Khalid M. Abdelaziz

Dr. Khalid M. Abdelaziz

orcid

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2006 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
AAAhmed Attia
Ahmed Attia
KAKhalid M. Abdelaziz
Khalid M. Abdelaziz
SFSandra Freitag
Sandra Freitag
Matthias KernMatthias Kern
Matthias Kern

1 September 2003 in The Journal of Prosthetic Dentistry
Verified
Journal Article
Closed access
JTJonathan O Twomey
Jonathan O Twomey
KAKhalid M. Abdelaziz
Khalid M. Abdelaziz
ECEdward C Combe
Edward C Combe
DADwight L Anderson
Dwight L Anderson

1 December 2004 in Brazilian Dental Journal
Verified
Journal Article
Open access
PDF file
KAKhalid M. Abdelaziz
Khalid M. Abdelaziz
AHAhmed M. Hassan
Ahmed M. Hassan
JHJ.S. Hodges
J.S. Hodges
Impressions, dentures and other dental appliances may be contaminated with oral micro-flora or other organisms of varying pathogenicity from patient's saliva and blood. Several approaches have been tried to control the transmission of infectious organisms via dental impressions and because disinfection is less effective and has several drawbacks for impression characterization, several sterilization methods have been suggested. This study evaluated the reproducibility of rubber impressions after sterilization by different methods. Dimensional accuracy and wettability of two rubber impression materials (vinyl polysiloxane and polyether) were evaluated after sterilization by each of three well-known methods (immersion in 2% glutaraldehyde for 10 h, autoclaving and microwave radiation). Non-sterilized impressions served as control. The effect of the tray material on impression accuracy and the effect of topical surfactant on the wettability were also evaluated. One-way ANOVA with Dunnett's method was used for statistical analysis. All sterilizing methods reduced the reproducibility of rubber impressions, although not always significantly. Microwave sterilization had a small effect on both accuracy and wettability. The greater effects of the other methods could usually be overcome by using ceramic trays and by spraying impression surfaces with surfactant before pouring the gypsum mix. There was one exception: glutaraldehyde still degraded dimensional accuracy even with ceramic trays and surfactant. We conclude that a) sterilization of rubber impressions made on acrylic trays was usually associated with a degree of dimensional change; b) microwave energy seems to be a suitable technique for sterilizing rubber impressions; c) topical surfactant application helped restore wettability of sterilized impressions.

1 September 2002 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
KAKhalid M. Abdelaziz
Khalid M. Abdelaziz
ECEdward C. Combe
Edward C. Combe
JHJames S. Hodges
James S. Hodges

1 December 2002 in Journal of Prosthodontics
Verified
Journal Article
Closed access
PDF file
KAKhalid M. Abdelaziz
Khalid M. Abdelaziz
ECEdward C. Combe
Edward C. Combe
JHJames S. Hodges
James S. Hodges

9 June 2021 in BMC Oral Health
Verified
Journal Article
Open access
PDF file
RSRania A. Sharif
Rania A. Sharif
KAKhalid M. Abdelaziz
Khalid M. Abdelaziz
NANajla M. Alshahrani
Najla M. Alshahrani
FAFatimah S. Almutairi
Fatimah S. Almutairi
MAMohrah A. Alaseri
Mohrah A. Alaseri
MEMohamed Fadul A. Elagib
Mohamed Fadul A. Elagib
Background: Manufacturers of the extended-pour alginates claimed their dimensional stability through prolonged storage. No data confirmed the ability of these materials to maintain their dimensions and the reproduced oral details following their chemical disinfection. Therefore, this study evaluated the dimensional stability and surface detail reproduction of gypsum casts obtained from disinfected extended-pour alginate impressions through different storage time intervals. Methods: Two hundred and forty three hydrocolloid impressions were made from one conventional (Tropicalgin) and two extended-pour (Hydrogum 5 and Chromaprint premium) alginates. These impressions were subjected to none, spray and immersion disinfection before their storage in 100% humidity for 0, 72 and 120 h. The dimensional stability and the surface detail reproduction were indirectly evaluated under low angle illumination on the resulted gypsum casts. At α = 0.05, the parametric dimensional stability data were analyzed using One-Way ANOVA and Tukey’s comparisons, while the nonparametric detail reproduction data were analyzed using KrusKal Wallis and Mann–Whitney's tests. Results: All gypsum casts exhibited a degree of expansion; however, the recorded expansion values did not differ between test categories (P > 0.05). Generally, casts obtained from spray-disinfected impressions showed lower detail accuracy (P < 0.05). Immersion-disinfected extended-pour alginates produced casts with better detail accuracy following 120 h of storage (P < 0.05). Conclusion: All alginates materials offer comparable cast dimensions under different testing circumstances. Extended-pour alginates offer casts with superior surface details following their immersion disinfection and 120 h of storage. Spray-disinfection using 5.25% sodium hypochlorite affects the surface details of casts obtained from conventional and extended-pour alginates adversely.