Weihuang Yang

Weihuang Yang


Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2022 in Life
Verified
Journal Article
Open access
PDF file
RHRui Hong
Rui Hong
HSHongyu Sun
Hongyu Sun
DLDujuan Li
Dujuan Li
WYWeihuang Yang
Weihuang Yang
KFKai Fan
Kai Fan
GWGaofeng Wang
Gaofeng Wang
Breast cancer has the highest cancer incidence rate in women. Early screening of breast cancer can effectively improve the treatment effect of patients. However, the main diagnostic techniques available for the detection of breast cancer require the corresponding equipment, professional practitioners, and expert analysis, and the detection cost is high. Tumor markers are a kind of active substance that can indicate the existence and growth of the tumor. The detection of tumor markers can effectively assist the diagnosis and treatment of breast cancer. The conventional detection methods of tumor markers have some shortcomings, such as insufficient sensitivity, expensive equipment, and complicated operations. Compared with these methods, biosensors have the advantages of high sensitivity, simple operation, low equipment cost, and can quantitatively detect all kinds of tumor markers. This review summarizes the biosensors (2013–2021) for the detection of breast cancer biomarkers. Firstly, the various reported tumor markers of breast cancer are introduced. Then, the development of biosensors designed for the sensitive, stable, and selective recognition of breast cancer biomarkers was systematically discussed, with special attention to the main clinical biomarkers, such as human epidermal growth factor receptor-2 (HER2) and estrogen receptor (ER). Finally, the opportunities and challenges of developing efficient biosensors in breast cancer diagnosis and treatment are discussed.

29 January 2019 in npj 2D Materials and Applications
Verified
Journal Article
Open access
PDF file
LWLixiang Wu
Lixiang Wu
WYWeihuang Yang
Weihuang Yang
GWGaofeng Wang
Gaofeng Wang
Controlled anisotropic growth of two-dimensional materials provides an approach for the synthesis of large single crystals and nanoribbons, which are promising for applications as low-dimensional semiconductors and in next-generation optoelectronic devices. In particular, the anisotropic growth of transition metal dichalcogenides induced by the substrate is of great interest due to its operability. To date, however, their substrate-induced anisotropic growth is typically driven by the optimization of experimental parameters without uncovering the fundamental mechanism. Here, the anisotropic growth of monolayer tungsten disulfide on an ST-X quartz substrate is achieved by chemical vapor deposition, and the mechanism of substrate-induced anisotropic growth is examined by kinetic Monte Carlo simulations. Results show that, besides the variation of substrate adsorption, the chalcogen to metal (C/M) ratio is a major contributor to the large growth anisotropy and the polarization of undergrowth and overgrowth; either perfect isotropy or high anisotropy can be expected when the C/M ratio equals 2.0 by properly controlling the linear relationship between gas flux and temperature.

31 October 2019 in Nano
Verified
Journal Article
Closed access
PDF file
QZQinqin Zhuang
Qinqin Zhuang
WYWeihuang Yang
Weihuang Yang
WLWei Lin
Wei Lin
LDLinxi Dong
Linxi Dong
CZChangjie Zhou
Changjie Zhou

