Free-standing N-CNF–Co/CoOx electrodes were fabricated by electrospinning followed by thermal pyrolysis. Controlled atomic layer deposition of Pd NPs on these nanofibers significantly increased electrode electrochemical activity in water splitting.
TiO2–BN–Pd materials were successfully prepared by combining electrospinning and atomic layer deposition. The obtained materials show outstanding properties for the degradation of acetaminophen (ACT) under UV and visible light as well as high stability and recyclability.
We developed free-standing nitrogen-doped carbon nanofiber (CNF) electrodes incorporating Co/CoOx nanoparticles (NPs) as a new cathode material for removing Acid Orange 7 (AO7; a dye for wool) from wastewater by the heterogeneous electro-Fenton reaction. We produced the free-standing N-doped CNF electrodes by electrospinning a polyacrylonitrile (PAN) and cobalt acetate solution followed by thermal carbonation of the cobalt acetate/PAN nanofibers under a nitrogen atmosphere. We then investigated electro-Fenton-based removal of AO7 from wastewater with the free-standing N-doped-CNFs-Co/CoOx electrodes, in the presence or not of Fe2+ ions as a co-catalyst. The electrochemical analysis showed the high stability of the prepared N-doped-CNF-Co/CoOx electrodes in electrochemical oxidation experiments with excellent degradation of AO7 (20 mM) at acidic to near neutral pH values (3 and 6). Electro-Fenton oxidation at 10 mA/cm2 direct current for 40 min using the N-doped-CNF-Co/CoOx electrodes loaded with 25 wt% of Co/CoOx NPs led to complete AO7 solution decolorization with total organic carbon (TOC) removal values of 92.4% at pH 3 and 93.3% at pH 6. The newly developed N-doped-CNF-Co/CoOx electrodes are an effective alternative technique for wastewater pre-treatment before the biological treatment.
7 December 2020 in Journal of Materials Chemistry B
Peritendinous adhesions cause chronic pain and disability. Leading causes are trauma to tendons and surrounding tissues and immobilization after surgery. Adhesions occur between 24 hours to 6 weeks after surgery. Anti-adhesion barriers are currently the best option available to prevent peritendinous adhesions, but are ineffective and difficult to use. We developed an anti-adhesive membrane that can be easily applied during tendon surgery and effectively prevent adhesions. The membrane is based on a new triblock copolymer, is non-toxic, can be bio-eliminated, and has a degradation rate of more than 6 weeks for optimal anti-adhesion effect. We synthesized and characterized poly(ether urethane) (PEU) from poly(ethylene glycol). Triblock copolymers poly(lactic acid)–PEU–poly(lactic acid) (PLA–PEU–PLA) were then synthesized from PEU with PLA blocks of different lengths, and characterized. The membranes were shaped by hot molding and their mechanical properties, contact angle, water uptake, the kinetics of in vitro degradation and cytotoxicity were studied. Mechanical properties were developed according to the needs of orthopaedic surgeons. Results showed that membranes maintained their filmogenic integrity, have a degradation rate for optimal adhesion prevention, can be bioeliminated and biocompatible suggesting that they could be safely and effectively used as anti-adhesion orthopaedic devices. These results support the use of PLA–PEU–PLA membranes as a medical device, however, the effectiveness of the membranes in vivo needs to be further evaluated. A future study using an in vivo rat model of postoperative peritendinous adhesions is currently being developed.