Philip Rowe

Prof. Philip Rowe

orcid

Research Focus & Metrics

Academic Career Length

38Years (1989-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 October 2011 in Clinical Rehabilitation
Verified
Journal Article
Closed access
FCFiona Coupar
Fiona Coupar
APAlex Pollock
Alex Pollock
PRPhilip Rowe
Philip Rowe
CWChristopher Weir
Christopher Weir
PLPeter Langhorne
Peter Langhorne
Objective: To systematically review and summarize the current available literature on prognostic variables relating to upper limb recovery following stroke. To identify which, if any variables predict upper limb recovery following stroke. Data sources: We completed searches in MEDLINE, EMBASE, AMED, CINAHL and Cochrane CENTRAL databases. Searches were completed in November 2010. Review methods: Studies were included if predictor variables were measured at baseline and linked to an outcome of upper limb recovery at a future time point. Exclusion criteria included predictor variables relating to response to treatment and outcome measurements of very specific upper limb impairments such as spasticity or pain. Two independent reviewers completed data extraction and assessed study quality. Results: Fifty-eight studies met the inclusion criteria. Predictor variables which have been considered within these studies include; age, sex, lesion site, initial motor impairment, motor-evoked potentials andsomatosensory-evoked potentials. Initial measures of upper limb impairment and function were found to be the most significant predictors of upper limb recovery; odds ratio 14.84 (95% confidence intervals (CI) 9.08–24.25) and 38.62 (95% CI 8.40–177.53), respectively. Conclusions: Interpretation of these results is complicated by methodological factors including variations in study populations, upper limb motor outcome scales, timing of baseline and outcome assessments and predictors selected. The most important predictive factors for upper limb recovery following stroke appears to the initial severity of motor impairment or function.

1 October 2000 in Gait & Posture
Verified
Journal Article
Closed access
PRPhilip Rowe
Philip Rowe
CMC.M. Myles
C.M. Myles
CWC. Walker
C. Walker
RNR. Nutton
R. Nutton

20 April 2016 in Journal of Bone and Joint Surgery
Verified
Journal Article
Closed access
PDF file
SBStuart W. Bell
Stuart W. Bell
IAIain Anthony
Iain Anthony
BJBryn Jones
Bryn Jones
AMAngus MacLean
Angus MacLean
PRPhilip Rowe
Philip Rowe
MBMark Blyth
Mark Blyth
Background: Higher revision rates have been reported in patients who have undergone unicompartmental knee arthroplasty compared with patients who have undergone total knee arthroplasty, with poor component positioning identified as a factor in implant failure. A robotic-assisted surgical procedure has been proposed as a method of improving the accuracy of component implantation in arthroplasty. The aim of this prospective, randomized, single-blinded, controlled trial was to evaluate the accuracy of component positioning in unicompartmental knee arthroplasty comparing robotic-assisted and conventional implantation techniques. Methods: One hundred and thirty-nine patients were randomly assigned to treatment with either a robotic-assisted surgical procedure using the MAKO Robotic Interactive Orthopaedic Arm (RIO) system or a conventional surgical procedure using the Oxford Phase-3 unicompartmental knee replacement with traditional instrumentation. A postoperative computed tomographic scan was performed at three months to assess the accuracy of the axial, coronal, and sagittal component positioning. Results: Data were available for 120 patients, sixty-two who had undergone robotic-assisted unicompartmental knee arthroplasty and fifty-eight who had undergone conventional unicompartmental knee arthroplasty. Intraobserver agreement was good for all measured component parameters. The accuracy of component positioning was improved with the use of the robotic-assisted surgical procedure, with lower root mean square errors and significantly lower median errors in all component parameters (p < 0.01). The proportion of patients with component implantation within 2° of the target position was significantly greater in the group who underwent robotic-assisted unicompartmental knee arthroplasty compared with the group who underwent conventional unicompartmental knee arthroscopy with regard to the femoral component sagittal position (57% compared with 26%, p = 0.0008), femoral component coronal position (70% compared with 28%, p = 0.0001), femoral component axial position (53% compared with 31%, p = 0.0163), tibial component sagittal position (80% compared with 22%, p = 0.0001), and tibial component axial position (48% compared with 19%, p = 0.0009). Conclusions: Robotic-assisted surgical procedures with the use of the MAKO RIO lead to improved accuracy of implant positioning compared with conventional unicompartmental knee arthroplasty surgical techniques. Level of Evidence: Therapeutic Level I. See Instructions for Authors for a complete description of levels of evidence.

