Kang-Ho Lee

Dr. Kang-Ho Lee


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
KLKang-Ho Lee
Kang-Ho Lee
YKYeong-Eun Kwon
Yeong-Eun Kwon
HLHyukjin Lee
Hyukjin Lee
YLYongkoo Lee
Yongkoo Lee
JSJoonho Seo
Joonho Seo
DLDongkyu Lee
Dongkyu Lee
A body pressure relief system was newly developed with optical pressure sensors for pressure ulcer prevention. Unlike a conventional alternating pressure air mattress (APAM), this system automatically regulates air flow into a body supporting mattress with adaptive inflation (or deflation) duration in response to the pressure level in order to reduce skin stress due to prolonged high pressures. The system continuously quantifies the body pressure distribution using time-of-flight (ToF) optical sensors. The proposed pressure sensor, a ToF optical sensor in the air-filled cell, measures changes in surface height of mattress when pressed under body weight, thereby indirectly indicating the interface pressure. Non-contact measurement of optical sensor usually improves the durability and repeatability of the system. The pressure sensor was successfully identified the 4 different-predefined postures, and quantitatively measured the body pressure distribution of them. Duty cycle of switches in solenoid valves was adjusted to 0–50% for pressure relief, which shows that the interface pressure was lower than 32 mmHg for pressure ulcer prevention.

8 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
JSJi-Hyeon Seo
Ji-Hyeon Seo
HLHyuk-Jin Lee
Hyuk-Jin Lee
Dong-Wook SeoDong-Wook Seo
Dong-Wook Seo
DLDongkyu Lee
Dongkyu Lee
OKOhwon Kwon
Ohwon Kwon
KLKang-Ho Lee
Kang-Ho Lee
Typically, the actual volume of the residual limb changes over time. This causes the prosthesis to not fit, and then pain and skin disease. In this study, a prosthetic socket was developed to compensate for the volume change of the residual limb. Using an inflatable air bladder, the proposed socket monitors the pressure in the socket and keeps the pressure distribution uniform and constant while walking. The socket has three air bladders on anterior and posterior tibia areas, a latching type 3-way pneumatic valve and a portable control device. In the paper, the mechanical properties of the air bladder were investigated, and the electromagnetic analysis was performed to design the pneumatic valve. The controller is based on a hysteresis control algorithm with a closed loop, which keeps the pressure in the socket close to the initial set point over a long period of time. In experiments, the proposed prosthesis was tested through the gait simulator that can imitate a human’s gait cycle. The active volume compensation of the socket was successfully verified during repetitive gait cycle using the weight loads of 50, 70, and 90 kg and the residual limb model with a variety of volumes. It was confirmed that the pressure of the residual limb recovered to the initial state through the active control. The pressure inside the socket had a steady state error of less than 0.75% even if the volume of the residual limb was changed from −7% to +7%.

7 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
DLDongkyu Lee
Dongkyu Lee
DKDeawook Kim
Deawook Kim
JHJounghyuk Han
Jounghyuk Han
JYJongsu Yun
Jongsu Yun
KLKang-Ho Lee
Kang-Ho Lee
JLJaejong Lee
Jaejong Lee
We developed an integrated PCR system that performs automated sample preparation and fast polymerase chain reaction (PCR) for application in point-of care (POC) testing. This system is assembled from inexpensive 3D-printing parts, off-the-shelf electronics and motors. Molecular detection requires a series of procedures including sample preparation, amplification, and fluorescence intensity analysis. The system can perform automated DNA sample preparation (extraction, separation and purification) in ≤5 min. The variance of the automated sample preparation was clearly lower than that achieved using manual DNA extraction. Fast thermal ramp cycles were generated by a customized thermocycler designed to automatically transport samples between heating and cooling blocks. Despite the large sample volume (50 μL), rapid two-step PCR amplification completed 40 cycles in ≤13.8 min. Variations in fluorescence intensity were measured by analyzing fluorescence images. As proof of concept of this system, we demonstrated the rapid DNA detection of pathogenic bacteria. We also compared the sensitivity of this system with that of a commercial device during the automated extraction and fast PCR of Salmonella bacteria.

