Hong Wang

Dr. Hong Wang


Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 August 2014 in Journal of Clinical Anesthesia
Verified
Journal Article
Closed access
GTGokul Toshniwal
Gokul Toshniwal
GMGeorge M. McKelvey
George M. McKelvey
HWHong Wang
Hong Wang

1 December 2015 in BMC Anesthesiology
Verified
Journal Article
Open access
PDF file
WZWenwen Zhai
Wenwen Zhai
XWXuedong Wang
Xuedong Wang
YRYulan Rong
Yulan Rong
MLMin Li
Min Li
HWHong Wang
Hong Wang
Ultrasound guidance has reduced the amount of local anesthetics to achieve a successful block. Previous studies of the relationship between the volume or concentration of local anesthetics and the effects of the block were based on relatively high doses of local anesthetics. We tested the hypothesis that providing low dose of ropivacaine at three combinations of volumes and concentrations for ultrasound-guided interscalene brachial plexus block would produce different effects in the aspect of onset time, pain control and the incidence of side effects. Ninety-nine patients undergoing elective arthroscopic shoulder surgery were randomized to receive an ultrasound guided combined with nerve stimulator mediated interscalene block with ropivacaine 0.75 % (6.7 ml, Group 0.75), 0.5 % (10 ml, Group 0.5) or 0.25 % (20 ml, Group 0.25). The primary end point was the onset time of the sensory blockade, assessed by using a pinprick in the C5-6 dermatome. The secondary end points included the onset time of the motor blockade, block success rate, postoperative pain rating score, rescue analgesics requirement, sleep quality, strength of the hand on the block side,and the incidence of hemi-diaphragmatic paresis which was evaluated by ultrasonography. There was a statistically significant difference of the sensory block median onset times among Group 0.75 (5 min), Group 0.5 (10 min) and Group 0.25 (20 min). One patient in Group 0.5 and 20 patients in Group 0.25 did not achieve a complete motor block within 30 min, which were also significantly different. No significant difference was observed in postoperative analgesia, decrease of handgrip strength and the incidence of hemi-diaphragmatic paresis among the 3 groups. This study demonstrates that ropivacaine 50 mg as 0.25, 0.5 or 0.75 % solution for interscalene brachial plexus block before arthroscopic shoulder surgery produces comparable blockade with few side effects, while 0.75 % seems to be more preferable as it is associated with faster onset time. ChiCTR-TRC-13004058 . Registered 4 December 2013.

1 December 2011 in Journal of Clinical Anesthesia
Verified
Journal Article
Closed access
DGDeepak Gupta
Deepak Gupta
HWHong Wang
Hong Wang

1 January 2014 in Journal of Biomedical Research
Verified
Journal Article
Open access
PDF file
CDChoromanski Dominik
Choromanski Dominik
FJFrederick Joel
Frederick Joel
MGMichael George
Michael George
HWHong Wang
Hong Wang
Currently, no reported studies have evaluated intraoperative handover among anesthesia providers. Studies on anesthetic handover in the US recovery room setting observed that handover processes are insufficient and, in many instances, significant intraoperative events are disregarded. An online survey tool was sent to anesthesia providers at US anesthesia residency programs nationwide (120 out of the 132 US programs encompassing around 4500 residents and their academic MDAs) and a smaller survey selection of CRNAs (10 institutions about 300 CRNAs in the metropolitan area of Detroit, MI, USA) to collect information on handover practices. The response rate to this survey (n = 216) was comprised of approximately 5% (n = 71) of the resident population in US anesthesia programs, 5% (n = 87) of MDAs , and 20% (n = 58) of the CRNAs. Out of all respondents (n = 212), 49.1 % had no hand-over protocol at their institution and 88% of respondents who did have institutional handover protocols believed them insufficient for effective patient handover. In addiiton, 84.8% of all responders reported situations where there was insufficient information received during a patient handover. Only 7% of the respondents reported never experiencing complications or mismanagement due to poor or incomplete hand-overs. In contrast, 60% reported rarely having complications, 31% reported sometimes having complications, and 3% reported frequent complications. In conclusion, handover transition of patient care is a vulnerable and potentially life-threatening event in the operating room. Our preliminary study suggests that current intraoperatvive handover practices among anesthesia providers are suboptimal and that national patient handover guidelines are required to improve patient safety.

1 August 2014 in Journal of Clinical Anesthesia
Verified
Journal Article
Closed access
LGLakshman Gollapalli
Lakshman Gollapalli
GMGeorge McKelvey
George McKelvey
HWHong Wang
Hong Wang

1 January 2012 in Journal of Biomedical Research
Verified
Journal Article
Open access
PDF file
GDGupta Deepak
Gupta Deepak
SASrirajakalidindi Arvind
Srirajakalidindi Arvind
HWHong Wang
Hong Wang
EndoSheath bronchoscopy (Vision Sciences, Inc.) uses a sterile, disposable microbial barrier that may meet the growing needs for safe, efficient, and cost effective flexible bronchoscopy. The purpose of this open-label comparative study was to compare and calculate the costs-per-airway-procedure of the reusable fiberscope when used with and without EndoSheath(®) Technology; and to record the turnover time from the completion of the use of each scope until its readiness again for the next use. Seventy-five new patients' airways requiring airway maneuvers and manipulations with Vision Sciences, Inc., reusable fiberscope with EndoSheath(®) Technology were evaluated for the costs comparisons with reassessed historical costs data for Olympus scope assisted tracheal intubations. As compared to costs of an intubation ($158.50) with Olympus scope at our institute, the intubation costs with Vision Sciences, Inc., reusable fiberscope with EndoSheath technology was $81.50 (P < 0.001). The mean turnover time was 5.44 min with EndoSheath technology as compared to previously reported 30 min with Olympus fiberscope (P < 0.001). Based on our institutional experience, Vision Sciences, Inc., reusable fiberscope with EndoSheath technology is significantly cost effective as compared to the Olympus scope with significantly improved turnover times.