David A Low

Dr. David A Low

Research Institute for Sport and Exercise Sciences, Liverpool John Moores University, Liverpool L3 3AF, UK
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 December 2011 in Nature Reviews Neurology
Verified
Journal Article
Closed access
CMChristopher J. Mathias
Christopher J. Mathias
David A LowDavid A Low
David A Low
VIValeria Iodice
Valeria Iodice
AOAndrew Owens
Andrew Owens
MKMojca Kirbiš
Mojca Kirbiš
RGRodney Grahame
Rodney Grahame

1 March 2011 in American Journal of Physiology-Regulatory, Integrative and Comparative Physiology
Verified
Journal Article
Closed access
PDF file
JPJames Pearson
James Pearson
David A LowDavid A Low
David A Low
ESEric Stöhr
Eric Stöhr
KKKameljit Kalsi
Kameljit Kalsi
LALeena Ali
Leena Ali
JGJosé González-Alonso
José González-Alonso
Heat stress increases limb blood flow and cardiac output (Q̇) in humans, presumably in sole response to an augmented thermoregulatory demand of the skin circulation. Here we tested the hypothesis that local hyperthermia also increases skeletal muscle blood flow at rest and during exercise. Hemodynamics, blood and tissue oxygenation, and muscle, skin, and core temperatures were measured at rest and during exercise in 11 males across four conditions of progressive whole body heat stress and at rest during isolated leg heat stress. During whole body heat stress, leg blood flow (LBF), Q̇, and leg (LVC) and systemic vascular conductance increased gradually with elevations in muscle temperature both at rest and during exercise ( r2 = 0.86–0.99; P < 0.05). Enhanced LBF and LVC were accompanied by reductions in leg arteriovenous oxygen (a-vO2) difference and increases in deep femoral venous O2 content and quadriceps tissue oxygenation, reflecting elevations in muscle and skin perfusion. The increase in LVC occurred despite an augmented plasma norepinephrine ( P < 0.05) and was associated with elevations in muscle temperature ( r2 = 0.85; P = 0.001) and arterial plasma ATP ( r2 = 0.87; P < 0.001). Isolated leg heat stress accounted for one-half of the increase in LBF with severe whole body heat stress. Our findings suggest that local hyperthermia also induces vasodilatation of the skeletal muscle microvasculature, thereby contributing to heat stress and exercise hyperemia. The increased limb muscle vasodilatation in these conditions of elevated muscle sympathetic vasoconstrictor activity is closely related to the rise in arterial plasma ATP and local tissue temperature.

1 September 2012 in Journal of Neurology, Neurosurgery & Psychiatry
Verified
Journal Article
Closed access
MAM. Asahina
M. Asahina
EVE. Vichayanrat
E. Vichayanrat
David A LowDavid A Low
David A Low
VIV. Iodice
V. Iodice
CMC. J. Mathias
C. J. Mathias
Parkinson's disease (PD) is a progressive neurodegenerative disorder characterised by motor dysfunction (parkinsonism) and several non-motor features. Dysautonomia is a significant non-motor feature as well as a neuropsychiatric symptom. Autonomic dysfunction can occur even in the early stages of PD, often preceding the onset of the classic motor symptoms of PD. The patterns of autonomic features in PD are different from other parkinsonian disorders. Detection of autonomic dysfunction may therefore be helpful in diagnosing PD in the early or pre-motor stages, and/or in differentiating it from other parkinsonian disorders, such as multiple system atrophy and progressive supuranuclear palsy. The aim of this review is to describe aspects of autonomic dysfunction, including symptoms, assessment and pathophysiology, resulting from autonomic impairment in PD and other parkinsonian syndromes.

1 November 2010 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
JWJonathan E. Wingo
Jonathan E. Wingo
David A LowDavid A Low
David A Low
DKDavid M. Keller
David M. Keller
RBR. Matthew Brothers
R. Matthew Brothers
MSManabu Shibasaki
Manabu Shibasaki
CCCraig G. Crandall
Craig G. Crandall
Sweat rate (SR) is reduced in locally cooled skin, which may result from decreased temperature and/or parallel reductions in skin blood flow. The purpose of this study was to test the hypotheses that decreased skin blood flow and decreased local temperature each independently attenuate sweating. In protocols I and II, eight subjects rested supine while wearing a water-perfused suit for the control of whole body skin and internal temperatures. While 34°C water perfused the suit, four microdialysis membranes were placed in posterior forearm skin not covered by the suit to manipulate skin blood flow using vasoactive agents. Each site was instrumented for control of local temperature and measurement of local SR (capacitance hygrometry) and skin blood flow (laser-Doppler flowmetry). In protocol I, two sites received norepinephrine to reduce skin blood flow, while two sites received Ringer solution (control). All sites were maintained at 34°C. In protocol II, all sites received 28 mM sodium nitroprusside to equalize skin blood flow between sites before local cooling to 20°C (2 sites) or maintenance at 34°C (2 sites). In both protocols, individuals were then passively heated to increase core temperature ∼1°C. Both decreased skin blood flow and decreased local temperature attenuated the slope of the SR to mean body temperature relationship (2.0 ± 1.2 vs. 1.0 ± 0.7 mg·cm−2·min−1·°C−1 for the effect of decreased skin blood flow, P = 0.01; 1.2 ± 0.9 vs. 0.07 ± 0.05 mg·cm−2·min−1·°C−1 for the effect of decreased local temperature, P = 0.02). Furthermore, local cooling delayed the onset of sweating (mean body temperature of 37.5 ± 0.4 vs. 37.6 ± 0.4°C, P = 0.03). These data demonstrate that local cooling attenuates sweating by independent effects of decreased skin blood flow and decreased local skin temperature.

