Satria Mandala

Dr. Satria Mandala

Humic Engineering, Telkom University, Bandung, Jawa Barat, Indonesia
orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 June 2017 in Journal of Medical and Biological Engineering
Verified
Journal Article
Open access
PDF file
Satria MandalaSatria Mandala
Satria Mandala
TDTham Cai Di
Tham Cai Di
Many studies showed electrocardiogram (ECG) parameters are useful for predicting fatal ventricular arrhythmias (VAs). However, the studies have several shortcomings. Firstly, all studies lack of effective way to present behavior of various ECG parameters prior to the occurrence of the VAs. Secondly, they also lack of discussion on how to consider the parameters as abnormal. Thirdly, the reports do not include approaches to increase the detection accuracy for the abnormal patterns. The purpose of this study is to address the aforementioned issues. It identifies ten ECG parameters from various sources and then presents a review based on the identified parameters. From the review, it has been found that the increased risk of VAs can be represented by presence and certain abnormal range of the parameters. The variation of parameters range could be influenced by either gender or age. This study also has discovered the facts that averaging, outliers elimination and morphology detection algorithms can contribute to the detection accuracy.

14 May 2020 in PLOS ONE
Verified
Journal Article
Open access
PDF file
Satria MandalaSatria Mandala
Satria Mandala
TDTham Cai Di
Tham Cai Di
MSMohd Shahrizal Sunar
Mohd Shahrizal Sunar
AAAdiwijaya Adiwijaya
Adiwijaya Adiwijaya
Spontaneous prediction of malignant ventricular arrhythmia (MVA) is useful to avoid delay in rescue operations. Recently, researchers have developed several algorithms to predict MVA using various features derived from electrocardiogram (ECG). However, there are several unresolved issues regarding MVA prediction such as the effect of number of ECG features on a prediction remaining unclear, possibility that an alert for occurring MVA may arrive very late and uncertainty in the performance of the algorithm predicting MVA minutes before onset. To overcome the aforementioned problems, this research conducts an in-depth study on the number and types of ECG features that are implemented in a decision tree classifier. In addition, this research also investigates an algorithm’s execution time before the occurrence of MVA to minimize delays in warnings for MVA. Lastly, this research aims to study both the sensitivity and specificity of an algorithm to reveal the performance of MVA prediction algorithms from time to time. To strengthen the results of analysis, several classifiers such as support vector machine and naive Bayes are also examined for the purpose of comparison study. There are three phases required to achieve the objectives. The first phase is literature review on existing relevant studies. The second phase deals with design and development of four modules for predicting MVA. Rigorous experiments are performed in the feature selection and classification modules. The results show that eight ECG features with decision tree classifier achieved good prediction performance in terms of execution time and sensitivity. In addition, the results show that the highest percentage for sensitivity and specificity is 95% and 90% respectively, in the fourth 5-minute interval (15.1 minutes–20 minutes) that preceded the onset of an arrhythmia event. Such results imply that the fourth 5-minute interval would be the best time to perform prediction.

6 January 2021 in Electronics
Verified
Journal Article
Open access
PDF file
Khaleel HusainKhaleel Husain
Khaleel Husain
MZMohd Soperi Mohd Zahid
Mohd Soperi Mohd Zahid
Shahab Ul HassanShahab Ul Hassan
Shahab Ul Hassan
SHSumayyah Hasbullah
Sumayyah Hasbullah
Satria MandalaSatria Mandala
Satria Mandala
It is well-known that cardiovascular disease is one of the major causes of death worldwide nowadays. Electrocardiogram (ECG) sensor is one of the tools commonly used by cardiologists to diagnose and detect signs of heart disease with their patients. Since fast, prompt and accurate interpretation and decision is important in saving the life of patients from sudden heart attack or cardiac arrest, many innovations have been made to ECG sensors. However, the use of traditional ECG sensors is still prevalent in the clinical settings of many medical institutions. This article provides a comprehensive survey on ECG sensors from hardware, software and data format interoperability perspectives. The hardware perspective outlines a general hardware architecture of an ECG sensor along with the description of its hardware components. The software perspective describes various techniques (denoising, machine learning, deep learning, and privacy preservation) and other computer paradigms used in the software development and deployment for ECG sensors. Finally, the format interoperability perspective offers a detailed taxonomy of current ECG formats and the relationship among these formats. The intention is to help researchers towards the development of modern ECG sensors that are suitable and approved for adoption in real clinical settings.

