Jili Chen

Jili Chen


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 August 2019 in Eye
Verified
Journal Article
Closed access
PDF file
JHJie He
Jie He
TCTingyi Cao
Tingyi Cao
FXFeiping Xu
Feiping Xu
SWShasha Wang
Shasha Wang
HTHaiqi Tao
Haiqi Tao
JCJili Chen
Jili Chen

6 March 2023 in British Journal of Ophthalmology
Verified
Journal Article
Open access
CGChufeng Gu
Chufeng Gu
YWYujie Wang
Yujie Wang
YJYan Jiang
Yan Jiang
FXFeiping Xu
Feiping Xu
SWShasha Wang
Shasha Wang
JCJili Chen
Jili Chen
Background/aims: This study evaluates the performance of the Airdoc retinal artificial intelligence system (ARAS) for detecting multiple fundus diseases in real-world scenarios in primary healthcare settings and investigates the fundus disease spectrum based on ARAS.Methods: This real-world, multicentre, cross-sectional study was conducted in Shanghai and Xinjiang, China. Six primary healthcare settings were included in this study. Colour fundus photographs were taken and graded by ARAS and retinal specialists. The performance of ARAS is described by its accuracy, sensitivity, specificity and positive and negative predictive values. The spectrum of fundus diseases in primary healthcare settings has also been investigated.Results: A total of 4795 participants were included. The median age was 57.0 (IQR 39.0–66.0) years, and 3175 (66.2%) participants were female. The accuracy, specificity and negative predictive value of ARAS for detecting normal fundus and 14 retinal abnormalities were high, whereas the sensitivity and positive predictive value varied in detecting different abnormalities. The proportion of retinal drusen, pathological myopia and glaucomatous optic neuropathy was significantly higher in Shanghai than in Xinjiang. Moreover, the percentages of referable diabetic retinopathy, retinal vein occlusion and macular oedema in middle-aged and elderly people in Xinjiang were significantly higher than in Shanghai.Conclusion: This study demonstrated the dependability of ARAS for detecting multiple retinal diseases in primary healthcare settings. Implementing the AI-assisted fundus disease screening system in primary healthcare settings might be beneficial in reducing regional disparities in medical resources. However, the ARAS algorithm must be improved to achieve better performance.Trial registration number: NCT04592068.

20 July 2022 in BioMedical Engineering OnLine
Verified
Journal Article
Open access
PDF file
RLRui Liu
Rui Liu
QLQingchen Li
Qingchen Li
FXFeiping Xu
Feiping Xu
SWShasha Wang
Shasha Wang
JHJie He
Jie He
JCJili Chen
Jili Chen
Background: To assess the feasibility and clinical utility of artificial intelligence (AI)-based screening for diabetic retinopathy (DR) and macular edema (ME) by combining fundus photos and optical coherence tomography (OCT) images in a community hospital. Methods: Fundus photos and OCT images were taken for 600 diabetic patients in a community hospital. Ophthalmologists graded these fundus photos according to the International Clinical Diabetic Retinopathy (ICDR) Severity Scale as the ground truth. Two existing trained AI models were used to automatically classify the fundus images into DR grades according to ICDR, and to detect concomitant ME from OCT images, respectively. The criteria for referral were DR grades 2–4 and/or the presence of ME. The sensitivity and specificity of AI grading were evaluated. The number of referable DR cases confirmed by ophthalmologists and AI was calculated, respectively. Results: DR was detected in 81 (13.5%) participants by ophthalmologists and in 94 (15.6%) by AI, and 45 (7.5%) and 53 (8.8%) participants were diagnosed with referable DR by ophthalmologists and by AI, respectively. The sensitivity, specificity and area under the curve (AUC) of AI for detecting DR were 91.67%, 96.92% and 0.944, respectively. For detecting referable DR, the sensitivity, specificity and AUC of AI were 97.78%, 98.38% and 0.981, respectively. ME was detected from OCT images in 49 (8.2%) participants by ophthalmologists and in 57 (9.5%) by AI, and the sensitivity, specificity and AUC of AI were 91.30%, 97.46% and 0.944, respectively. When combining fundus photos and OCT images, the number of referrals identified by ophthalmologists increased from 45 to 75 and from 53 to 85 by AI. Conclusion: AI-based DR screening has high sensitivity and specificity and may feasibly improve the referral rate of community DR.

