Paweł Rynio

Dr. Paweł Rynio

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 June 2019 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PDF file
PRPaweł Rynio
Paweł Rynio
JWJan Witowski
Jan Witowski
JKJakub Kamiński
Jakub Kamiński
JSJakub Serafin
Jakub Serafin
AKArkadiusz Kazimierczak
Arkadiusz Kazimierczak
PGPiotr Gutowski
Piotr Gutowski
Purpose: To demonstrate the feasibility of augmented reality visualization in planning and navigating endovascular aortic repair. Technique: A 77-year-old patient with abdominal aortic aneurysm was treated with endovascular repair. An augmented reality head-mounted display was used during the procedure. The aneurysm and bones were projected as 3-dimensional holograms. The operator controlled the device with gestures and voice commands (movement, rotation, cutting through, and zooming). Moreover, the hologram was placed in front of the angiography monitor and manually registered with fluoroscopy. Conclusion: Augmented reality with holographic rendering is feasible and helpful during endovascular aortic repair. Its routine use could possibly lead to shorter operating time, reduced contrast volume, and lower radiation dose; however, larger studies are required to obtain statistically significant results on the outcomes.

30 July 2018 in Journal of Endovascular Therapy
Verified
Journal Article
Closed access
PRPaweł Rynio
Paweł Rynio
AKArkadiusz Kazimierczak
Arkadiusz Kazimierczak
TJTomasz Jedrzejczak
Tomasz Jedrzejczak
PGPiotr Gutowski
Piotr Gutowski
Purpose: To demonstrate the utility of a 3-dimensional (3D) printed template of the aortic arch in the construction of a fenestrated and scalloped physician-modified stent-graft (PMSG). Case Report: A 73-year-old woman with descending thoracic aneurysm was scheduled for thoracic endovascular aortic repair after being disqualified for open surgery. Computed tomography angiography (CTA) revealed no proximal landing zone as the aneurysm began from the level of the left subclavian artery, so a fenestrated/scalloped PMSG was planned. To facilitate accurate placement of the openings in the graft, a 3D printed aortic arch template was prepared from the CTA data and gas sterilized. In the operating room, a Valiant stent-graft was inserted into the 3D printed template and deployed. Using ophthalmic cautery, a fenestration and a scallop were created; radiopaque markers were added. The PMSG was successfully deployed with no discrepancy between the openings and the target vessels. Conclusion: A 3D printed aortic arch template facilitates handmade fenestrations and scallops in PMSGs and may improve accuracy and quality.

Verified
Journal Article
Open access
PDF file
PRPaweł Rynio
Paweł Rynio
KMKatarzyna Mańkowska
Katarzyna Mańkowska
ŁWŁukasz Wójcik
Łukasz Wójcik
BGBartłomiej Grygorcewicz
Bartłomiej Grygorcewicz
AKArkadiusz Kazimierczak
Arkadiusz Kazimierczak
MKMiłosz Kawa
Miłosz Kawa
Three-dimensionally-printed aortic templates are increasingly being used to aid in the modification of stent grafts in the treatment of urgent, complex aortic disorders, often of an emergency nature. The direct contact between the aortic template and the stent graft implies the necessity of complete sterility. Currently, the efficacy of sterilizing aortic templates and the effect of sterilization on the geometry of tubular aortic models are unknown. A complex case of aortic arch dissection was selected to prepare a 3D-printed aortic arch template, which was then manufactured in six popular printing materials: polylactic acid (PLA), nylon, polypropylene (PP), polyethylene terephthalate glycol (PETG), and a rigid and flexible photopolymer resin using fused deposition modeling (FDM) and stereolithography (SLA). The 3D models were contaminated with Geobacillus stearothermophilus broth and Bacillus atrophaeus. The sterilization was performed using three different methods: heat (105 °C and 121 °C), hydrogen peroxide plasma, and ethylene oxide gas. Before and after sterilization, the aortic templates were scanned using computed tomography to detect any changes in their morphology by comparing the dimensions. All sterilization methods were effective in the elimination of microorganisms. Steam sterilization in an autoclave at 121 °C caused significant deformation of the aortic templates made of PLA, PETG, and PP. The other materials had stable geometries, and changes during mesh comparisons were found to be submillimeter. Similarly, plasma, gas, and heat at 105 °C did not change the shapes of aortic templates observed macroscopically and using mesh analysis. All mean geometry differences were smaller than 0.5 mm. All sterilization protocols tested in our study were equally effective in destroying microorganisms; however, differences occurred in the ability to induce 3D object deformation. Sterilization at high temperatures deformed aortic templates composed of PLA, PETG, and PP. This method was suitable for nylon, flexible, and rigid resin-based models. Importantly, plasma and gas sterilization were appropriate for all tested printing materials, including PLA, PETG, PP, nylon, flexible and rigid resins. Moreover, sterilization of all the printed models using our novel protocol for steam autoclaving at 105 °C was also 100% effective, which could represent a significant advantage for health centers, which can therefore use one of the most popular and cheap methods of medical equipment disinfection for the sterilization of 3D models as well.

