The tempospatially modulated polarization interference imaging spectrometer (TSMPIIS) nominated by the Ministry of Scence and Technology, takes part in the “Eleventh Five-Year National Science and Technology Exhibition.” In order to improve the detecting precision of the TSMPIIS, its radiometric calibration scheme is proposed on the basis of the solar simulator, integrating sphere, monochromator, and spectroradiometer. Under the conditions of changing the exposure time and radiant brightness, the CCD linear responses for the TSMPIIS were first tested to validate the reliability of the radiometric calibration performed with a linear response model, and the linear errors were less than 0.15% and 1.15%, respectively. A novel method is put forward to calibrate the nonuniformity of CCD pixels, and the least squares method can commendably correct the uneven effect in the spatial direction. Besides, the absolute radiometric calibration establishes a corresponding relation between the dimensionless intensity output from the TSMPIIS and the target radiant brightness. The study lays the foundation for the engineering application of the TSMPIIS, such as remote sensing detection, and has an important significance for the development of our instrument and equipment technology with independent intellectual property rights.
Aiming at the major demand for polarization information gap in earth observation and space exploration, we proposed a four-quadrant retarder array imaging spectropolarimeter (FQRAISP) in view of the existing technical problem of the spectral resolution degradation along with spectral aliasing crosstalk. The optical schematic diagram of the FQRAISP together with its interference model was conceptually described, and the effectiveness of the scheme was validated through the experimental simulation, which demonstrated the competitive efficiency and accuracy in the proposed FQRAISP. The FQRAISP could restore the incident Stokes vector spectrum without any errors, and the inversion accuracy was increased by seven times, avoiding the spectrum aliasing and channel filtering in the channel modulation. In order to evaluate the influences of the alignment deviation of four-partition phase retarder component, together with its thickness deviation on the reconstructed Stokes parameters, the numerical simulations were carried out, and the results showed that the alignment deviations had a relatively weak effect on the reconstructed Stokes spectra, while the thickness deviations had an obvious influence. Therefore, the alignment deviations controlled in a range of and together with the thickness deviations in a range of [ − 0.03µm, + 0.03µm] were an optimal choice for the engineering implementation of the FQRAISP. This research provided a novel method for the hardware realization of the accurate acquisition of all-optical information, having broad application prospects in remote sensing (deep space exploration), biomedicine and other fields.
13 February 2025 in IEEE Transactions on Geoscience and Remote Sensing
In order to ensure the accuracy and reliability of the observational data from the remote sensor during its on-orbit operation, a sampling correction approach with the interpolation sliding window (ISWSCA) is proposed on the basis of the quadratic fitting and interpolation correction. The ISWSCA mitigates the effects of the inhomogeneous distribution of the reflective properties on the lunar surface, significantly enhancing the sampling correction accuracy of the lunar observation data by incorporating a subpixel correction term. Based on the lunar observation data from the Fengyun-3D (FY-3D)/Medium Resolution Spectral Imager (MERSI)-II collected between 2018 and 2023, the feasibility of the ISWSCA is verified, and the ISWSCA improves the sampling correction accuracy by 2.13% and 5.25% during low and high lunar phases in comparison to the scaling method of the lunar full-disk irradiance (LFDISM), together with the correction accuracy improved by 1.37% and 6% in low and high spatial resolutions. The ISWSCA gives the long time series of the normalized calibration coefficient, together with the calibration uncertainty of the effective data being analyzed, and the results show that the on-orbit stability of the FY-3D satellite is excellent in the visible (VIS) and near-infrared (NIF) bands, with the attenuation rate below 1.29% and the calibration uncertainty within 2.11%. This study has an important significance for the on-orbit radiation calibration of the spatial remote sensor.