30 March 2022 in Asia-Pacific Journal of Ophthalmology
Verified
Journal Article
Open access
CZCe Zheng
Ce Zheng
HYHongfei Ye
Hongfei Ye
JYJianlong Yang
Jianlong Yang
PFPing Fei
Ping Fei
YQYingping Qiu
Yingping Qiu
PZPeiquan Zhao
Peiquan Zhao
Purpose: To develop and test semi-supervised generative adversarial networks (GANs) that detect retinal disorders on optical coherence tomography (OCT) images using a small-labeled dataset. Methods: From a public database, we randomly chose a small supervised dataset with 400 OCT images (100 choroidal neovascularization, 100 diabetic macular edema, 100 drusen, and 100 normal) and assigned all other OCT images to unsupervised dataset (107,912 images without labeling). We adopted a semi-supervised GAN and a supervised deep learning (DL) model for automatically detecting retinal disorders from OCT images. The performance of the 2 models was compared in 3 testing datasets with different OCT devices. The evaluation metrics included accuracy, sensitivity, specificity, and the area under the receiver operating characteristic curves. Results: The local validation dataset included 1000 images with 250 from each category. The independent clinical dataset included 366 OCT images using Cirrus OCT Shanghai Shibei Hospital and 511 OCT images using RTVue OCT from Xinhua Hospital respectively. The semi-supervised GANs classifier achieved better accuracy than supervised DL model (0.91 vs 0.86 for local cell validation dataset, 0.91 vs 0.86 in the Shanghai Shibei Hospital testing dataset, and 0.93 vs 0.92 in Xinhua Hospital testing dataset). For detecting urgent referrals (choroidal neovascularization and diabetic macular edema) from nonurgent referrals (drusen and normal) on OCT images, the semi-supervised GANs classifier also achieved better area under the receiver operating characteristic curves than supervised DL model (0.99 vs 0.97, 0.97 vs 0.96, and 0.99 vs 0.99, respectively). Conclusions: A semi-supervised GAN can achieve better performance than that of a supervised DL model when the labeled dataset is limited. The current study offers utility to various research and clinical studies using DL with relatively small datasets. Semi-supervised GANs can detect retinal disorders from OCT images using relatively small dataset.

22 September 2021 in BMC Ophthalmology
Verified
Journal Article
Open access
PDF file
ZQZhuyun Qian
Zhuyun Qian
XXXiaoling Xie
Xiaoling Xie
JYJianlong Yang
Jianlong Yang
YHYe Hongfei
Ye Hongfei
ZWZhilei Wang
Zhilei Wang
Xu ChenXu Chen
Xu Chen
Background: The purpose of this study was to implement and evaluate a deep learning (DL) approach for automatically detecting shallow anterior chamber depth (ACD) from two-dimensional (2D) overview anterior segment photographs. Methods: We trained a DL model using a dataset of anterior segment photographs collected from Shanghai Aier Eye Hospital from June 2018 to December 2019. A Pentacam HR system was used to capture a 2D overview eye image and measure the ACD. Shallow ACD was defined as ACD less than 2.4 mm. The DL model was evaluated by a five-fold cross-validation test in a hold-out testing dataset. We also evaluated the DL model by testing it against two glaucoma specialists. The performance of the DL model was calculated by metrics, including accuracy, sensitivity, specificity, and area under the receiver operating characteristic curve (AUC). Results: A total of 3753 photographs (1720 shallow AC and 2033 deep AC images) were assigned to the training dataset, and 1302 photographs (509 shallow AC and 793 deep AC images) were held out for two internal testing datasets. In detecting shallow ACD in the internal hold-out testing dataset, the DL model achieved an AUC of 0.86 (95% CI, 0.83–0.90) with 80% sensitivity and 79% specificity. In the same testing dataset, the DL model also achieved better performance than the two glaucoma specialists (accuracy of 80% vs. accuracy of 74 and 69%). Conclusions: We proposed a high-performing DL model to automatically detect shallow ACD from overview anterior segment photographs. Our DL model has potential applications in detecting and monitoring shallow ACD in the real world. Trial registration: http://clinicaltrials.gov, NCT04340635, retrospectively registered on 29 March 2020.

1 July 2019 in Journal of Cataract & Refractive Surgery
Verified
Journal Article
Closed access
YZYi Zhu
Yi Zhu
THTianrui He
Tianrui He
HZHaobin Zhu
Haobin Zhu
JCJili Chen
Jili Chen
JZJibo Zhou
Jibo Zhou
To determine static and dynamic pupillometry characteristics before and after implantable collamer lens (ICL) (V4 and V4c) implantation. Shanghai, China. Prospective consecutive observational case series. Patients who had either V4 or V4c ICL implantation were included in this observational study. An automatic quantitative pupillometry system (MonCv3) was used for pupillometry preoperatively and 1 week, 1 month, and 3 months after surgery. Static pupillometry measurements (pupil diameters [PDs] at 4 standardized illumination levels) and dynamic parameters (including initial PD, amplitude of contraction, latency of contraction, duration of contraction, velocity of contraction, latency of dilation, duration of dilation, and velocity of dilation) were measured. The study comprised 98 eyes (50 patients). Mesopic and low photopic PDs declined by 0.32 mm and 0.27 mm, respectively, at 3 months after ICL implantation; scotopic PD declined at 1 week and recovered to preoperative levels at 3 months; and high photopic PD remained unchanged. Regarding the pupil light reflex, contraction amplitude and velocity declined after surgery, whereas other dynamic parameters remained unchanged. The static and dynamic pupillary characteristics were similar between the V4 and V4c ICL groups. The V4 and V4c ICLs had similar influences on iris motility. ICL implantation had a miotic effect under mesopic and low photopic illumination conditions, resulting in decreases in pupil contraction amplitude and velocity in light reflexes.