Jooeun Ahn

Prof. Jooeun Ahn

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 March 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JAJooeun Ahn
Jooeun Ahn
NHNeville Hogan
Neville Hogan
The control architecture underlying human reaching has been established, at least in broad outline. However, despite extensive research, the control architecture underlying human locomotion remains unclear. Some studies show evidence of high-level control focused on lower-limb trajectories; others suggest that nonlinear oscillators such as lower-level rhythmic central pattern generators (CPGs) play a significant role. To resolve this ambiguity, we reasoned that if a nonlinear oscillator contributes to locomotor control, human walking should exhibit dynamic entrainment to periodic mechanical perturbation; entrainment is a distinctive behavior of nonlinear oscillators. Here we present the first behavioral evidence that nonlinear neuro-mechanical oscillators contribute to the production of human walking, albeit weakly. As unimpaired human subjects walked at constant speed, we applied periodic torque pulses to the ankle at periods different from their preferred cadence. The gait period of 18 out of 19 subjects entrained to this mechanical perturbation, converging to match that of the perturbation. Significantly, entrainment occurred only if the perturbation period was close to subjects' preferred walking cadence: it exhibited a narrow basin of entrainment. Further, regardless of the phase within the walking cycle at which perturbation was initiated, subjects' gait synchronized or phase-locked with the mechanical perturbation at a phase of gait where it assisted propulsion. These results were affected neither by auditory feedback nor by a distractor task. However, the convergence to phase-locking was slow. These characteristics indicate that nonlinear neuro-mechanical oscillators make at most a modest contribution to human walking. Our results suggest that human locomotor control is not organized as in reaching to meet a predominantly kinematic specification, but is hierarchically organized with a semi-autonomous peripheral oscillator operating under episodic supervisory control.

12 November 2012 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JAJooeun Ahn
Jooeun Ahn
NHNeville Hogan
Neville Hogan
Theoretical studies and robotic experiments have shown that asymptotically stable periodic walking may emerge from nonlinear limit-cycle oscillators in the neuro-mechanical periphery. We recently reported entrainment of human gait to periodic mechanical perturbations with two essential features: 1) entrainment occurred only when the perturbation period was close to the original (preferred) walking period, and 2) entrainment was always accompanied by phase locking so that the perturbation occurred at the end of the double-stance phase. In this study, we show that a highly-simplified state-determined walking model can reproduce several salient nonlinear limit-cycle behaviors of human walking: 1) periodic gait that is 2) asymptotically stable; 3) entrainment to periodic mechanical perturbations only when the perturbation period is close to the model's unperturbed period; and 4) phase-locking to locate the perturbation at the end of double stance. Importantly, this model requires neither supra-spinal control nor an intrinsic self-sustaining neural oscillator such as a rhythmic central pattern generator. Our results suggest that several prominent limit-cycle features of human walking may stem from simple afferent feedback processes without significant involvement of supra-spinal control or a self-sustaining oscillatory neural network.

23 September 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JAJooeun Ahn
Jooeun Ahn
NHNeville Hogan
Neville Hogan
Stride intervals of normal human walking exhibit long-range temporal correlations. Similar to the fractal-like behaviors observed in brain and heart activity, long-range correlations in walking have commonly been interpreted to result from chaotic dynamics and be a signature of health. Several mathematical models have reproduced this behavior by assuming a dominant role of neural central pattern generators (CPGs) and/or nonlinear biomechanics to evoke chaos. In this study, we show that a simple walking model without a CPG or biomechanics capable of chaos can reproduce long-range correlations. Stride intervals of the model revealed long-range correlations observed in human walking when the model had moderate orbital stability, which enabled the current stride to affect a future stride even after many steps. This provides a clear counterexample to the common hypothesis that a CPG and/or chaotic dynamics is required to explain the long-range correlations in healthy human walking. Instead, our results suggest that the long-range correlation may result from a combination of noise that is ubiquitous in biological systems and orbital stability that is essential in general rhythmic movements.

11 August 2021 in Science Robotics
Verified
Journal Article
Closed access
SYSung-Sik Yun
Sung-Sik Yun
KKKeewon Kim
Keewon Kim
JAJooeun Ahn
Jooeun Ahn
KCkyujin Cho
kyujin Cho
By adding impedance to human joints via a soft and passive exosuit, we changed human motor patterns in intended ways.

23 December 2020 in IEEE Transactions on Medical Robotics and Bionics
Verified
Journal Article
Open access
SCSangheui Cheon
Sangheui Cheon
DKDaekyum Kim
Daekyum Kim
SKSudeok Kim
Sudeok Kim
BKBrian Byunghyun Kang
Brian Byunghyun Kang
JLJongeun Lee
Jongeun Lee
JAJooeun Ahn
Jooeun Ahn
The practical operation of wearable robots requires intuitive, compact, yet reliable control interfaces. However, current myoelectric interfaces based on surface electromyography (EMG) often fail to achieve these requirements by demanding multiple sensors and exhibiting unreliable performance under limb posture changes. In this study, we show that a myoelectric interface on the musculotendinous junctions (MTJs) of the flexor digitorum superficialis (FDS) enables reliable control of a robotic glove with a single EMG sensor by identifying power grasp intentions. We found that the myoelectric signals from the MTJs of the FDS show significantly increased amplitudes exclusively when a power grasp is performed, regardless of the arm posture. We systematically verified that, in identifying power grasp intentions, the proposed single-sensor myoelectric interface even outperforms a five-sensor myoelectric interface around the proximal forearm. By exploiting the unique biological feature of the MTJs, we devised two myoelectric control methods for a robotic glove—Dual-threshold control and Morse-code control—and further showed their performances in practical operations. Dual-threshold control enables direct co-operation between the user and the robotic glove, and Morse-code control provides various command options for the user.

23 March 2015 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JAJooeun Ahn
Jooeun Ahn
NHNeville Hogan
Neville Hogan
Mathematical techniques have provided tools to quantify the stability of rhythmic movements of humans and machines as well as mathematical models. One archetypal example is the use of Floquet multipliers: assuming periodic motion to be a limit-cycle of a nonlinear oscillator, local stability has been assessed by evaluating the rate of convergence to the limit-cycle. However, the accuracy of the assessment in experiments is questionable: Floquet multipliers provide a measure of orbital stability for deterministic systems, but various components of biological systems and machines involve inevitable noise. In this study, we show that the conventional estimate of orbital stability, which depends on regression, has bias in the presence of noise. We quantify the bias, and devise a new method to estimate orbital stability more accurately. Compared with previous methods, our method substantially reduces the bias, providing acceptable estimates of orbital stability with an order-of-magnitude fewer cycles.