A novel surface plasmon resonance (SPR) biosensor based on Ag-Au bimetallic films with a hybrid structure of blue phosphorene (BlueP)/transition metal dichalcogenides (TMDCs) and graphene is presented. In order to improve the sensitivity, the thickness of silver and gold films is optimized to achieve minimum reflectivity and an adequate level of sensitivity; further, sensitivity for the monolayer ${\rm BlueP}/{{\rm MoS}_2}$ and graphene structure is enhanced by 19.73%, with respect to a traditional sensor. Besides, the effect of layers of different Blue/TMDCs heterostructures to the sensitivity of the SPR biosensor is investigated, and the highest sensitivity with 335.4°/RIU for the bilayer ${\rm BlueP}/{{\rm WS}_2}$ is obtained. Furthermore, distributions of the electric field and the changes of resonance angle to the refractive index of the sensing medium and prism in the visible regime are illustrated at optimal configuration. In virtue of highly sensitive characteristics, the proposed sensor structure will be a much better option to be employed for further biological detection.
In this paper, a novel method to determine the thickness of thin metal film is put forward which uses Surface Plasmon Resonance (SPR) phase detection method. The relations between the metal film thickness and the phases of the transverse magnetic (TM) and transverse electric (TE) polarization of the reflected light are shown in the simulation results. By recording the interference patterns which contain the information of the phase differences in the experiments, the values of thickness are calculated. Both of the theoretical analysis and experimental results indicate that the approach presented is feasible and reliable. Thus, it is possible to use the method of phase detection to determine the thickness of thin metal films within 100nm in SPR prism couplers directly with nanometer resolution.
24 September 2019 in Journal of Physics D: Applied Physics
Weak measurement is an important measurement method in quantum measurement, which has been widely used in detecting the photonic spin Hall effect (PSHE). The models of weak measurement for detecting PSHE have been derived in the frame of quantum mechanics. However, the existing models still have some drawbacks. For example, they are not suitable for the case where the reflection interface is composed of absorption medium, or the case when the reflection is in total internal reflection. A new improved model of weak measurement for detecting the PSHE of reflected Gaussian beam is derived in this article. The improved model is not derived in the framework of quantum mechanics, but is derived in the framework of classical optics which is easier to understand. In comparison to the existing models, the new improved model we derived no longer has the above restrictions. It is suitable for both the absorbent and non-absorbent medium interfaces, and is also suitable for both the partial and total internal reflection. Furthermore, the improved model is verified by experiments and the experimental results are in good agreement with the theoretical results. It is believed that this improved new model will help researchers to study the PSHE more widely and may provide more ways for the precise measurement of physical parameters. In addition, the derivation way based on classical optics theory also provides a new path to establish the quantum weak measurement models.
1 December 2020 in Review of Scientific Instruments
In this paper, a novel method of film thickness measurement based on weak measurements is proposed by analyzing the quantitative relationship between film thickness and the weak measurement amplified shift of the photonic spin Hall effect, and the corresponding measurement system is established to verify it through experiments. This method can measure the thickness of an arbitrary dielectric film with nanometer resolution. The theoretical analysis and experimental results show that the method is reasonable, feasible, and reliable, and the structure of the measurement system is simple, easy to operate, and easy to assemble into a prototype instrument. The measurement model and method provide not only a new way for the measurement of thin film thickness but also an important reference for the precise measurement of other optical interface parameters.
A modified model for photonic spin Hall effect (PSHE) when Gaussian beam is reflected from a dielectric interface is derived. Compared with the former models that generally have great limitations (such as only applicable to p- and s-polarization; or the approximate p-polarization; or invalid around the Brewster angle), the modified model we derived does not have the above limitations, which can be suitable for arbitrary linear incident polarization and arbitrary angle of incidence. Furthermore, the modified model is verified by experiments and the experimental results are in good agreement with the theoretical results.