26 December 2023 in Sensors
Verified
Journal Article
Open access
PDF file
KLKang-Ho Lee
Kang-Ho Lee
HHHyunseok Heo
Hyunseok Heo
JKJeongmin Kim
Jeongmin Kim
JCJang Hyuk Cho
Jang Hyuk Cho
KKKyoung Tae Kim
Kyoung Tae Kim
YLYongkoo Lee
Yongkoo Lee
Amputees typically experience changes in residual limb volume in their daily lives. It causes an uncomfortable fit of the socket by applying high pressure on the sensitive area of the residual limb or by loosening the socket. In this study, we developed a transfemoral prosthetic socket for above-the-knee amputees that ensures a good socket fit by maintaining uniform and constant contact pressure despite volume changes in the residual limb. The socket has two air bladders in the posterior femoral region, and the pneumatic controller is located on the tibia of the prosthesis. The pneumatic system aims to minimize unstable fitting of the socket and improve walking performance by inflating or deflating the air bladder. The developed socket autonomously maintains the air pressure inside the prosthetic socket at a steady-state error of 3 mmHg or less by adjusting the amount of air in the air bladder via closed-loop control. In the clinical trial, amputee participants walked on flat and inclined surfaces. The displacement between the residual limb and socket during the gait cycle was reduced by up to 33.4% after air injection into the socket. The inflatable bladder increased the knee flexion angle on the affected side, resulting in increased stride length and gait velocity. The pneumatic socket provides a stable and comfortable walking experience not only when walking on flat ground but also on slopes.

14 July 2018 in Sensors
Verified
Journal Article
Open access
PDF file
KLKang-Ho Lee
Kang-Ho Lee
DLDongkyu Lee
Dongkyu Lee
JYJongsu Yoon
Jongsu Yoon
OKOhwon Kwon
Ohwon Kwon
JLJaejong Lee
Jaejong Lee
A disposable potentiometric sensor was newly developed for the amplification-coupled detection of nucleic acids. The hydrogen-ion is generally released during isothermal amplification of nucleic acids. The surface potential on the oxide-functionalized electrode of the extended gate was directly measured using full electrical circuits with the commercial metal-oxide semiconductor field-effect transistors (MOSFETs) and ring oscillator components, which resulted in cost-effective, portable and scalable real-time nucleic acid analysis. The current-starved ring oscillator changes surface potential to its frequency depending on the square of the variation in pH with a high signal-to-noise ratio during isothermal amplification. The device achieves a conversion rate of 20.5 kHz/mV and a detection resolution of 200 µV for the surface potential. It is demonstrated that the sensor successfully monitors in real-time isothermal amplification of the extracted nucleic acids from Salmonella pathogenic bacteria. The in situ variations in the frequency of the pH-sensitive sensor were compared with the results of both a conventional optical device and pH-meter during isothermal amplification.

1 February 2017 in Electronics Letters
Verified
Journal Article
Open access
PDF file
KLKang-Ho Lee
Kang-Ho Lee
DLD. Lee
D. Lee
JYJ. Yoon
J. Yoon
OKO. Kwon
O. Kwon
JLJ. Lee
J. Lee
A pH‐sensitive sensor with a differential mode was developed to detect surface charges accumulated on the ion‐sensitive layer. The device accurately monitors the relative pH value using the modified instrumentation amplifier with the DC electrode‐offset compensation. The readout voltage is digitalised with the current‐starved ring oscillator. The sensor achieves the DC offset compensation of 22.5 dB and the oscillating pH sensitivity of 1.3 MHz/pH. The feasibility of the sensor is demonstrated to monitor the hydrogen ion concentration comparing the oscillation frequency at differential mode with that at single mode.