Background: This study aims to investigate the effects of the local application of doxycycline in the form of natrosol‐based gel on bone regeneration by examining critical defects in rat calvaria.Methods: Twenty‐four rats were randomly divided into three groups with eight animals each, according to the treatment received: BC (untreated, filled with blood clot), NAT (natrosol gel alone), and DOX (10% doxycycline gel). Four animals from each group were euthanized at 4 and 8 weeks postoperatively. In tomographic analysis, mean density in the region of the defect was calculated as a percentage relative to the native bone density. In histomorphometric analysis, the newly formed bone area was calculated as a percentage of the total area. The values obtained underwent analysis of variance and Tukey testing (P <0.05).Results: The mean percentage of tomographic density in the region of the defect at the end of 8 weeks was higher for DOX (44.37%), and statistical differences in this period were observed between DOX and NAT (33.10%) and DOX and BC (32.43%). Regarding new bone formation, at the end of 8 weeks, DOX (61.11%) also had the highest mean bone formation, and statistical differences were observed between DOX and NAT (34.61%) and DOX and BC (23.11%).Conclusion: It was observed that 10% doxycycline gel had a good effect on bone regeneration regarding the filling of critical defects in rat calvaria.
The objective of this study was to assess the primary stability and the osseointegration process in implants with different macrostructures (Cylindrical vs. Hybrid Conical) in rabbit tibiae. Twenty-four (24) rabbits were used, divided into 3 experimental periods (2, 4 and 8 weeks) with 8 animals each. Each animal bilaterally received 2 implants from each group in the tibial metaphysis: Cylindrical Implant (CI) and Hybrid Conical Implant (HCI). All implants were assessed for insertion torque. After the experimental periods, one of the implants in each group was submitted to the removal counter-torque test and descriptive histological analysis while the other implant was used for microtomographic and histometric analysis (%Bone-Implant Contact). HCI implants showed higher insertion torque (32.93 ± 10.61 Ncm vs. 27.99 ± 7.80 Ncm) and higher % of bone-implant contact in the 8-week period (79.08 ± 11.31% vs. 59.72 ± 11.29%) than CI implants. However, CI implants showed higher values of removal counter-torque than HCI implants in the 8-week period (91.05 ± 9.32 Ncm vs. 68.62 ± 13.70 Ncm). There were no differences between groups regarding microtomographic data. It can be concluded that HCI implants showed greater insertion torque and bone-implant contact in relation to CI implants in the period of 8 weeks when installed in cortical bone of rabbits.
The aim of this study was to evaluate the osseointegration of a hydrophilic surface (blasting + acid etching + immersion in isotonic solution) in comparison with that of a control surface (blasting + acid etching) using an experimental model of low-density bone. To perform the study, 24 rabbits were submitted to the installation of 4 implants in the iliac bone bilaterally: 2 implants with a control surface and 2 implants with a hydrophilic surface. The rabbits were euthanized at 2, 4, and 8 weeks after implant installation. After euthanasia, one implant from each surface was used to perform the removal torque analysis, and the other implant was used for the execution of non-decalcified histological sections and evaluation of the bone implant contact (% BIC) as well as the fraction of bone tissue area between the implant threads (% BBT). The implants with a hydrophilic surface presented higher %BIC (42.92 ± 2.85% vs. 29.49 ± 10.27%) and % BBT (34.32 ± 8.52% vs. 23.20 ± 6.75%) (p < 0.05) in the 2-week period. Furthermore, the hydrophilic surface presented higher removal torque in the 8-week period (76.13 ± 16.00 Ncm2 vs. 52.77 ± 13.49 Ncm2) (p<0.05). Implants with a hydrophilic surface exhibited acceleration in the process of osseointegration, culminating in greater secondary stability in low-density bone than in implants with a control surface.