Kazuhiko Ogimoto

Prof. Kazuhiko Ogimoto

Institute of Industrial Science, The University of Tokyo

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 May 2019 in Energies
Verified
Journal Article
Open access
PDF file
YIYumiko Iwafune
Yumiko Iwafune
KOKazuhiko Ogimoto
Kazuhiko Ogimoto
HAHitoshi Azuma
Hitoshi Azuma
We propose a model for the integration of electric vehicles (EVs) into the grid power system in Japan. The potential of the switchover from conventional vehicles to EVs and the incurred charging loads for the EV fleet were evaluated based on the results of a Japanese road traffic census. Furthermore, an EV battery operation model was incorporated into the production cost analysis model, which is capable of determining the optimal electricity supply and demand, considering the existing interconnector power flows. The potential economic and environmental contributions of EV charge and discharge controls, with the ultimate goal of realizing the introduction of a massive renewable energy source in the future, were also evaluated. We found that EVs can greatly contribute to expanding the use of renewable energy and reducing system cost by charging and discharging not only at the owner’s home but also at his/her workplace.

15 November 2019 in World Electric Vehicle Journal
Verified
Journal Article
Open access
PDF file
RKRyosuke Kataoka
Ryosuke Kataoka
ASAKIRA SHICHI
AKIRA SHICHI
HYHiroyuki Yamada
Hiroyuki Yamada
YIYumiko Iwafune
Yumiko Iwafune
KOKazuhiko Ogimoto
Kazuhiko Ogimoto
The use of batteries of electric vehicles (EVs) for home electricity applications using a bidirectional charger, a process called vehicle-to-home (V2H), is attracting the attention of EV owners as a valuable additional benefit of EVs. To motivate owners to invest in V2H, a quantitative evaluation to compare the performance of EV batteries with that of residential stationary batteries (SBs) is required. In this study, we developed a multi-objective optimization method for the household of EV owners using energy costs including investment and CO2 emissions as indices and compared the performances of V2H and SB. As a case study, a typical detached house in Japan was assumed, and we evaluated the economic and environmental aspects of solar power self-consumption using V2H or SB. The results showed that non-commuting EV owners should invest in V2H if the investment cost of a bidirectional charger is one third of the current cost as compared with inexpensive SB, in 2030. In contrast, our results showed that there were no advantages for commuting EV owners. The results of this study contribute to the rational setting of investment costs to increase the use of V2H by EV owners.

4 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
YIYumiko Iwafune
Yumiko Iwafune
KOKazuhiko Ogimoto
Kazuhiko Ogimoto
The increase in the number of electric vehicles (EVs) has led to increased global expectations that the application of this technology may result in the reduction of CO2 emissions through the replacement of conventional petrol vehicles and ensure the flexibility of power systems such as batteries. In this paper, we propose a residential demand response (DR) evaluation model that considers the degradation mechanism of the EV battery and examines the effective battery operation. We adopted the already-proposed NiMnCo battery degradation model to develop an EV DR evaluation model. In this model, the battery operation is optimized to minimize the electricity and degradation costs affected by ambient temperature, battery state of charge (SOC), and depth of discharge. In this study, we evaluated the impact of the relevant parameters on the economics of the DR of EV batteries for 10 all-electric detached houses with photovoltaic system assuming multiple EV driving patterns and battery (dis)charging constraints. The results indicated that the degradation costs are greatly affected by the SOC condition. If a low SOC can be managed with a DR strategy, the total cost can be reduced. This is because the sum of the reduction of purchased cost from the utility and calendar degradation costs are higher than the increase of the cycle degradation cost. In addition, an analysis was conducted considering different driving patterns. The results showed that the cost reduction was highest when a driving pattern was employed in which the mileage was low and the staying at home time was large. When degradation costs are included, the value of optimized charging and discharging operations is more apparent than when degradation costs are not considered.

12 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
RKRyosuke Kataoka
Ryosuke Kataoka
KOKazuhiko Ogimoto
Kazuhiko Ogimoto
YIYumiko Iwafune
Yumiko Iwafune
Regulating the frequencies of power grids by controlling electric vehicle charging and discharging, known as vehicle-to-grid (V2G) ancillary services, is a promising and profitable means of providing flexibility that integrates variable renewable energy (VRE) into traditional power systems. However, the ancillary services market is a niche, and the scale, saturation, and time-dependency are unclear when assuming future changes in the power system structure. We studied the marginal value of V2G ancillary services as a balancing capacity of the power system operation on the load-frequency control (LFC) timescale and evaluated the reasonable maximum capacity of the LFC provided by V2G. As a case study, we assumed that the Japanese power system would be used under various VRE penetration scenarios and considered the limited availability time of V2G, based on the daily commuter cycle. The power system operation was modeled by considering pumped storage, interconnection lines, and thermal power–partial load operations. The results show that the marginal value of V2G was greater during the daytime than overnight, and the maximum cost saving (USD 705.6/EV/year) occurred during the daytime under the high-VRE scenario. Improving the value and size of V2G ancillary services required coordination with energy storage and excess VRE generation.


27 March 2021 in Energies
Verified
Journal Article
Open access
PDF file
CUChiyori Urabe
Chiyori Urabe
TSTetsuo Saitou
Tetsuo Saitou
KKKazuto Kataoka
Kazuto Kataoka
Takashi IkegamiTakashi Ikegami
Takashi Ikegami
KOKazuhiko Ogimoto
Kazuhiko Ogimoto
Wind power has been increasingly deployed in the last decade to decarbonize the electricity sector. Wind power output changes intermittently depending on weather conditions. In electrical power systems with high shares of variable renewable energy sources, such as wind power, system operators aim to respond flexibly to fluctuations in output. Here, we investigated very short-term fluctuations, short-term fluctuations (STFs), and long-term fluctuations (LTFs) in wind power output by analyzing historical output data for two northern and one southern balancing areas in Japan. We found a relationship between STFs and the average LTFs. The percentiles of the STFs in each month are approximated by linear functions of the monthly average LTFs. Furthermore, the absolute value of the slope of this function decreases with wind power capacity in the balancing area. The LTFs reflect the trend in wind power output. The results indicate that the flexibility required for power systems can be estimated based on wind power predictions. This finding could facilitate the design of the balancing market in Japan.