31 May 2006 in The Journal of Physiology
Verified
Journal Article
Open access
PDF file
DKD. M. Keller
D. M. Keller
JCJ. Cui
J. Cui
SDS. L. Davis
S. L. Davis
David A LowDavid A Low
David A Low
CCC. G. Crandall
C. G. Crandall
The relationship between muscle sympathetic nerve activity (MSNA) and diastolic blood pressure has been used to describe two sites for arterial baroreflex control of MSNA. By determining both the likelihood of occurrence for sympathetic bursts and the area of each burst for a given diastolic blood pressure, both a ‘gating’ and an ‘area’ control site has been described in normothermic humans. Assessing the effect of heat stress on these mechanisms will improve the understanding of baroreflex control of arterial blood pressure under this thermal condition. Therefore, the purpose of this study was to test the hypothesis that heat stress enhances arterial baroreflex control of burst gating and area. In 10 normotensive subjects (age, 32 ± 2 years; mean ±s.e.m.), MSNA (peroneal) was assessed using standard microneurographic techniques. Five minute periods of data were examined during normothermic and whole‐body heating conditions. The burst incidence (i.e. number of sympathetic bursts per 100 cardiac cycles) and the area of each burst were determined for each cardiac cycle and were placed into 3 mmHg intervals of diastolic blood pressure. During normotheric conditions, there was a moderate, negative relationship between burst incidence and diastolic blood pressure (slope =−2.49 ± 0.38; r2= 0.73 ± 0.06; mean ±s.e.m.), while area per burst relative to diastolic blood pressure exhibited a less strong relationship (slope =–1.13 ± 0.46; r2= 0.45 ± 0.09). During whole‐body heating there was an increase in the slope of the relationship between burst incidence and diastolic blood pressure (slope =–4.69 ± 0.44; r2= 0.84 ± 0.03) compared to normothermia (P < 0.05), while the relationship between area per burst and diastolic blood pressure was unchanged (slope =–0.92 ± 0.29; r2= 0.41 ± 0.08) (P= 0.50). The primary finding of this investigation is that, at rest, whole‐body heating enhanced arterial baroreflex control of MSNA through increased sensitivity of a ‘gating’ mechanism, as indicated by an increase in the slope of the relationship between burst incidence and diastolic blood pressure. This occurrence is likely to afford protection against potential decreases in arterial blood pressure in an effort to preserve orthostatic tolerance during heat stress.

1 November 2011 in Journal of Applied Physiology
Verified
Journal Article
Closed access
PDF file
David A LowDavid A Low
David A Low
DKDavid M. Keller
David M. Keller
JWJonathan E. Wingo
Jonathan E. Wingo
RBR. Matthew Brothers
R. Matthew Brothers
CCCraig G. Crandall
Craig G. Crandall
We and others have shown that moderate passive whole body heating (i.e., increased internal temperature ∼0.7°C) increases muscle (MSNA) and skin sympathetic nerve activity (SSNA). It is unknown, however, if MSNA and/or SSNA continue to increase with more severe passive whole body heating or whether these responses plateau following moderate heating. The aim of this investigation was to test the hypothesis that MSNA and SSNA continue to increase from a moderate to a more severe heat stress. Thirteen subjects, dressed in a water-perfused suit, underwent at least one passive heat stress that increased internal temperature ∼1.3°C, while either MSNA (n = 8) or SSNA (n = 8) was continuously recorded. Heat stress significantly increased mean skin temperature (Δ∼5°C, P < 0.001), internal temperature (Δ∼1.3°C, P < 0.001), mean body temperature (Δ∼2.0°C, P < 0.001), heart rate (Δ∼40 beats/min, P < 0.001), and cutaneous vascular conductance [Δ∼1.1 arbitrary units (AU)/mmHg, P < 0.001]. Mean arterial blood pressure was well maintained (P = 0.52). Relative to baseline, MSNA increased midway through heat stress (Δ core temperature 0.63 ± 0.01°C) when expressed as burst frequency (26 ± 14 to 45 ± 16 bursts/min, P = 0.001), burst incidence (39 ± 13 to 48 ± 14 bursts/100 cardiac cyles, P = 0.03), or total activity (317 ± 170 to 489 ± 150 units/min, P = 0.02) and continued to increase until the end of heat stress (burst frequency: 61 ± 15 bursts/min, P = 0.01; burst incidence: 56 ± 11 bursts/100 cardiac cyles, P = 0.04; total activity: 648 ± 158 units/min, P = 0.01) relative to the mid-heating stage. Similarly, SSNA (total activity) increased midway through the heat stress (normothermia; 1,486 ± 472 to mid heat stress 6,467 ± 5,256 units/min, P = 0.03) and continued to increase until the end of heat stress (11,217 ± 6,684 units/min, P = 0.002 vs. mid-heat stress). These results indicate that both MSNA and SSNA continue to increase as internal temperature is elevated above previously reported values.