Edvaldo Maciel

Mr. Edvaldo Maciel

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 February 2020 in Molecules
Verified
Journal Article
Open access
PDF file
EMEdvaldo Maciel
Edvaldo Maciel
ATAna Lúcia de Toffoli
Ana Lúcia de Toffoli
JAJussara da Silva Alves
Jussara da Silva Alves
FLFernando M. Lancas
Fernando M. Lancas
Human mental disorders can be currently classified as one of the most relevant health topics. Including in this are depression and anxiety, which can affect us at any stage of life, causing economic and social problems. The treatments involve cognitive psychotherapy, and mainly the oral intake of pharmaceutical antidepressants. Therefore, the development of analytical methods for monitoring the levels of these drugs in biological fluids is critical. Considering the current demand for sensitive and automated analytical methods, the coupling between liquid chromatography and mass spectrometry, combined with suitable sample preparation, becomes a useful way to improve the analytical results even more. Herein we present an automated multidimensional method based on high-performance liquid chromatography-tandem mass spectrometry using a lab-made, graphene-based capillary extraction column connected to a C8 analytical column to determined five pharmaceutical drugs in urine. A method enhancement was performed by considering the chromatographic separation and the variables of the loading phase, loading time, loading flow, and injection volume. Under optimized conditions, the study reports good linearity with R2 > 0.98, and limits of detection in the range of 0.5–20 µg L−1. Afterward, the method was applied to the direct analysis of ten untreated urine samples, reporting traces of citalopram in one of them. The results suggest that the proposed approach could be a promising alternative that provides direct and fully automated analysis of pharmaceutical drugs in complex biological matrices.

15 June 2020 in Molecules
Verified
Journal Article
Open access
PDF file
EMEdvaldo Maciel
Edvaldo Maciel
KMKaren Mejía-Carmona
Karen Mejía-Carmona
FLFernando M. Lancas
Fernando M. Lancas
Mycotoxins are secondary metabolites of fungi species widely known for their potentially toxic effects on human health. Considering their frequent presence in crops and their processed food, monitoring them on food-based matrices is now an important topic. Within such a context, the sample preparation step is usually mandatory before the chromatographic analysis, due to the complexity of matrices such as nuts, cereals, beverages, and others. For these reasons, we herein present the evaluation of two greener setups, based on the automation and miniaturization of the sample preparation step for mycotoxin analysis in different beverages. Firstly, we describe an analytical method based on a multidimensional assembly, coupling a lab-made microextraction column (508 µm i.d. × 100 mm) to a UPLC–MS/MS for the analysis of ochratoxin A in beverages. This configuration used a synthesized sorbent phase containing C18-functionalized graphene–silica particles, which exhibited excellent extraction performance, as well as being reusable and cheaper than commercially available extractive phases. Sequentially, a second setup, based on a multidimensional capillary LC coupled to MS/MS, was assessed for the same purpose. In this case, a graphene oxide-based capillary extraction column (254 µm i.d. × 200 mm) was used as the first dimension, while a C18 analytical capillary column performed the mycotoxin separation in beverages. Although this second one has similarities with the first, we focused mainly on the benefits related to the link between a miniaturized/automated sample preparation device with a capillary LC–MS/MS system, which made our analysis greener. Additionally, the chromatographic efficiency could even be enhanced.

10 December 2022 in Analytica Chimica Acta
Verified
Journal Article
Closed access
EMEdvaldo Maciel
Edvaldo Maciel
JBJoão V.B. Borsatto
João V.B. Borsatto
KMKaren Mejia-Carmona
Karen Mejia-Carmona
FLFernando M. Lanças
Fernando M. Lanças