8 August 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JCJiagen Cheng
Jiagen Cheng
YMYuanbin Mu
Yuanbin Mu
CLChaoran Liu
Chaoran Liu
WYWeihuang Yang
Weihuang Yang
WLWenjing Liu
Wenjing Liu
Linxi DongLinxi Dong
Linxi Dong
Pressure ulcers are a common and costly health problem in clinical medicine, caused primarily by continuous vertical pressure on local tissues of the body. Recently, flexible devices have been used to alert pressure ulcers by continuously monitoring the pressure applied to the human skin. Although many pressure sensors provide excellent sensing performance, they still rely on uncomfortable, unstretchable systems with rigid electronics. These devices are mounted on the human body, which hinders continuous pressure monitoring. Herein, we propose a fully integrated flexible electronic system (FIFES) with highly sensitive multi-walled carbon nanotubes (MWNTs) piezoresistive array sensors for pressure monitoring, which accurately achieves external pressure signals acquisition and independently performs processing and wireless transmission. We develop a heat seal connecting technology for integrating the piezoresistive array sensors and its flexible processing circuit, which overcomes the compatibility defect of a rigid circuit board and the flexible sensors. Furthermore, the Cu–Ge metal sputtering and transferring technologies are employed to achieve an extensible circuit. The as-fabricated fully integrated electronic system has excellent flexibility, a rapid response time (the response/recovery time is 0.11/0.08 s, respectively), a wide dynamic range (6–50 kPa), and an excellent sensitivity (1.61 kPa −1 for the range under the pressure of 18 kPa, 0.47 kPa −1 for the range of 18–50 kPa) attributes to the optimized conical microstructures number. Owing to its excellent performance, the FIFES has extensive applications for pressure monitoring in different human epidermises, such as elbow bending and knee-bending. Also, it has immense potential applications in sleep posture monitoring and pressure ulcer warning.

16 February 2023 in Discover Nano
Verified
Journal Article
Open access
PDF file
WYWeihuang Yang
Weihuang Yang
YMYuanbin Mu
Yuanbin Mu
XCXiangshuo Chen
Xiangshuo Chen
NJNingjing Jin
Ningjing Jin
JSJiahao Song
Jiahao Song
JLJing Li
Jing Li
Large-area, continuous monolayer WS2 exhibits great potential for future micro-nanodevice applications due to its special electrical properties and mechanical flexibility. In this work, the front opening quartz boat is used to increase the amount of sulfur (S) vapor under the sapphire substrate, which is critical for achieving large-area films during the chemical vapor deposition processes. COMSOL simulations reveal that the front opening quartz boat will significantly introduce gas distribute under the sapphire substrate. Moreover, the gas velocity and height of substrate away from the tube bottom will also affect the substrate temperature. By carefully optimizing the gas velocity, temperature, and height of substrate away from the tube bottom, a large-scale continues monolayered WS2 film was achieved. Field-effect transistor based on the as-grown monolayer WS2 showed a mobility of 3.76 cm2V−1 s−1 and ON/OFF ratio of 106. In addition, a flexible WS2/PEN strain sensor with a gauge factor of 306 was fabricated, showing great potential for applications in wearable biosensors, health monitoring, and human–computer interaction.

5 September 2022 in IEEE Sensors Journal
Verified
Journal Article
Closed access
WLWenjing Liu
Wenjing Liu
JCJiagen Cheng
Jiagen Cheng
ZWZutang WU
Zutang WU
JLJin Li
Jin Li
WSWei Shi
Wei Shi
Linxi DongLinxi Dong
Linxi Dong
Hypertension is a very significant public health problem and has become a potential risk for cardiovascular and renal diseases. Blood pressure (BP) including systolic BP (SBP) and diastolic BP (DBP) is a vital parameter that should be monitored regularly for the early detection and prevention of chronic diseases. The traditional cuff-based BP monitors can cause discomfort to the users due to inflation and deflation. Here, a wearable and flexible photoplethysmography (PPG) patch sensor based on the polydimethylsiloxane (PDMS) substrate and double-layer serpentine structure with a closed loop that can omit the transfer printing process is proposed for cuffless BP estimation. Three models are adopted to estimate the BP. The accuracy of SBP and DBP obtained are 3.68 ± 2.37 and 4.9 ± 3.78 mmHg for the first model and 3.61 ± 2.62 and 4.72 ± 3.46 mmHg for the second model, respectively. The third model introduces the Kalman filtering to optimize the solution of the coefficients of the second model to forecast BP. As a result, the accuracy of SBP and DBP as high as 2.94 ± 2.35 and 3.41 ± 2.94 mmHg, respectively, is realized. The results show that the introduction of the Kalman filter algorithm to forecast BP can not only reduce the number of calibrations, but also improve the accuracy of BP estimation.