Adam Zmysłowski

Dr. Adam Zmysłowski

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2017 in Lipids in Health and Disease
Verified
Journal Article
Open access
PDF file
AZAdam Zmysłowski
Adam Zmysłowski
ASArkadiusz Szterk
Arkadiusz Szterk
Due to the fact that one of the main causes of worldwide deaths are directly related to atherosclerosis, scientists are constantly looking for atherosclerotic factors, in an attempt to reduce prevalence of this disease. The most important known pro-atherosclerotic factors include: elevated levels of LDL, low HDL levels, obesity and overweight, diabetes, family history of coronary heart disease and cigarette smoking. Since finding oxidized forms of cholesterol – oxysterols – in lesion in the arteries, it has also been presumed they possess pro-atherosclerotic properties. The formation of oxysterols in the atherosclerosis lesions, as a result of LDL oxidation due to the inflammatory response of cells to mechanical stress, is confirmed. However, it is still unknown, what exactly oxysterols cause in connection with atherosclerosis, after gaining entry to the human body e.g., with food containing high amounts of cholesterol, after being heated. The in vivo studies should provide data to finally prove or disprove the thesis regarding the pro-atherosclerotic prosperities of oxysterols, yet despite dozens of available in vivo research some studies confirm such properties, other disprove them. In this article we present the current knowledge about the mechanism of formation of atherosclerotic lesions and we summarize available data on in vivo studies, which investigated whether oxysterols have properties to cause the formation and accelerate the progress of the disease. Additionally we will try to discuss why such different results were obtained in all in vivo studies.

1 April 2019 in Clinica Chimica Acta
Verified
Journal Article
Closed access
AZAdam Zmysłowski
Adam Zmysłowski
ASArkadiusz Szterk
Arkadiusz Szterk

13 November 2020 in Molecules
Verified
Journal Article
Open access
PDF file
AZAdam Zmysłowski
Adam Zmysłowski
IKIza Ksiazek
Iza Ksiazek
ASArkadiusz Szterk
Arkadiusz Szterk
A GC–MS/MS method with EI ionization was developed and validated to detect and quantify N-nitrosodimethylamine (NDMA) and seven other nitrosamines in 105 samples of metformin tablets from 13 different manufactures. Good linearity for each compound was demonstrated over the calibration range of 0.5–9.5 ng/mL. The assay for all substances was accurate and precise. NDMA was not detected in the acquired active pharmaceutical ingredient (API); however, NDMA was detected in 64 (85.3%) and 22 (91.7%) of the finished product and prolonged finished product samples, respectively. European Medicines Agency recommends the maximum allowed limit of 0.032 ppm in the metformin products. Hence, 28 finished products and 7 pronged dosage products were found to exceed the acceptable limit of daily intake of NDMA contamination. The implications of our findings for the testing of pharmaceutical products are discussed.

1 March 2018 in Food Chemistry
Verified
Journal Article
Closed access
ASArkadiusz Szterk
Arkadiusz Szterk
AZAdam Zmysłowski
Adam Zmysłowski
KBKatarzyna Bus
Katarzyna Bus

1 March 2018 in Materials Science and Engineering: C
Verified
Journal Article
Closed access
AKAgnieszka Kaminska
Agnieszka Kaminska
Tomasz R. SzymborskiTomasz R. Szymborski
Tomasz R. Szymborski
TJTomasz Jaroch
Tomasz Jaroch
AZAdam Zmysłowski
Adam Zmysłowski
ASArkadiusz Szterk
Arkadiusz Szterk

21 April 2022 in The AAPS Journal
Verified
Journal Article
Open access
PDF file
DKDavid A. Keire
David A. Keire
RBRobert Bream
Robert Bream
UWUwe Wollein
Uwe Wollein
JSJeannette Schmaler-Ripcke
Jeannette Schmaler-Ripcke
ABAnnette Burchardt
Annette Burchardt
MWMichael Wierer
Michael Wierer
Recalls of some batches of metformin have occurred due to the detection of N-nitrosodimethylamine (NDMA) in amounts above the acceptable intake (AI) of 96 ng per day. Prior to the recalls, an international regulatory laboratory network had been monitoring drugs for nitrosamine impurities with each laboratory independently developing and validating multiple analytical procedures to detect and measure nitrosamines in metformin drugs used in their jurisdictions. Here, we provide an overview of the analysis of metformin active pharmaceutical ingredients (APIs) and drug products with 1090 samples (875 finished dosage forms (FDFs) and 215 API samples) tested beginning in November of 2019 through July of 2020. Samples were obtained internationally by a variety of approaches, including purchased, received from firms via information requests or selected by regional regulatory authorities (either at wholesalers or during GMP inspections). Only one nitrosamine (NDMA) was detected and was only present in some batches of metformin products. For API samples, 213 out of 215 lots tested had no measurable level of NDMA. For FDF samples tested, the number of batches with NDMA above the AI amount for patient safety was 17.8% (156/875). Based on these data, although the presence of NDMA was of concern, 82.2% of the samples of metformin drug products tested met quality and safety standards for patients. Regulatory agencies continue to collaborate extensively and work with marketing authorization holders to understand root causes of nitrosamine formation and agree on corrective actions to mitigate the presence of NDMA in future metformin batches. Graphical abstract