda Onofre

1 January 2024 in JBRA Assisted Reproduction
Verified
Journal Article
Open access
ACAne Francyne Costa
Ane Francyne Costa
FOFabiana Botelho de Miranda Onofre
Fabiana Botelho de Miranda Onofre
AOAlexandre Sherlley Casimiro Onofre
Alexandre Sherlley Casimiro Onofre
Objective: The Neubauer hemocytometer, as well as the Makler chamber, are devices commonly used in andrology laboratories. The present study aimed to verify if both methods yield comparable results, and whether they can be used interchangeably to determine sperm concentration. Methods: Sperm and latex beads concentration measurements were performed with the Neubauer hemocytometer and the Makler chamber. Fixed and proportional biases were estimated, and the method agreement was determined by assessing sperm concentration results with the Bland and Altman plot. The Coefficient of Variation (CV) and relative bias were calculated as an index of precision and accuracy, respectively, by measuring latex beads target concentrations in both chambers. Results: The Makler chamber systematically overestimated the Neubauer hemocytometer concentration measurements by a mean of -7.99%, with limits of agreement (LOA) between -41% to 25.61% (p<0.001). The fixed bias was found for concentration values inferior to 40 x 106/ml range (p0.05). Measurements with the Neubauer hemocytometer showed the greatest consistency in the study with the CV ranging from 3.01% to 6.67%; while the CV with the Makler chamber ranged from 8.46% to 25.64%. The relative bias for the Neubauer hemocytometer determinations varied from 0.12% to 8.40%, while for the Makler chamber varied from 7.6% to an overestimation of 38.0%. Conclusions: Measurements made with the Makler chamber demonstrated more variability and a higher degree of overestimation. The Makler chamber is a poor of oligozoospermic samples, although both chambers render similar results for highly concentrated samples.

23 October 2023 in Cytopathology
Verified
Journal Article
Closed access
APAdriane Pogere
Adriane Pogere
ACAne Francyne Costa
Ane Francyne Costa
APAna Paula Beltrame Farina Pasinato
Ana Paula Beltrame Farina Pasinato
MMMarcos José Machado
Marcos José Machado
FOFabiana Botelho de Miranda Onofre
Fabiana Botelho de Miranda Onofre
AOAlexandre Sherlley Casimiro Onofre
Alexandre Sherlley Casimiro Onofre