Junjuan Zhao

Dr. Junjuan Zhao


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2019 in The Journal of the Acoustical Society of America
Verified
Journal Article
Open access
PDF file
JZJunjuan Zhao
Junjuan Zhao
XLXianhui Li
Xianhui Li
WWWenjiang Wang
Wenjiang Wang
YWYueyue Wang
Yueyue Wang
LZLiying Zhu
Liying Zhu
YLYunan Liu
Yunan Liu
In this letter, a membrane-type acoustic metamaterial with a compact magnet (MAMM) is presented. To investigate its frequency-tunable properties, a theoretical model considering both static and dynamic effects of magnetic force is established. Analytical investigations indicate that tuning of the magnetic force exerted on the centralized rigid iron platelet leads to the shift in the MAMM's transmission loss peaks. The experimental anti-resonance frequencies of the MAMM derived from the impedance tube measurements exhibited good consistency with those predicted theoretically. Continuously tuned in a wide frequency range, this structure can well adapt to the noise source variation in insulation design.

24 August 2011 in Applied Optics
Verified
Journal Article
Closed access
PDF file
JZJunjuan Zhao
Junjuan Zhao
ZZZhan Zhao
Zhan Zhao
LDLi Dong Du
Li Dong Du
SWShaohua Wu
Shaohua Wu
Optics InfoBase is the Optical Society's online library for flagship journals, partnered and copublished journals, and recent proceedings from OSA conferences.

1 April 2011 in Review of Scientific Instruments
Verified
Journal Article
Closed access
JZJunjuan Zhao
Junjuan Zhao
ZZZhan Zhao
Zhan Zhao
LDLi Dong Du
Li Dong Du
DGDaoqu Geng
Daoqu Geng
SWShaohua Wu
Shaohua Wu
A detailed study on a photoacoustic carbon dioxide detection system, through sound card based on virtual instrument, is presented in this paper. In this system, the CO2 concentration was measured with the non-resonant photoacoustic cell technique through measuring the photoacoustic signal caused by the CO2. In order to obtain small photoacoustic signals buried in noise, a measurement software was designed with LABVIEW. It has functions of Lock-in Amplifier, digital filter, and signal generator; can also be used to achieve spectrum analysis and signal recovery; has been provided with powerful function for data processing and communication with other measuring instrument. The test results show that the entire system has an outstanding measuring performance with the sensitivity of 10μv between 10–44 KHz. The non-resonance test of the trace gas analyte CO2 conducted at 100 Hz demonstrated large signals (15.89 mV) for CO2 concentrations at 600 ppm and high signal-to-noise values (∼ 85:1).