Wei Xu

Dr. Wei Xu


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2020 in Metals
Verified
Journal Article
Open access
PDF file
WXWei Xu
Wei Xu
YZYanguang Zhao
Yanguang Zhao
XCXin Chen
Xin Chen
BZBin Zhong
Bin Zhong
HYHuichen Yu
Huichen Yu
CTChunhu Tao
Chunhu Tao
This paper proposes an ultra-high frequency (UHF) fatigue test of a titanium alloy TA11 based on electrodynamic shaker in order to develop a feasible testing method in the VHCF regime. Firstly, a type of UHF fatigue specimen is designed to make its actual testing frequency reach as high as 1756 Hz. Then the influences of the loading frequency and loading types on the testing results are considered separately, and a series of comparative fatigue tests are hence conducted. The results show the testing data from the present UHF fatigue specimen agree well with those from the conventional vibration fatigue specimen with the loading frequency of 240 Hz. Furthermore, the present UHF testing data show good consistency with those from the axial-loading fatigue and rotating bending fatigue tests. But the obtained fatigue life from ultrasonic fatigue test with the loading frequency of 20 kHz is significantly higher than all other fatigue test results. Thus the proposed ultra-high frequency vibration-based fatigue test shows a balance of high efficiency and similarity with the conventional testing results.

16 April 2023 in Materials
Verified
Journal Article
Open access
PDF file
YZYue Zhang
Yue Zhang
JHJiangkun Hu
Jiangkun Hu
LKLixia Kang
Lixia Kang
YHYuhuai He
Yuhuai He
WXWei Xu
Wei Xu
The thickness debit effect of creep behavior has been a focal point of nickel-based single-crystal superalloy research, and there is a need for an advanced creep deformation measurement method. This study developed a novel high-temperature creep test system based on a single-camera stereo digital image correlation (DIC) method with four plane mirrors to conduct creep tests on thin-walled specimens of a nickel-based single-crystal alloy, DD6, with thicknesses of 0.6 mm and 1.2 mm under experimental conditions of 980 °C/250 MPa. The reliability of the single-camera stereo DIC method in measuring long-term deformation at a high temperature was experimentally verified. The experimental results show that the creep life of the thinner specimen was significantly shorter. It was found the lack of coordination in the creep deformation process of the edge and middle section of the thin-walled specimens may be an important factor in the thickness debit effect according to the full-field strain contour. By comparing the local strain curve at the rupture point with the average creep strain curve, it was found that the creep rate at the rupture point was less affected by the specimen thickness during the secondary creep stage, while the average creep rate in the working section significantly increased as the wall thickness decreased. The thicker specimen usually had a higher average rupture strain and higher damage tolerance, which prolonged the rupture time.