Energy harvesting generators are attractive as inexhaustible replacements for batteries in low-power wireless electronic devices and have received increasing research interest in recent years. Ambient motion is one of the main sources of energy for harvesting, and a wide range of motion-powered energy harvesters have been proposed or demonstrated, particularly at the microscale. This paper reviews the principles and state-of-art in motion-driven miniature energy harvesters and discusses trends, suitable applications, and possible future developments.
16 February 2022 in IEEE Transactions on Power Systems
Power electronic converters for integrating renewable energy resources into power systems can be divided into grid-forming and grid-following inverters. They possess certain similarities, but several important differences, which means that the relationship between them is quite subtle and sometimes obscure. In this article, a new perspective based on duality is proposed to create new insights. It successfully unifies the grid interfacing and synchronization characteristics of the two inverter types in a symmetric, elegant, and technology-neutral form. Analysis shows that the grid-forming and grid-following inverters are duals of each other in several ways including a) synchronization controllers: frequency droop control and phase-locked loop (PLL); b) grid-interfacing characteristics: current-following voltage-forming and voltage-following current-forming; c) swing characteristics: current-angle swing and voltage-angle swing; d) inner-loop controllers: output impedance shaping and output admittance shaping; and e) grid strength compatibility: strong-grid instability and weak-grid instability. The swing equations are also derived in dual form, which reveal the dynamic interaction between the grid strength, the synchronization controllers, and the inner-loop controllers. Insights are generated into cases of poor stability in both small-signal and transient/large-signal. The theoretical analysis and simulation results are used to illustrate cases for single-inverter systems, two-inverter systems, and multi-inverter networks.
30 September 2008 in IEEE Transactions on Power Electronics
This paper presents an energy management system (EMS) for a stand-alone droop-controlled microgrid, which adjusts generators output power to minimize fuel consumption and also ensures stable operation. It has previously been shown that frequency-droop gains have a significant effect on stability in such microgrids. Relationship between these parameters and stability margins are therefore identified, using qualitative analysis and small-signal techniques. This allows them to be selected to ensure stability. Optimized generator outputs are then implemented in real-time by the EMS, through adjustments to droop characteristics within this constraint. Experimental results from a laboratory-sized microgrid confirm the EMS function.
7 June 2004 in Journal of Microelectromechanical Systems
Several forms of vibration-driven MEMS microgenerator are possible and are reported in the literature, with potential application areas including distributed sensing and ubiquitous computing. This paper sets out an analytical basis for their design and comparison, verified against full time-domain simulations. Most reported microgenerators are classified as either velocity-damped resonant generators (VDRGs) or Coulomb-damped resonant generators (CDRGs) and a unified analytical structure is provided for these generator types. Reported generators are shown to have operated at well below achievable power densities and design guides are given for optimising future devices. The paper also describes a new class-the Coulomb-force parametric generator (CFPG)-which does not operate in a resonant manner. For all three generators, expressions and graphs are provided showing the dependence of output power on key operating parameters. The optimization also considers physical generator constraints such as voltage limitation or maximum or minimum damping ratios. The sensitivity of each generator architecture to the source vibration frequency is analyzed and this shows that the CFPG can be better suited than the resonant generators to applications where the source frequency is likely to vary. It is demonstrated that mechanical resonance is particularly useful when the vibration source amplitude is small compared to the allowable mass-to-frame displacement. The CDRG and the VDRG generate the same power at resonance but give better performance below and above resonance respectively. Both resonant generator types are unable to operate when the allowable mass frame displacement is small compared to the vibration source amplitude, as is likely to be the case in some MEMS applications. The CFPG is, therefore, required for such applications.
1 September 2004 in Sensors and Actuators A: Physical
Inverter-based resources (IBRs) possess dynamics that are significantly different from those of synchronous-generator-based sources and as IBR penetrations grow the dynamics of power systems are changing. This article discusses the characteristics of the new dynamics and examines how they can be accommodated into the long-standing categorizations of power system stability in terms of angle, frequency, and voltage stability. It is argued that inverters are causing the frequency range over which angle, frequency, and voltage dynamics act to extend such that the previously partitioned categories are now coupled and further coupled to new electromagnetic modes. While grid-forming (GFM) inverters share many characteristics with generators, grid-following (GFL) inverters are different. This is explored in terms of similarities and differences in synchronization, inertia, and voltage control. The concept of duality is used to unify the synchronization principles of GFM and GFL inverters and, thus, established the generalized angle dynamics. This enables the analytical study of GFM-GFL interaction, which is particularly important to guide the placement of GFM apparatuses and is even more important if GFM inverters are allowed to fall back to the GFL mode during faults to avoid oversizing to support short-term overload. Both GFL and GFM inverters contribute to voltage strength but with marked differences, which implies new features of voltage stability. Several directions for further research are identified, including: 1) extensions of nonlinear stability analysis to accommodate new inverter behaviors with cross-coupled time frames; 2) establishment of spatial–temporal indices of system strength and stability margin to guide the provision of new stability services; and 3) data-driven approaches to combat increased system complexity and confidentiality of inverter models.