Fotios Laspas

Mr. Fotios Laspas


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 October 2008 in Journal of Medical Imaging and Radiation Oncology
Verified
Journal Article
Closed access
PDF file
FLFotios Laspas
Fotios Laspas
ARA Roussakis
A Roussakis
RER Efthimiadou
R Efthimiadou
DPD Papaioannou
D Papaioannou
SPS Papadopoulos
S Papadopoulos
JAJ Andreou
J Andreou

12 January 2010 in Cases Journal
Verified
Journal Article
Open access
PDF file
ECEfstathios Chronopoulos
Efstathios Chronopoulos
NPNikolaos Ptohis
Nikolaos Ptohis
CKChristos Karanikas
Christos Karanikas
AKAlkis Kalliakmanis
Alkis Kalliakmanis
SPSpyros Plessas
Spyros Plessas
ACAthanasios Chalazonitis
Athanasios Chalazonitis
Introduction: Lipomas can be found anywhere in the body with the majority located in the head and neck region as well as in the shoulder and back. They are not very common in the hand and those involving the fingers are very rare. Although, it is not the only case reported, lipoma of the index finger is very uncommon. Case presentation: A 52-year-old Caucasian man presented with a lipoma of the right index finger. He complained of no pain but he had difficulty in manual movements. Treatment was surgical excision of the lipoma. There has been no recurrence for two years. Conclusion: Although lipomas of the fingers are rare entities, their awareness is imperative since the differential diagnosis from other soft tissue tumors and from the special lipomatous subtype involved is quite extensive.

1 January 2009 in World Journal of Gastroenterology
Verified
Journal Article
Open access
IKIoannis V Kalogeropoulos
Ioannis V Kalogeropoulos
ACAthanasios N Chalazonitis
Athanasios N Chalazonitis
STSofia Tsolaki
Sofia Tsolaki
FLFotios Laspas
Fotios Laspas
NPNikolaos Ptohis
Nikolaos Ptohis
DRDimitra Rontogianni
Dimitra Rontogianni
A case of primary isolated non-Hodgkin’s lymphoma of the esophagus in an immunocompetent patient

13 June 2011 in Gynecological Endocrinology
Verified
Journal Article
Closed access
VPVasileios Prassopoulos
Vasileios Prassopoulos
FLFotios Laspas
Fotios Laspas
FVFani Vlachou
Fani Vlachou
RERoxani Efthimiadou
Roxani Efthimiadou
LGLida Gogou
Lida Gogou
JAJohn Andreou
John Andreou
Androgen-producing ovarian tumours can lead to assessment difficulties because of their small size. We present a case of virilising steroid cell ovarian tumour in a 41-year-old woman localised with Fluorine-18-Deoxyglucose Positron Emission Tomography/Computed Tomography (18FDG-PET/CT). Although the biochemical evaluation pointed to an ovarian source of androgen, diagnostic attempts to localise the source of hyperandrogenism with transvaginal ultrasound (US), and magnetic resonance imaging (MRI) of pelvis failed. Additional evaluation with 18FDG-PET/CT showed an increased uptake in the right ovary. A laparoscopic right oophorectomy was performed and histopathology examination revealed a 1.2-cm Leydig cell tumour. The patient showed regression of clinical signs.

29 March 2020 in Diagnostics
Verified
Journal Article
Open access
PDF file
FLFotios Laspas
Fotios Laspas
TPTheodoros Pipikos
Theodoros Pipikos
EKEmmanouil Karatzis
Emmanouil Karatzis
NGNikolaos Georgakopoulos
Nikolaos Georgakopoulos
VPVasileios Prassopoulos
Vasileios Prassopoulos
PDPeter G. Danias
Peter G. Danias
Background: This study aimed to compare the diagnostic accuracy of stress single-photon emission computed tomography (SPECT) and stress cardiac magnetic resonance (CMR) for the assessment of coronary artery disease (CAD) in the same patients, using coronary angiography as the reference standard. Methods: Thirty patients with known or suspected CAD who were referred for exercise SPECT myocardial perfusion imaging (MPI) for the evaluation of myocardial ischemia underwent stress CMR MPI and computed tomography coronary angiography (CTCA) or selective coronary angiography (SCA). The data from the two stress modalities were compared against the data from angiography. Results: In our study population, 30% of the recruited subjects had significant CAD. The CMR sensitivity for the detection of significant CAD and/or myocardial ischemia was 89% and specificity was 76%. For SPECT, the corresponding sensitivity was 78% and specificity was 52%. The negative predictive value was 92% for CMR and 83% for SPECT. The receiver-operating characteristic (ROC) analysis evaluating the presence of significant CAD, CMR (area under the curve (AUC) 0.78) outperformed SPECT (AUC 0.59) (p < 0.01). The ROC analysis evaluating the presence of myocardial ischemia was also in favor of CMR (AUC 0.82) versus SPECT (AUC 0.67) (p < 0.01). Conclusions: CMR has high diagnostic accuracy for the detection of CAD and stress-induced ischemia and appears to outperform SPECT. CMR may thus be the preferred noninvasive imaging modality to assess patients with known or suspected CAD.

1 April 2011 in Acta Radiologica
Verified
Journal Article
Closed access
PDF file
FLFotios Laspas
Fotios Laspas
DTDimitra Tsantioti
Dimitra Tsantioti
ARArkadios Roussakis
Arkadios Roussakis
NKNikolaos Kritikos
Nikolaos Kritikos
RERoxani Efthimiadou
Roxani Efthimiadou
JAJohn Andreou
John Andreou
Background Computed tomography coronary angiography (CTCA) has been widely used since the introduction of 64-slice scanners and dual-source CT technology, but the relatively high radiation dose remains a major concern. Purpose To evaluate the relationship between radiation exposure and heart rate (HR), in dual-source CTCA. Material and Methods Data from 218 CTCA examinations, performed with a dual-source 64-slices scanner, were statistically evaluated. Effective radiation dose, expressed in mSv, was calculated as the product of the dose-length product (DLP) times a conversion coefficient for the chest (mSv = DLPx0.017). Heart rate range and mean heart rate, expressed in beats per minute (bpm) of each individual during CTCA, were also provided by the system. Statistical analysis of effective dose and heart rate data was performed by using Pearson correlation coefficient and two-sample t-test. Results Mean HR and effective dose were found to have a borderline positive relationship. Individuals with a mean HR >65 bpm observed to receive a statistically significant higher effective dose as compared to those with a mean HR ≤65 bpm. Moreover, a strong correlation between effective dose and variability of HR of more than 20 bpm was observed. Conclusion Dual-source CT scanners are considered to have the capability to provide diagnostic examinations even with high HR and arrhythmias. However, it is desirable to keep the mean heart rate below 65 bpm and heart rate fluctuation less than 20 bpm in order to reduce the radiation exposure.