View All Publications
1 January 2006 in Physics of Fluids
Verified
Journal Article
Closed access
PDF file
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
DMDemetri S. Mathioulakis
Demetri S. Mathioulakis
STSokrates G. Tsangaris
Sokrates G. Tsangaris
The development of a theoretical model of valveless pumping and its numerical solution is presented in this work, applied for the case of a closed hydraulic loop, consisting of a soft and a rigid tube. A periodic compression and decompression of the soft tube causes a unidirectional flow, under certain conditions. The integration of the governing flow equations (continuity and momentum), over the tube cross-sectional area results in a quasi-one-dimensional unsteady model. A system of nonlinear partial differential equations of the hyperbolic type is solved numerically, employing three finite difference schemes: Lax-Wendroff, MacCormack, and Dispersion Relation Preserving, the last being the most accurate one. When the excitation takes place far from the midlength of the soft tube, a phase difference between the pressures at the two edges of each tube is developed, being in advance the one that is closer to the excitation area. Increasing the tube occlusion or the length of the excited part of the loop the mean flow rate increases and maximizes at the natural frequency of the loop. The direction of the maximum mean flow rate, for a given tube occlusion, is from the excitation area toward the edge of the stiff tube, which is located closer to the excitation area. Varying the excitation frequency both above and below the resonance frequency, local flow rate extremes appear, manifesting the complex character of the valveless pumping phenomenon.

1 October 2018 in Journal of Biomechanics
Verified
Journal Article
Closed access
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
IKIoannis Karathanasis
Ioannis Karathanasis
IKIlias Kouerinis
Ilias Kouerinis
DADimitrios C. Angouras
Dimitrios C. Angouras
ALAndreas Lazaris
Andreas Lazaris
DSDimitrios Sokolis
Dimitrios Sokolis

19 August 2015 in Scientific Reports
Verified
Journal Article
Open access
AVAimilia Varela
Aimilia Varela
Christina PiperiChristina Piperi
Christina Piperi
FSFragiska Sigala
Fragiska Sigala
GAGeorge Agrogiannis
George Agrogiannis
CDConstantinos H Davos
Constantinos H Davos
Athanasios G. PapavassiliouAthanasios G. Papavassiliou
Athanasios G. Papavassiliou
Atherosclerotic plaque formation is associated with irregular distribution of wall shear stress (WSS) that modulates endothelial function and integrity. Polycystins (PC)-1/-2 constitute a flow-sensing protein complex in endothelial cells, able to respond to WSS and induce cell-proliferation changes leading to atherosclerosis. An endothelial cell-culture system of measurable WSS was established to detect alterations in PCs expression under conditions of low- and high-oscillatory shear stress in vitro. PCs expression and p53 activation as a regulator of cell proliferation were further evaluated in vivo and in 69 advanced human carotid atherosclerotic plaques (AAPs). Increased PC-1/PC-2 expression was observed at 30–60 min of low shear stress (LSS) in endothelial cells. Elevated PC-1 expression at LSS was followed by p53 potentiation. PCs immunoreactivity localizes in areas with macrophage infiltration and neovascularization. PC-1 mRNA and protein levels were significantly higher than PC-2 in stable fibroatherotic (V) and unstable/complicated (VI) AAPs. Elevated PC-1 immunostaining was detected in AAPs from patients with diabetes mellitus, dyslipidemia, hypertension and carotid stenosis, at both arteries (50%) or in one artery (90%). PCs seem to participate in plaque formation and progression. Since PC-1 upregulation coincides with p38 and p53 activation, a potential interplay of these molecules in atherosclerosis induction is posed.