1 December 2013 in Physiotherapy
Verified
Journal Article
Closed access
BCBruce Carse
Bruce Carse
BMBarry Meadows
Barry Meadows
RBRoy Bowers
Roy Bowers
PRPhilip Rowe
Philip Rowe

1 July 2018 in The Journal of Arthroplasty
Verified
Journal Article
Closed access
AGAlisdair Gilmour
Alisdair Gilmour
AMAngus D. MacLean
Angus D. MacLean
PRPhilip Rowe
Philip Rowe
MBMatthew S. Banger
Matthew S. Banger
IDIona Donnelly
Iona Donnelly
MBMark J.G. Blyth
Mark J.G. Blyth

1 November 2017 in Bone & Joint Research
Verified
Journal Article
Open access
MBM. J. G. Blyth
M. J. G. Blyth
IAI. Anthony
I. Anthony
PRPhilip Rowe
Philip Rowe
MBM. S. Banger
M. S. Banger
AMA. MacLean
A. MacLean
BJB. Jones
B. Jones
Objectives: This study reports on a secondary exploratory analysis of the early clinical outcomes of a randomised clinical trial comparing robotic arm-assisted unicompartmental knee arthroplasty (UKA) for medial compartment osteoarthritis of the knee with manual UKA performed using traditional surgical jigs. This follows reporting of the primary outcomes of implant accuracy and gait analysis that showed significant advantages in the robotic arm-assisted group.Methods: A total of 139 patients were recruited from a single centre. Patients were randomised to receive either a manual UKA implanted with the aid of traditional surgical jigs, or a UKA implanted with the aid of a tactile guided robotic arm-assisted system. Outcome measures included the American Knee Society Score (AKSS), Oxford Knee Score (OKS), Forgotten Joint Score, Hospital Anxiety Depression Scale, University of California at Los Angeles (UCLA) activity scale, Short Form-12, Pain Catastrophising Scale, somatic disease (Primary Care Evaluation of Mental Disorders Score), Pain visual analogue scale, analgesic use, patient satisfaction, complications relating to surgery, 90-day pain diaries and the requirement for revision surgery.Results: From the first post-operative day through to week 8 post-operatively, the median pain scores for the robotic arm-assisted group were 55.4% lower than those observed in the manual surgery group (p = 0.040). At three months post-operatively, the robotic arm-assisted group had better AKSS (robotic median 164, interquartile range (IQR) 131 to 178, manual median 143, IQR 132 to 166), although no difference was noted with the OKS. At one year post-operatively, the observed differences with the AKSS had narrowed from a median of 21 points to a median of seven points (p = 0.106) (robotic median 171, IQR 153 to 179; manual median 164, IQR 144 to 182). No difference was observed with the OKS, and almost half of each group reached the ceiling limit of the score (OKS > 43). A greater proportion of patients receiving robotic arm-assisted surgery improved their UCLA activity score. Binary logistic regression modelling for dichotomised outcome scores predicted the key factors associated with achieving excellent outcome on the AKSS: a pre-operative activity level > 5 on the UCLA activity score and use of robotic-arm surgery. For the same regression modelling, factors associated with a poor outcome were manual surgery and pre-operative depression.Conclusion: Robotic arm-assisted surgery results in improved early pain scores and early function scores in some patient-reported outcomes measures, but no difference was observed at one year post-operatively. Although improved results favoured the robotic arm-assisted group in active patients (i.e. UCLA ⩾ 5), these do not withstand adjustment for multiple comparisons. Cite this article: M. J. G. Blyth, I. Anthony, P. Rowe, M. S. Banger, A. MacLean, B. Jones. Robotic arm-assisted versus conventional unicompartmental knee arthroplasty: Exploratory secondary analysis of a randomised controlled trial. Bone Joint Res 2017;6:631–639. DOI: 10.1302/2046-3758.611.BJR-2017-0060.R1.