1 December 2019 in Journal of Vascular Surgery
Verified
Journal Article
Closed access
AKArkadiusz Kazimierczak
Arkadiusz Kazimierczak
PRPaweł Rynio
Paweł Rynio
TJTomasz Jędrzejczak
Tomasz Jędrzejczak
KMKrzysztof Mokrzycki
Krzysztof Mokrzycki
RSRabih Samad
Rabih Samad
PGPiotr Gutowski
Piotr Gutowski

1 February 2022 in Quantitative Imaging in Medicine and Surgery
Verified
Journal Article
Open access
PDF file
PRPaweł Rynio
Paweł Rynio
MWMaciej Wojtuń
Maciej Wojtuń
ŁWŁukasz Wójcik
Łukasz Wójcik
MKMiłosz Kawa
Miłosz Kawa
AFAleksander Falkowski
Aleksander Falkowski
AKArkadiusz Kazimierczak
Arkadiusz Kazimierczak
The accuracy and reliability of 3D printed aortic templates: a comprehensive three-dimensional analysis Pawel Rynio, Maciej Wojtuń, Łukasz Wójcik, Miłosz Kawa, Aleksander Falkowski, Piotr Gutowski, Arkadiusz Kazimierczak

13 April 2022 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
PRPaweł Rynio
Paweł Rynio
TJTomasz Jedrzejczak
Tomasz Jedrzejczak
ARAnita Rybicka
Anita Rybicka
RMRoss Milner
Ross Milner
PGPiotr Gutowski
Piotr Gutowski
AKArkadiusz Kazimierczak
Arkadiusz Kazimierczak
The goal of this study was to describe the surgical results of physician-modified endografts (PMEG) utilizing a 3D aortic template in a center with no prior experience in complex endovascular aortic repairs. Forty-three patients underwent physician-modified graft stent implantation using a 3D aortic model. The inclusion criteria were juxtarenal and suprarenal aortic aneurysms, type IV thoracoabdominal aneurysms, and type IA endoleak after endovascular aortic repair. In asymptomatic patients, the diameter threshold for aneurysm repair was 5.5 cm in males and 5.0 cm in females. 3D aortic templates were prepared from the patient’s computed tomography angiography scans and sterilized before use in the operating suite. Forty-three stent grafts were modified with the use of a 3D printing template. A total of 162 reinforced fenestrations (37 celiac, 43 right renal, 39 left renal, 43 superior mesenteric) with a mean of 3.8 per patient were performed. All PMEGs had a posterior reducing-diameter tie and a preloaded guidewire. The mean modification time was 86 ± 12 min. The mean follow-up was 14 ± 12 months. The 30-day mortality was 12%. During the follow-up period, the patency rate was 95% per the superior mesenteric artery, 93% per right renal artery, 95% per left renal artery, and 89% per celiac trunk. Twelve (28%) patients had endoleak, of which type I or III was present in 5 (12%) patients, and type II in 7 (16%). 3D printing can be successfully integrated into the physician’s everyday practice of stent graft modification. However, the use of this approach in centers without experience performing complex aortic procedures results in worse surgical metrics than those previously reported.