Ilhan Yu

Mr. Ilhan Yu


Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
Girdhari RijalGirdhari Rijal
Girdhari Rijal
JWJing Wang
Jing Wang
IYIlhan Yu
Ilhan Yu
DGDavid Gang
David Gang
Roland ChenRoland Chen
Roland Chen
Weimin LiWeimin Li
Weimin Li
Porcine mammary fatty tissues represent an abundant source of natural biomaterial for generation of breast-specific extracellular matrix (ECM). Here we report the extraction of total ECM proteins from pig breast fatty tissues, the fabrication of hydrogel and porous scaffolds from the extracted ECM proteins, the structural properties of the scaffolds (tissue matrix scaffold, TMS), and the applications of the hydrogel in human mammary epithelial cell spatial cultures for cell surface receptor expression, metabolomics characterization, acini formation, proliferation, migration between different scaffolding compartments, and in vivo tumor formation. This model system provides an additional option for studying human breast diseases such as breast cancer.

Verified
Journal Article
Open access
PDF file
IYIlhan Yu
Ilhan Yu
Roland ChenRoland Chen
Roland Chen
Developing a high-efficiency manufacturing system for personalized medicine plays an important role in increasing the feasibility of personalized medication. The purpose of this study is to investigate the feasibility of a new extrusion-based fabrication process for personalized drugs with a faster production rate. This process uses two syringe pumps with a coaxial needle as an extruder, which extrudes two materials with varying ratios into a capsule. The mixture of hydrogel, polyethylene glycol (PEG), hydroxypropyl methylcellulose, poly acrylic acid and the simulated active pharmaceutical ingredient, Aspirin, was used. To validate the method, samples with different ratios of immediate release (IR) and sustained release (SR) mixtures were fabricated. The results of a dissolution test show that it is feasible to control the release profile by changing the IR and SR ratio using this fabrication setup. The fabrication time for each capsule is about 20 seconds, which is significantly faster than the current 3D printing methods. In conclusion, the proposed fabrication method shows a clear potential to step toward the feasibility of personalized medication.

29 March 2021 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
IYIlhan Yu
Ilhan Yu
Roland ChenRoland Chen
Roland Chen
Coaxial extrusion is a commonly used process to manufacture tubular structures to mimic vascular systems in 3D bioprinting. In this study, the stability of coaxial extrusion of a non-Newtonian material, Pluronic F127, is investigated. The extrusion process is considered stable when the extrudate form a core-annular structure. When it is unstable, dripping or jetting of the inner fluid is observed. In this study, the effects of the viscosity ratio, flowrate ratio, and the non-Newtonian behaviors on the stability of the coaxial extrusion process are investigated experimentally and numerically. The results show that all three factors can affect the stability of the process. When the ratio of viscosities increases, the process becomes unstable. The extrusion process tends to be stable when the flowrate of the outer fluid is much higher than that of the inner fluid. When the overall flowrate decreases, due to the non-Newtonian fluid behavior, the extrusion process can become unstable. This study shows the interconnected relationship between viscosity, flowrate, and non-Newtonian fluid behaviors and their effects on the stability of the coaxial extrusion process. The non-Newtonian flow behavior needs to be considered when studying or using coaxial extrusion. This study also provides a guiding principle on how to alter extrusion parameters in order to achieve the desired flow pattern.

14 May 2020 in Journal of Manufacturing Science and Engineering
Verified
Journal Article
Closed access
PDF file
IYIlhan Yu
Ilhan Yu
SGSamantha Grindrod
Samantha Grindrod
Roland ChenRoland Chen
Roland Chen
Tubular structures of the hydrogel are used in a variety of applications such as delivering nutrient supplies for 3D cell culturing. The wall thickness of the tube determines the delivery rate. In this study, we used the coaxial extrusion process to fabricate tubular structures with varying wall thicknesses using a thermal-crosslinking hydrogel, gellan gum (GG). The objectives of this study are to investigate the thermal extrusion process of GG to form tubular structures, the range of achievable wall thickness, and a possibility to form tubular structures with closed ends to encapsulate fluid or drug inside the tube. The wall thickness is controlled by changing the relative flow velocity of the inner needle (phosphate-buffered saline, PBS) to the outer needle, while keeping the velocity of outer needles (GG) constant. Two pairs of coaxial needles were used which are 18-12 gauge (G) and 20-12G. The controllable wall thickness ranges from 0.618 mm (100% relative velocity) to 0.499 mm (250%) for 18-12G and from 0.77 mm (80%) to 0.69 (200%) for 20-12G. Encapsulation is possible in a smaller range of flow velocities in both needle combinations. A finite element model was developed to estimate the temperature distribution and the wall thickness. The model is found to be accurate. The dynamic viscosity of GG determines the pressure equilibrium and the range of achievable wall thickness. Changing the inner needle size or the flow velocity both affect the heat exchange and thus the temperature-dependent dynamic viscosity.