Reordenamiento vehicular y contaminación ambiental por material particulado (2,5 y 10), dióxido de azufre y dióxido de nitrógeno en Lima Metropolitana, Perú
Background: The anemia prevalence is higher in highlands populations. It is assumed that iron deficiency anemia (IDA) in children is mainly due to low dietary intake. However, other suggest that high prevalence of anemia is due to an inappropriate hemoglobin (Hb) adjustment for altitude. Materials and methods: Cross-sectional study conducted in 338 preschoolers (PSC) from Puno-Peru. Hb was measured in whole blood, and ferritin, Soluble transferrin receptor, and Interleukin 6 in serum.The dietary iron intake was assessed by 24-h dietary recall, using NutriCap Software. Hb concentration was assessed as adjusted or unadjusted for altitude. Results: With unadjusted Hb, the anemia prevalence was 4.7%, whereas after Hb correction, the prevalence raised-up to 65.6% (p < 0.001). Reciprocally, erythrocytosis proportion decreased from 20.35 to 0.30% (p < 0.001). Total Body Iron (TBI) showed that 7.44% had ID and 0.32% had IDA. PSC with normal unadjusted Hb levels have more protein and micronutrients intake than anemic ones. PSC with erythrocytosis consumed less fat, and more niacin and ascorbic acid than anemics. Total iron intake was lower in anemic than the other groups, but without statistical significance due to the standard deviation of the data in a small number of anemic PSC (n = 16). TBI, unadjusted Hb, and adjusted Hb were not different between groups consuming or not multimicronutrients. Conclusions: The consumption of iron and iron status in children who live at high altitude is adequate, and that anemia could be due to other micronutrient deficiencies and/or that the adjustment of Hb by altitude is inappropriate.
We evaluated the available literature on the diagnostic performance of hemoglobin (Hb) in the diagnosis of iron deficiency anemia (IDA) in high-altitude populations. We searched PubMed, Web of Science, Scopus, Embase, Medline by Ovid, the Cochrane Library, and LILCAS until 3 May 2022. We included studies that evaluated the diagnostic performance (sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), receiver operating characteristic (ROC) curves, and accuracy) of Hb (with and without an altitude correction factor) compared to any iron deficiency (ID) marker (e.g., ferritin, soluble transferrin receptor (sTFR), transferrin saturation, or total body iron (TBI)) in populations residing at altitudes (≥1000 m above sea level). We identified a total of 14 studies (with 4522 participants). We found disagreement in diagnostic performance test values between the studies, both in those comparing hemoglobin with and in those comparing hemoglobin without a correction factor for altitude. Sensitivity ranged from 7% to 100%, whereas specificity ranged from 30% to 100%. Three studies reported higher accuracy of uncorrected versus altitude-corrected hemoglobin. Similarly, two studies found that not correcting hemoglobin for altitude improved the receiver operating characteristic (ROC) curves for the diagnosis of iron deficiency anemia. Available studies on high-altitude populations suggest that the diagnostic accuracy of Hb is higher when altitude correction is not used. In addition, the high prevalence of anemia in altitude regions could be due to diagnostic misclassification.