Saman Sadeghi

Prof. Saman Sadeghi


Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 November 2017 in Micromachines
Verified
Journal Article
Open access
PDF file
NHNoel Ha
Noel Ha
SSSaman Sadeghi
Saman Sadeghi
RDR. Michael Van Dam
R. Michael Van Dam
Radiopharmaceuticals labeled with short-lived positron-emitting or gamma-emitting isotopes are injected into patients just prior to performing positron emission tomography (PET) or single photon emission tomography (SPECT) scans, respectively. These imaging modalities are widely used in clinical care, as well as in the development and evaluation of new therapies in clinical research. Prior to injection, these radiopharmaceuticals (tracers) must undergo quality control (QC) testing to ensure product purity, identity, and safety for human use. Quality tests can be broadly categorized as (i) pharmaceutical tests, needed to ensure molecular identity, physiological compatibility and that no microbiological, pyrogenic, chemical, or particulate contamination is present in the final preparation; and (ii) radioactive tests, needed to ensure proper dosing and that there are no radiochemical and radionuclidic impurities that could interfere with the biodistribution or imaging. Performing the required QC tests is cumbersome and time-consuming, and requires an array of expensive analytical chemistry equipment and significant dedicated lab space. Calibrations, day of use tests, and documentation create an additional burden. Furthermore, in contrast to ordinary pharmaceuticals, each batch of short-lived radiopharmaceuticals must be manufactured and tested within a short period of time to avoid significant losses due to radioactive decay. To meet these challenges, several efforts are underway to develop integrated QC testing instruments that automatically perform and document all of the required tests. More recently, microfluidic quality control systems have been gaining increasing attention due to vastly reduced sample and reagent consumption, shorter analysis times, higher detection sensitivity, increased multiplexing, and reduced instrumentation size. In this review, we describe each of the required QC tests and conventional testing methods, followed by a discussion of efforts to directly miniaturize the test or examples in the literature that could be implemented for miniaturized QC testing.

23 June 2014 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
QHQinggang He
Qinggang He
YWYing Wang
Ying Wang
IAInes Alfeazi
Ines Alfeazi
SSSaman Sadeghi
Saman Sadeghi

2 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
ALArtem Lebedev
Artem Lebedev
JJJing Jiao
Jing Jiao
JLJason Lee
Jason Lee
FYFan Yang
Fan Yang
NANathanael Allison
Nathanael Allison
SSSaman Sadeghi
Saman Sadeghi
New radiochemistry techniques can yield novel PET tracers for COX-2 and address the shortcomings in in vivo stability and specificity, which have held back clinical translation of tracers to image COX-2 expression. Current techniques limit radiosynthesis to analogs of the COX-2 inhibitors with fluorine-18 added via a carbon chain, or on an aromatic position which renders the radiolabeled analog less specific towards COX-2, resulting in tracers with low in vivo stability or specificity. To solve this problem, we have developed a new high affinity, 18F-labelled COX-2 inhibitor that is radiolabeled directly on a heteroaromatic ring. This molecule exhibits favorable biodistribution and increased metabolic stability. Synthesis of this molecule cannot be achieved by traditional means; consequently, we have developed an automated electrochemical radiosynthesis platform to synthesize up to 5 mCi of radiochemically pure 18F-COX-2ib in 4 hours (2% decay-corrected radiochemical yield). In vitro studies demonstrated clear correlation between COX-2 expression and uptake of the tracer. PET imaging of healthy animals confirmed that the molecule is excreted from blood within an hour, mainly through the hepatobiliary excretion pathway. In vivo metabolism data demonstrated that > 95% of the injected radioactivity remains in the form of the parent molecule 1 hour after injection.

14 July 2017 in Journal of the Electrochemical Society
Verified
Journal Article
Open access
PDF file
MBMehrdad Balandeh
Mehrdad Balandeh
CWChristopher Waldmann
Christopher Waldmann
DSDaniela Shirazi
Daniela Shirazi
AGAdrian Gomez
Adrian Gomez
ARAlejandra Rios
Alejandra Rios
SSSaman Sadeghi
Saman Sadeghi
Electrochemical fluorination of methyl(phenylthio)acetate was achieved using tetrabutylammonium fluoride (TBAF). Electrochemical fluorination was performed under potentiostatic anodic oxidation using an undivided cell in acetonitrile containing TBAF and triflic acid. The influence of several parameters including: oxidation potential, time, temperature, sonication, TBAF concentration and triflic acid concentration on fluorination efficiency were studied. It was found that the triflic acid to TBAF concentration ratio plays a key role in the fluorination efficiency. Electrochemical fluorination resulted in formation of mono-fluorinated methyl 2-fluoro-2-(phenylthio)acetate verified by gas chromatography–mass spectrometry (GC-MS) and nuclear magnetic resonance (NMR) Spectroscopy. Under optimum conditions 44 ± 3% mono fluorination yield was obtained after a 30 min electrolysis. Electrochemical radiofluorination for the synthesis of methyl 2-[18F]fluoro-2-(phenothio) acetate was also achieved with the same optimized electrochemical cell parameters where TBAF was first passed through an anion exchange resin containing fluorine-18. A radiochemical fluorination efficiency of 7 ± 1% was achieved after 30 min of electrolysis.

1 September 2017 in Applied Radiation and Isotopes
Verified
Journal Article
Closed access
CWChristopher M. Waldmann
Christopher M. Waldmann
ALArtem Lebedev
Artem Lebedev
NANathaniel Allison
Nathaniel Allison
SSSaman Sadeghi
Saman Sadeghi

30 August 2018 in ChemElectroChem
Verified
Journal Article
Closed access
PDF file
MBMehrdad Balandeh
Mehrdad Balandeh
ARAlejandra Rios
Alejandra Rios
NANathanael Allison
Nathanael Allison
DSDaniela Shirazi
Daniela Shirazi
AGAdrian Gomez
Adrian Gomez
SSSaman Sadeghi
Saman Sadeghi