Ying Zhou

Mrs. Ying Zhou

Jiaxing Center for Disease Control and Prevention

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
29 September 2018 in Molecules
Verified
Journal Article
Open access
PDF file
YZYing Zhou
Ying Zhou
JGJian Guan
Jian Guan
WGWeiwei Gao
Weiwei Gao
SLShencong Lv
Shencong Lv
MGMiaohua Ge
Miaohua Ge
In this research, fifteen carbamate pesticide residues were systematically analyzed by ultra-high performance liquid chromatography–quadrupole-linear ion trap mass spectrometry on a QTRAP 5500 system in both multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan modes. The carbamate pesticide residues were extracted from a variety of samples by QuEChERS method and separated by a popular reverse phase column (Waters BEH C18). Except for the current conformation criteria including selected ion pairs, retention time and relative intensities from MRM scan mode, the presence of carbamate pesticide residues in diverse samples, especially some doubtful cases, could also be confirmed by the matching of carbamate pesticide spectra via EPI scan mode. Moreover, the fragmentation routes of fifteen carbamates were firstly explained based on the mass spectra obtained by a QTRAP system; the characteristic fragment ion from a neutral loss of CH3NCO (−57 Da) could be observed. The limits of detection and quantification for fifteen carbamates were 0.2–2.0 μg kg−1 and 0.5–5.0 μg kg−1, respectively. For the intra- (n = 3) and inter-day (n = 15) precisions, the recoveries of fifteen carbamates from spiked samples ranged from 88.1% to 118.4%, and the coefficients of variation (CVs) were all below 10%. The method was applied to pesticide residues detection in fruit, vegetable and green tea samples taken from local markets, in which carbamates were extensively detected but all below the standard of maximum residue limit.

28 April 2015 in Molecules
Verified
Journal Article
Open access
PDF file
YZYing Zhou
Ying Zhou
DWDatong Wu
Datong Wu
PCPengfei Cai
Pengfei Cai
GCGuifang Cheng
Guifang Cheng
CHchaobiao Huang
chaobiao Huang
YPYuanjiang Pan
Yuanjiang Pan
A microwave-assisted extraction approach based on ionic liquids of different chain lengths was successfully applied to the extraction of ten flavonoid glycosides from the flowering heads of Chrysanthemum morifolium Ramat. The pretreated sample was quantified by HPLC-ESI-MSn. The main components were identified as flavonoid glycosides, including three luteolin glycosides, three apigenin glycosides, three kaempferide glycosides, and one acacetin glycoside according to the characteristics of the corresponding CID mass spectrometric patterns. Eight ionic liquids from the imidazolium family with different chain lengths, namely, 1-alkyl-3-methylimidazolium bromide, [Cnmim]Br, (n = 2–16) were studied as extraction medium in water. Results indicated that alkyl chain length had an irregular impact on the extraction efficiency. Moreover, the best extraction efficiency was achieved by 1-dodecyl-3-methylimidazolium bromide aqueous solution ([C12mim]Br). Besides the alkyl chain length of the cations, other factors influencing extraction efficiency were systematically investigated, including concentration of the IL solutions, extraction time, matrix-to-solvent ratio and irradiation power.

21 August 2023 in Separations
Verified
Journal Article
Open access
PDF file
XWXiaoqiong Wu
Xiaoqiong Wu
YLYun Lin
Yun Lin
XZXiang Zhang
Xiang Zhang
NONan Ouyang
Nan Ouyang
YZYing Zhou
Ying Zhou
The present study employed a modified QuEChERS method to systematically analyze the presence of fifteen quinolone and seven tetracycline antibiotic residues in local animal food. Additionally, a multi-level four-factor Box–Behnken design (BBD) within the framework of response surface methodology (RSM) was utilized to evaluate the factors impacting the detection efficiency of the sample pretreatment procedure. Optimization was performed via Design Expert® 10.0.3, and the factors, including the volume of the acetonitrile, the addition of formic acid, the duration of the extraction, and the addition of EDTA, were combined with experimental design until an optimal solution was reached. Finally, the sample was tested via ultra-high performance liquid chromatography-quadrupole-linear ion trap mass spectrometry (UPLC/MS/MS) in both multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan modes on a QTRAP® 5500 instrument (AB SCIEX instruments, Framingham, MA, USA). The overall average recoveries from actual samples fortified with 22 antibiotics at three levels ranged from 73.8% to 98.5% based on the use of matrix-fortified calibration, with variations ranging from 5.80 to 12.4% (n = 6). The limits of detection and quantification were 0.3 μg kg−1 and 1.0 μg kg−1, respectively. Lastly, the modified method was applied to practical sample analysis in the daily risk monitoring and assessment of food safety with satisfactory stability and robustness.

3 July 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
XWXiaoqiong Wu
Xiaoqiong Wu
YLYun Lin
Yun Lin
XZXiang Zhang
Xiang Zhang
NONan Ouyang
Nan Ouyang
YZYing Zhou
Ying Zhou
The present study employed a modifed QuEChERS method to systematically analyze the presence of fifteen Quinolones and seven Tetracyclines antibiotic residues in local animal food. Additionally, a multi-level-four-factor Box-Behnken design (BBD) within the framework of Response surface methodology (RSM) was utilized to evaluate the various factors affecting the detection efficiency of the sample pretreament procedure. The optimization was performed by Design Expert®, the factors including volume of the acetonitrle, the addition of formic acid, the duration of extract and the addition of EDTA were combined to experiment design until reach an optimal solution. Finally, the sample test was conducted by ultra-high performance liquid chromatography-quadrupole-linear ion trap mass spectrometry in both multiple reaction monitoring (MRM) and enhanced product ion (EPI) scan modes on a QTRAP® 5500 instrument. The overall average recoveries from actual samples fortified with 22 antibiotics at three levels ranged from 74.7 to 122.6% based on the use of matrix-fortified calibration with the variation ranging from 2.1 to 18.2% (n=6). The limits of detection and quantification were 0.3 μg kg-1 and 1.0 μg kg-1, respectively.