Kwang-Hwan Choi

Prof. Kwang-Hwan Choi


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 May 2020 in Energies
Verified
Journal Article
Open access
PDF file
HCHwiUng Choi
HwiUng Choi
KCKwang-Hwan Choi
Kwang-Hwan Choi
In the present work, the electrical and thermal performances of a newly designed PV/T (photovoltaic/thermal) air collector, which was proposed and fabricated by the author, have been investigated experimentally in the natural weather conditions. The PV/T air collector has a single-pass double-flow air channel. Also, a non-uniform cross-section transverse rib was attached at the back surface of the PV (photovoltaic) module to improve the heat transfer performance between the PV module and flowing air. The experiment was carried out in an outdoor field on a clear day with various air mass flow rates ranges from 0.0198 kg/s to 0.07698 kg/s. In the results, it was found that the average thermal efficiency of the PV/T collector increased from 35.2% to 56.72% as the air mass flow rate increased. The average electrical efficiency also increased from 14.23% to 14.81% with an increase in an air mass flow rate, but the effect of air mass flow rate on the increase in electrical efficiency was inconsiderable. The average overall efficiency, which represents the sum of electrical and thermal efficiencies, was in the range of 49.44% to 71.54% and it increased as the air mass flow rate increased. The maximum value of average overall efficiency during the test period was found to be 71.54% at an air mass flow rate of 0.07698 kg/s. From the results, it was confirmed that the newly designed PV/T air collector provides a significant enhancement in solar energy utilization.

2 March 2020 in Energies
Verified
Journal Article
Open access
PDF file
HCHwiUng Choi
HwiUng Choi
KCKwang-Hwan Choi
Kwang-Hwan Choi
In this study, a two-dimensional CFD (computational fluid dynamics) analysis was performed to investigate the heat-transfer and fluid-friction characteristics in a solar air heater having a transverse triangular block at the bottom of the air duct. The Reynolds number, block height (e), pitch (P), and length (l) were chosen as design parameters. The results are validated by comparing the Nusselt number predicted by simulation with available experimental results. Renormalization-group (RNG) k - ε model with enhanced wall-treatment was selected as the most appropriate turbulence model. From the results, it was found that the presence of a transverse triangular block produces a higher Nusselt number than that of smooth air duct. The enhancement in Nusselt number varied from 1.19 to 3.37, according to the geometric conditions investigated. However, the use of transverse triangular block also results in significantly higher friction losses. The thermohydraulic performance (THPP) was also estimated and has a maximum value of 1.001 for height (e) of 20 mm, length (l) of 120 mm, and pitch (P) of 150 mm, at Reynolds number of 8000. Furthermore, in the present study, correlations of the Nusselt number and friction factor were developed as a function of geometrical conditions of the transverse triangular block and Reynolds number, which can be used to predict the value of Nusselt number and friction factor with the absolute percentage deviations of 3.29% and 7.92%, respectively.



17 March 2023 in Sustainability
Verified
Journal Article
Open access
PDF file
HCHwiUng Choi
HwiUng Choi
KMKwang-Am Moon
Kwang-Am Moon
SKSeong-Bhin Kim
Seong-Bhin Kim
KCKwang-Hwan Choi
Kwang-Hwan Choi
This study discussed the effect of ribbed fin, which was suggested by the authors, on the enhancement of heat transfer and flow characteristics of fluid in a solar air heater. The ribbed fin has a rectangular rib at the base and side surfaces of the fin. Thus, it can increase the heat transfer coefficient in the fluid field of a solar air heater as well as extend the heat transfer area. The simulation was performed with various Reynolds numbers, relative heights, and pitches of the rib. The presence of the rib enhances the heat transfer performance by 3.497 times over a smooth fin. However, the addition of the rib also increases pressure drop. Thus, the thermo-hydraulic performance, which considers both heat transfer enhancement and pressure drop increase, was also discussed. Furthermore, this study developed correlations for the Nusselt number and friction factor as a function of geometric condition of the rib and Reynolds number. The correlations accurately predicted the Nusselt number for the base and side surfaces of the fin and friction factor with mean absolute percent errors of 4.24%, 4.53%, and 7.33%, respectively.

5 June 2022 in Energies
Verified
Journal Article
Open access
PDF file
HCHwiUng Choi
HwiUng Choi
KCKwang-Hwan Choi
Kwang-Hwan Choi
This study experimentally investigated the performance of a PVT air collector coupled with a triangular block. The triangular block, newly suggested by the authors, is a triangular-shaped obstacle and was inserted at the bottom of the PVT air collector to enhance the heat transfer performance of the collector. The experiment was carried out in actual climate conditions in Korea with two air mass flow rate conditions: 0.03606 kg/m2 s and 0.06948 kg/m2 s. Results show the average values of electrical efficiency of the collector during the test period to be 16.15% and 16.43% for each air mass flow rate, while thermal efficiencies were 28.83% and 38.36%, respectively. The average values of total energy efficiencies were found to be 44.99% and 54.79%, respectively. The results show that air mass flow rate has a large impact on thermal and total energy efficiency, while it has a small impact on electrical efficiency. Furthermore, it was confirmed that the PVT air collector coupled with a triangular block can enhance the utilization of solar energy since the thermal performance was higher than that of the collector without a triangular block.