1 March 2025 in Talanta
Verified
Journal Article
Open access
EMEdvaldo Maciel
Edvaldo Maciel
THTanja Habeck
Tanja Habeck
CMChristian Meyners
Christian Meyners
FLFrederik Lermyte
Frederik Lermyte
Native MS (nMS) is a key structural biology technique that makes it possible to study intact proteins and their interactions. Unfortunately, non-volatile salts are incompatible with nMS, which demands a laborious desalting procedure. Non-denaturing size-exclusion chromatography (SEC) allows both rapid desalting and separation and has previously been explored for nMS automation. However, SEC at conventional scale requires rather large sample amounts as well as harsh ESI conditions, which can cause protein unfolding. Capillary LC allows softer conditions; however, the few commercially available SEC columns appropriate for this flow rate are prohibitively expensive for many laboratories. Existing protocols for packing buffer exchange columns rely on specialized equipment and/or result in columns that have limited capacity for size-based protein separation. Here, we present self-packed miniaturized SEC columns with different stationary phases and customizable dimensions. The columns, produced via slurry packing with an ordinary LC pump were used across a range of samples in several applications including nMS, top-down MS (TDMS), ligand screening, and ion mobility (IM)-MS. Native separation allowed acquisition of data from samples containing more than one protein. We acquired native TDMS data of 3 proteins in 12 min, with up to 47 % sequence coverage. IM-MS of alpha-synuclein at different charge states was measured in ca. 60 min (including calibrants), with results that match the literature. Finally, we used SEC-nMS to rapidly screen proteolysis-targeting chimera candidates and performed collision-induced unfolding (CIU) of a PROTAC-induced ternary complex. Through this work, we highlight the potential of SEC to support developments in structural MS.

7 January 2023 in Foods
Verified
Journal Article
Open access
PDF file
JBJoão Victor Basolli Borsatto
João Victor Basolli Borsatto
EMEdvaldo Maciel
Edvaldo Maciel
Alejandro CifuentesAlejandro Cifuentes
Alejandro Cifuentes
FLFernando M. Lancas
Fernando M. Lancas
Sample preparation is usually a complex and time-consuming procedure, which can directly affect the quality of the analysis. Recent efforts have been made to establish analytical methods involving minimal sample preparation, automatized and performed online with the analytical techniques. Online Extraction coupled with Liquid Chromatography–Mass Spectrometry (OLE–LC–MS) allows a fully connected extraction, separation, and analysis system. In this work, the lecithin profile was investigated in commercial sunflower, almonds, peanuts, and pistachio seeds to demonstrate that the concept of extraction, followed by the online analysis of the extract, could be applied to analyze this class of analytes in such complex solid matrices without a prior off-line solvent extraction step. The extraction phase gradient method was optimized. Two different analytical columns were explored, one being a conventional C18 (50 × 2.1 mm, 1.7 µm SPP) and the other a novel self-packed SIGO-C18ec (100 × 0.5, 5 µm FPP), which resulted in better separation. The analysis repeatability was investigated, and suggestions to improve it were pointed out. A characteristic ion with a m/z of 184, related to lysophosphatidylcholine structure, was used to identify the lecithin compounds. The temperature effect on the chromatograms was also explored. In short, it was found that the OLE–LC–MS approach is suitable for the analysis of lecithin compounds in seeds, being a promising alternative for lipidomics approaches in the near future.

24 April 2023 in Proteomics
Verified
Journal Article
Open access
THTanja Habeck
Tanja Habeck
EMEdvaldo Maciel
Edvaldo Maciel
KKKevin Kretschmer
Kevin Kretschmer
FLFrederik Lermyte
Frederik Lermyte
In recent years, top‐down mass spectrometry has become a widely used approach to study proteoforms; however, improving sequence coverage remains an important goal. Here, two different proteins, α‐synuclein and bovine carbonic anhydrase, were subjected to top‐down collision‐induced dissociation (CID) after electrospray ionisation. Two high‐boiling solvents, DMSO and propylene carbonate, were added to the protein solution in low concentration (2%) and the effects on the top‐down fragmentation patterns of the proteins were systematically investigated. Each sample was measured in triplicate, which revealed highly reproducible differences in the top‐down CID fragmentation patterns in the presence of a solution additive, even if the same precursor charge state was isolated in the quadrupole of the instrument. Further investigation supports the solution condition‐dependent selective formation of different protonation site isomers as the underlying cause of these differences. Higher sequence coverage was often observed in the presence of additives, and the benefits of this approach became even more evident when datasets from different solution conditions were combined, as increases up to 35% in cleavage coverage were obtained. Overall, this approach therefore represents a promising opportunity to increase top‐down fragmentation efficiency.