1 August 2012 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
Efstratios GeorgakarakosEfstratios Georgakarakos
Efstratios Georgakarakos
AXAntonios Xenakis
Antonios Xenakis
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
GGGeorge S. Georgiadis
George S. Georgiadis
STSokrates Tsangaris
Sokrates Tsangaris
MLMiltos K. Lazarides
Miltos K. Lazarides
Purpose To evaluate the displacement forces acting on an aortic endograft when the iliac limbs are crossed (“ballerina” position). Methods An endograft model was computationally reconstructed based on data from a patient whose infrarenal aortic aneurysm had an endovascular stent-graft implanted with the iliac limbs crossed. Computational fluid dynamics analysis determined the maximum displacement force on the endograft and separately on the bifurcation and iliac limbs. Its analogue model was reconstructed for comparison, assuming the neck, main body, and total length constant but considering the iliac limbs to be deployed in the usual bifurcated mode. Calculations were repeated after developing “idealized” models of both the bifurcated and crossed-limbs endografts with straight main bodies and no neck angulation or curved iliac segments. Results The vector of the total force was directed anterocaudal for both the typical bifurcated and the crossed-limbs configurations, with the forces in the latter slightly reduced and the vertical component accounting for most of the force in both configurations. Idealized crossed-limbs and bifurcated configurations differed only in the force on the iliac limbs, but this difference disappeared in the realistic models. Conclusion Crossing of the iliac limbs can slightly affect the direction of the displacement forces. Although this configuration can exert larger forces on the limbs than in the bifurcated mode, this effect can be blunted by concomitant modifications in the geometry of the main body and other parts of the endograft, making its hemodynamic behavior resemble that of a typically positioned endograft.

6 February 2020 in Proceedings of the Institution of Mechanical Engineers, Part C: Journal of Mechanical Engineering Science
Verified
Journal Article
Closed access
PDF file
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
STSokrates Tsangaris
Sokrates Tsangaris
DMDimitrios Mathioulakis
Dimitrios Mathioulakis
Net flow generation in valveless pumping, met in many physiological applications and recently in micropumping devices, constitutes an open fluid dynamics issue due to the complex interaction between the fluid medium and the flexible walls of the pump. In the context of the present experimental work, the conditions of the net flow generation are examined in a closed-loop horizontal valveless pump, which consists of a rigid and an elastic tube of equal diameters and lengths, and a pincher that forces the liquid within the tube to oscillate at Reynolds and Womersley numbers up to 7800 and 48, respectively. Pinching off as well as at the mid-length of the pump flexible tube, net flow is generated at certain pinching frequencies for which details are presented based on simultaneous recording of the pressure at the two tube junctions, the flow rate and the displacement of the pincher. Pinching off the mid-length of the pump at low pinching frequencies, net flow rate is practically null due to the almost identical pressure waveforms at the tube junctions, which vary in phase with the pincher motion. However, close to the first natural frequency of the hydraulic loop, the reflection of the pressure waves at the tube junctions combined with their increased phase difference cause high axial pressure gradients, which when they increase simultaneously with the squeezing of the tube, net flow rate maximization occurs. Pinching at the flexible tube mid-length area, nonzero net flow rates can also be generated, the sign of which changes when the pincher mid-point crosses the tube mid-length without being nullified.

1 April 2013 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
Efstratios GeorgakarakosEfstratios Georgakarakos
Efstratios Georgakarakos
AXAntonios Xenakis
Antonios Xenakis
Christos ManopoulosChristos Manopoulos
Christos Manopoulos
GGGeorge S. Georgiadis
George S. Georgiadis
STSokrates Tsangaris
Sokrates Tsangaris
MLMiltos Lazarides
Miltos Lazarides
Purpose To compare the hemodynamic behavior between an aortic endograft model in the “crossed-limbs” configuration and the customary bifurcated deployment position under the influence of several geometric factors. Methods A crossed-limbs graft and its analogue model with uncrossed limbs were computationally reconstructed. The displacement forces acting over the entire endograft and at the bifurcation and iliac sites separately were calculated using a fluid structure interaction simulation under a range of specific geometric characteristics, namely, the lateral and anteroposterior (AP) neck angulation, the iliac bifurcation angulation, and the endograft curvature. Results The variations of lateral neck angulation caused a constantly higher total displacement force for the crossed-limbs graft, whereas the force at the bifurcation of the two configurations differed only within a narrow range of 30° to 50°. On the contrary, the displacement force at the iliac site was higher in the crossed-limbs configuration only with lateral neck angulation >50°, reaching its highest value at 70°. The variations of AP neck angulation also caused higher total displacement forces in the crossed-limbs graft. Increasing AP neck angulation values caused generally lower forces at the crossed iliac limbs and higher at its bifurcation, respectively, compared to the uncrossed limbs model. Similarly, the influence of high iliac bifurcation angulation and endograft curvature was associated with slightly elevated forces over the entire crossed-limbs graft and its bifurcation, whereas the opposite held true at the iliac site. Conclusion Apart from minor differentiations due to geometric alterations, the customary bifurcated and crossed-limbs endografts present similar hemodynamic performance. Further clinical studies should be conducted to confirm the clinical applicability of these findings.