27 February 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Satria MandalaSatria Mandala
Satria Mandala
Annisa Rizki Pratiwi WibowoAnnisa Rizki Pratiwi Wibowo
Annisa Rizki Pratiwi Wibowo
AAAdiwijaya Adiwijaya
Adiwijaya Adiwijaya
SSSuyanto Suyanto
Suyanto Suyanto
MZMohd Soperi Mohd Zahid
Mohd Soperi Mohd Zahid
ARArdian Rizal
Ardian Rizal
This research studies the effects of both Daubechies wavelet basis function (DWBF) and decomposition level (DL) on the performance of detecting atrial fibrillation (AF) based on electrocardiograms (ECGs). ECG signals (consisting of 23 AF data and 18 normal data from MIT-BIH) were decomposed at various levels using several types of DWBF to obtain four wavelet coefficient features (WCFs), namely, minimum (min), maximum (max), mean, and standard deviation (stdev). These features were then classified to detect the presence of AF using a support vector machine (SVM) classifier. Distribution of training and testing data for the SVM uses the 5-fold cross-validation (CV) principle to produce optimum detection performance. In this study, AF detection performance is measured and analyzed based on accuracy, sensitivity, and specificity metrics. The results of the analysis show that accuracy tends to decrease with increases in the decomposition level. In addition, it becomes stable in various types of DWBF. For both sensitivity and specificity, the results of the analysis show that increasing the decomposition level also causes a decrease in both sensitivity and specificity. However, unlike the accuracy, changing the DWBF type causes both two metrics to fluctuate over a wider range. The statistical results also indicate that the highest AF accuracy detection (i.e., 94.17%) is obtained at the Daubechies 2 (DB2) function with a decomposition level of 4, whereas the highest sensitivity, 97.57%, occurs when the AF detection uses DB6 with a decomposition level of 2. Finally, DB2 with decomposition level 4 results in 96.750% for specificity. The finding of this study is that selecting the appropriate DL has a more significant effect than DWBF on AF detection using WCF.

15 June 2023 in BioMedInformatics
Verified
Journal Article
Open access
PDF file
SHSumayyah Hasbullah
Sumayyah Hasbullah
MZMohd Soperi Mohd Zahid
Mohd Soperi Mohd Zahid
Satria MandalaSatria Mandala
Satria Mandala
Myocardial Infarction (MI) is the death of the heart muscle caused by lack of oxygenated blood flow to the heart muscle. It has been the main cause of death worldwide. The fastest way to detect MI is by using an electrocardiogram (ECG) device, which generates graphs of heartbeats morphology over a certain period of time. Patients with MI need fast intervention as delay will lead to worsening heart conditions or failure. To improve MI diagnosis, much research has been carried out to come up with a fast and reliable system to aid automatic MI detection and prediction from ECG readings. Recurrent Neural Network (RNN) with memory has produced more accurate results in predicting time series problems. Convolutional neural networks have also shown good results in terms of solving prediction problems. However, CNN models do not have the capability of remembering temporal information. This research proposes hybrid models of CNN and RNN techniques to predict MI. Specifically, CNN-LSTM and CNN-BILSTM models have been developed. The PTB XL dataset is used to train the models. The models predict ECG input as representing MI symptoms, healthy heart conditions or other cardiovascular diseases. Deep learning models offer automatic feature extraction, and our models take advantage of automatic feature extraction. The other superior models used their own feature extraction algorithm. This research proposed a straightforward architecture that depends mostly on the capability of the deep learning model to learn the data. Performance evaluation of the models shows overall accuracy of 89% for CNN LSTM and 91% for the CNN BILSTM model.

30 October 2020 in The Journal of Supercomputing
Verified
Journal Article
Closed access
PDF file
JKJenni Kommineni
Jenni Kommineni
Satria MandalaSatria Mandala
Satria Mandala
MSMohd Shahrizal Sunar
Mohd Shahrizal Sunar
PCParvathaneni Midhu Chakravarthy
Parvathaneni Midhu Chakravarthy